Measurement of arterial blood flow by Doppler ultrasound
The DOI matches its Crossref record; 232 of the 232 references it cites were found in a registry or an index.
Abstract
A review is given of quantitative techniques and clinical applications of arterial Doppler ultrasound. The currently available Doppler equipment of stand-alone continuous wave and pulsed wave units, duplex systems and colour flow systems is briefly described. Doppler ultrasound can be divided into procedures concerned with waveform analysis, volume flow measurement and more recently colour flow imaging. Arterial Doppler waveform analysis is considered for a number of areas including carotid, lower limb, renal and renal transplant, obstetrics, adult cerebral, neonatal cerebral, and tumour studies. Using a duplex scanner volume flow in arteries can be measured from estimates of vessel cross sectional area, mean Doppler frequency and beam-vessel angle. The errors associated with each of these measurements is discussed, and reports of experimentally determined in vivo accuracy of volume flow measurements made using this technique are considered. Other volume flow measurement techniques including the promising attenuation compensation method are also explored.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Items 201–232 of 232
The time-distance recorder as a means of improving the accuracy of fetal blood flow measurements
Struyk, P. C., Pijpers, L., Wladimiroff, J. W., Lotgering, F. K., Tonge, M., & Bom, N. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90009-2 · Cited by 14
The effects of placental site on the arcuate artery flow velocity waveform.
Chambers, S. E. J., Johnstone, F. D., Muir, B. B., Hoskins, P. R., Haddad, N. G., & McDicken, W. N. (1988) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1988.7.12.671 · Cited by 14
Self-citationUmbilical Artery Blood Flow Characteristics in Normal and Growth-Retarded Fetuses
ERSKINE, R. L. A., & RITCHIE, J. W. K. (1986) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-198604000-00003 · Cited by 13
Factors affecting the continuous wave Doppler spectrum for the diagnosis of carotid arterial disease
Morin, J., Johnston, K. W., & Law, Y. F. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90138-x · Cited by 13
van Eyck, J., Wladimiroff, J. W., Noordam, M. J., van den Wijngaard, J. A. G. W., & Prechtl, H. F. R. (1988) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1988.tb12799.x · Cited by 13
DOPPLER UTEROPLACENTAL WAVEFORMS
Pearce, J. M., McParland, P., Campbell, S. C., Vyas, S. K., Bewley, S., Fairlie, F., Walker, J. J., Mathers, A. M., Cameron, A. D., Hanretty, K. P., et al. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92108-3 · Cited by 13
Noninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning
Kohler, T. R., Zierler, R. E., Martin, R. L., et al. (1986) · Journal of Vascular Surgery · doi:10.1067/mva.1986.avs0040450 · Cited by 13
Cerebral Blood Flow Measurements in Clinical Neurosurgery
Teasdale, G. M., & Mendelow, D. A. (1981) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1981.40 · Cited by 12
Brar, H. S., Medearis, A. L., DeVore, G. R., & Platt, L. D. (1989) · Journal of diagnostic medical sonography · doi:10.1177/875647938900500114 · Cited by 12
The accuracy of duplex scanning in the evaluation of early carotid disease
Hames, T. K., Ratliff, D. A., Humphries, K. N., Gazzard, V. M., Birch, S. J., & Chant, A. D. B. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90075-4 · Cited by 11
Lewis, R., Padayachee, T. S., & Gosling, R. G. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90058-9 · Cited by 11
Baker, A. R., Prytherch, D. R., Evans, D., & BELL, P. R. F. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90219-x · Cited by 11
Examination of the placental circulation by Doppler ultrasound.
Redman, C. W. G. (1989) · BMJ · doi:10.1136/bmj.298.6674.621 · Cited by 10
Hoskins, P. R., McDicken, W. N., Johnstone, F. D., White, G. M., Haddad, N. G., & Chambers, S. E. J. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90126-3 · Cited by 10
Self-citationNoninvasive Versus Invasive Doppler Renal Blood Velocity and Flow Measurements
Greene, E. R., Avasthi, P. S., Voyles, W. F., & Seigel, R. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325714 · Cited by 9
LaPlace transform analysis of femoral artery doppler signals: The state of the art
Baker, J. D., Skidmore, R., & Cole, S. E. A. (1989) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(89)90127-0 · Cited by 9
Detection of Carotid Artery Disease by Duplex Ultrasound
Cardullo, P. A., Cutler, B. S., & Wheeler, H. B. (1986) · Journal of diagnostic medical sonography · doi:10.1177/875647938600200202 · Cited by 8
Analysis of femoral artery Doppler signals by LaPlace transform damping method
Baker, J. D., Machleder, H. I., & Skidmore, R. (1984) · Journal of Vascular Surgery · doi:10.1067/mva.1984.avs0010520 · Cited by 8
Changes in doppler waveforms can predict pressure reduction across internal carotid artery stenoses
Sillesen, H. H., & Schroeder, T. V. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90021-x · Cited by 7
Reversed ophthalmic doppler signal: A study of its significance
Strik, F. (1984) · Clinical Neurology and Neurosurgery · doi:10.1016/0303-8467(84)90272-5 · Cited by 7
Baker, A. R., Evans, D. H., Prytherch, D. R., & Bell, P. R. F. (1986) · British journal of surgery · doi:10.1002/bjs.1800730714 · Cited by 7
Investigation of doppler waveforms in porcine renal allografts: Doppler-pathologic correlation
Piccirillo, M., Taylor, K. J. W., Flye, M. W., Burns, P. N., True, L. D., & Weltin, G. G. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90177-9 · Cited by 7
Padayachee, T. S., Lewis, R., & Gosling, R. G. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90057-7 · Cited by 7
Mulders, L. G. M., Jongsma, H. W., & Hein, P. R. (1989) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(89)90175-5 · Cited by 6
Direct measurements of fetal cerebral blood-flow velocity with duplex Doppler ultrasound
Lang, G. D., Levene, M. I., Dougall, A., Shortland, D. B., & Evans, D. (1988) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(88)90159-1 · Cited by 5
Quantitation of internal carotid artery stenosis by ocular plethysmography.
Gg, J., & Ef, B. (1975) · PubMed · Cited by 5
Design of a continuous-wave Doppler ultrasonic flowmeter for perivascular application
Richardson, P. C. A., Stevens, A. L., Cowan, D., Calil, S. J., & Roberts, V. C. (1987) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447335 · Cited by 4
A new screening technique for renal artery occlusive disease.
Cs, N., Rittgers, S. E., & Rw, B. (1984) · PubMed · Cited by 4
Design of a continuous-wave Doppler ultrasonic flowmeter for perivascular application
Cowan, D., Stevens, A. L., & Roberts, V. C. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442258 · Cited by 4
Validity of the transfer function model of the human arterial system of the lower limb in man
Law, Y. C., Graham, J., Cotton, L., & Roberts, V. C. (1984) · Medical and Biological Engineering and Computing · doi:10.1007/bf02443867 · Cited by 2
Antenatal screening with umbilical artery Doppler ultrasonography: Authors' reply
Beattie, R. B., & Dornan, J. (1989) · BMJ · doi:10.1136/bmj.298.6680.1097-b · Cited by 2
Doppler Ultrasound in the Assessment of Cerebrovascular Ischaemia
Sheldon, C. D. (1985) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 2
Research works printed but not linked: 11
- Blackshear W M, 1979, Surgery, 86, 698
- Bone G E, 1976, Surgery, 79, 577
- Brar H S, 1988, Obstet. Gynecol., 72, 607
- Campbell S, 1986, Obstet. Gynecol., 68, 649
- Johnstone F D, 1989, Br. Med. J., 298, 1097
- Lo Gerfo F W, 1974, Surgery, 76, 723
- Norris C S, 1984, Curr. Surg., 41, 83
- Roederer G O, 1982, J. Cardiovasc. Ultrasonog., 1, 373
- Roederer G O, 1984, Bruit., 8, 174
- Taylor K, 1988, J. Ultrasound Med., 7, 563
- Woo J S K, 1987, Obstet. Gynecol., 70, 613
Cited by
Measuring cerebrovascular reactivity: what stimulus to use?
Fierstra, J., Sobczyk, O., Battisti‐Charbonney, A., Mandell, D. M., Poublanc, J., Crawley, A. P., Mikulis, D. J., Duffin, J., & Fisher, J. A. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.259150 · Cited by 318
“widespread confidence in this approach, a fixed inspired fractional concentration of CO2 does not produce a fixed related Pa,CO2 , but one that varies both between subjects and within the same subject over time (Hoskins, 1990; Prisman et al. 2008).”
BackgroundMethodSchöning, M., Walter, J., & Scheel, P. (1994) · Stroke · doi:10.1161/01.str.25.1.17 · Cited by 299
Rådegran, G. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.4.1383 · Cited by 297
A wall-less vessel phantom for Doppler ultrasound studies
Rickey, D. W., Picot, P. A., Christopher, D. A., & Fenster, A. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00044-5 · Cited by 235
Scheel, P., Ruge, C., & Schöning, M. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00293-3 · Cited by 206
Metadata
- Authors
- Hoskins, P. R.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- Corresponding author
- Hoskins, P R
- ORCID
- Hoskins, P R
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1990-02
- Volume
- 11
- Issue
- 1
- Pages
- 1-26
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2080576241
- Semantic Scholar
- 88ba39f52a356f17f61a53a623ca311f68fa1261
- Cited by
- 109
- References
- 230
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 5 · 2022: 6 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 2 · 2016: 1 · 2015: 2 · 2013: 7 · 2012: 5
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Physics and Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Keywords
- arterial blood flow, Doppler ultrasound, volumetric flow measurement, waveform analysis, duplex ultrasound, colour flow imaging, carotid artery, lower limb arteries, renal artery, kidney transplantation, cerebral blood flow, tumour blood flow, attenuation compensation, measurement accuracy, Doppler shift
- MeSH terms
- Adult, Arteries, Blood Flow Velocity, Color, Female, Humans, Infant, Newborn, Ultrasonography, Ultrasonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.