Measurement of arterial blood flow by Doppler ultrasound
The DOI matches its Crossref record; 232 of the 232 references it cites were found in a registry or an index.
Abstract
A review is given of quantitative techniques and clinical applications of arterial Doppler ultrasound. The currently available Doppler equipment of stand-alone continuous wave and pulsed wave units, duplex systems and colour flow systems is briefly described. Doppler ultrasound can be divided into procedures concerned with waveform analysis, volume flow measurement and more recently colour flow imaging. Arterial Doppler waveform analysis is considered for a number of areas including carotid, lower limb, renal and renal transplant, obstetrics, adult cerebral, neonatal cerebral, and tumour studies. Using a duplex scanner volume flow in arteries can be measured from estimates of vessel cross sectional area, mean Doppler frequency and beam-vessel angle. The errors associated with each of these measurements is discussed, and reports of experimentally determined in vivo accuracy of volume flow measurements made using this technique are considered. Other volume flow measurement techniques including the promising attenuation compensation method are also explored.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Transcranial Doppler measurement of middle cerebral artery blood flow velocity: a validation study.
Bishop, C. C., Powell, S., Rutt, D., & Browse, N. L. (1986) · Stroke · doi:10.1161/01.str.17.5.913 · Cited by 795
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Lewis, J. F., Kuo, L. C., Nelson, J. G., Limacher, M. C., & Quinones, M. A. (1984) · Circulation · doi:10.1161/01.cir.70.3.425 · Cited by 733
Baron, J. C., Bousser, M. G., Rey, A., Guillard, A., Comar, D., & Castaigne, P. (1981) · Stroke · doi:10.1161/01.str.12.4.454 · Cited by 724
Fetal umbilical artery flow velocity waveforms and placental resistance: pathological correlation
GILES, W. B., TRUDINGER, B. J., & BAIRD, P. J. (1985) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb01045.x · Cited by 724
Sundt, T. M., Sharbrough, F. W., Piepgras, D. G., Kearns, T. P., Messick, J. M., & Oʼfallon, W. M. (1982) · Survey of Anesthesiology · doi:10.1097/00132586-198226040-00005 · Cited by 718
Evaluation of cerebrovascular spasm with transcranial Doppler ultrasound
Aaslid, R., Huber, P., & Nornes, H. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.60.1.0037 · Cited by 681
Noninvasive Doppler determination of cardiac output in man. Clinical validation.
Huntsman, L. L., Stewart, D. K., Barnes, S. R., Franklin, S. B., Colocousis, J. S., & Hessel, E. A. (1983) · Circulation · doi:10.1161/01.cir.67.3.593 · Cited by 595
NEW DOPPLER TECHNIQUE FOR ASSESSING UTEROPLACENTAL BLOOD FLOW
Campbell, S., Griffin, D. R., Pearce, J. M., Diaz-Recasens, J., Cohen-Overbeek, T. E., Willson, K., & Teague, M. J. (1983) · The Lancet · doi:10.1016/s0140-6736(83)91970-0 · Cited by 574
Research works printed but not linked: 11
- Blackshear W M, 1979, Surgery, 86, 698
- Bone G E, 1976, Surgery, 79, 577
- Brar H S, 1988, Obstet. Gynecol., 72, 607
- Campbell S, 1986, Obstet. Gynecol., 68, 649
- Johnstone F D, 1989, Br. Med. J., 298, 1097
- Lo Gerfo F W, 1974, Surgery, 76, 723
- Norris C S, 1984, Curr. Surg., 41, 83
- Roederer G O, 1982, J. Cardiovasc. Ultrasonog., 1, 373
- Roederer G O, 1984, Bruit., 8, 174
- Taylor K, 1988, J. Ultrasound Med., 7, 563
- Woo J S K, 1987, Obstet. Gynecol., 70, 613
Cited by
Measuring cerebrovascular reactivity: what stimulus to use?
Fierstra, J., Sobczyk, O., Battisti‐Charbonney, A., Mandell, D. M., Poublanc, J., Crawley, A. P., Mikulis, D. J., Duffin, J., & Fisher, J. A. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.259150 · Cited by 318
“widespread confidence in this approach, a fixed inspired fractional concentration of CO2 does not produce a fixed related Pa,CO2 , but one that varies both between subjects and within the same subject over time (Hoskins, 1990; Prisman et al. 2008).”
BackgroundMethodSchöning, M., Walter, J., & Scheel, P. (1994) · Stroke · doi:10.1161/01.str.25.1.17 · Cited by 299
Rådegran, G. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.4.1383 · Cited by 297
A wall-less vessel phantom for Doppler ultrasound studies
Rickey, D. W., Picot, P. A., Christopher, D. A., & Fenster, A. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00044-5 · Cited by 235
Scheel, P., Ruge, C., & Schöning, M. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00293-3 · Cited by 206
Oglat, A., Matjafri, M., Suardi, N., Oqlat, M., Abdelrahman, M., & Oqlat, A. (2018) · Journal of Medical Ultrasound · doi:10.4103/jmu.jmu_11_17 · Cited by 190
“The device then calculates the volume flow automatically.[17,31] However, the expression is generally utilized by indicating clinicians when ordering a scanning with the spectral Doppler effect, which mechanically would be further precisely termed as a triplex Doppler since it includes all of gray-scale (B-scan), colo…”
Raine-Fenning, N. J. (2004) · Human Reproduction · doi:10.1093/humrep/deh056 · Cited by 179
“blood flow within subendometrial vessels (Kupesic and Kurjak, 1993; Sladkevicius et al., 1993; Achiron et al., 1995; Tan et al., 1996) are limited by their selection of individual vessels and the assumption that they are representative of the subendometrium as a whole ( Hoskins, 1990 ).”
BackgroundBrachial and femoral artery blood flow in cirrhosis: Relationship to kidney dysfunction,
Maroto, A. (1993) · Hepatology · doi:10.1016/0270-9139(93)90153-e · Cited by 161
Spano, V. R., Mandell, D. M., Poublanc, J., Sam, K., Battisti‐Charbonney, A., Pucci, O., Han, J. S., Crawley, A. P., Fisher, J. A., & Mikulis, D. J. (2012) · Radiology · doi:10.1148/radiol.12112795 · Cited by 142
“Advances in Knowledge n Applying a standardized CO2 vasodilatory stimulus and monitoring change in blood oxygen level–dependent (BOLD) MR imaging is a practical approach to measuring cerebrovascular reactivity (CVR), an indication of the perfusion reserve, in patients with a wide range of neurovascular conditions. n I…”
InfluentialCorreia, M., Provost, J., Tanter, M., & Pernot, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/23/l48 · Cited by 139
“In clinical practice, the estimation of volumetric flow rates cannot be performed accurately with ultrasound imaging and is currently estimated by indirect measurements including the luminal cross-sectional area and the mean spatial velocity that induce important estimation errors (Hoskins 1990).”
BackgroundGenkins, S. M., SANFILIPPO, F., & Carroll, B. A. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.3.535 · Cited by 126
Age Dependence of Total Cerebral Blood Flow Volume from Childhood to Adulthood
Schöning, M., & Hartig, B. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00007 · Cited by 125
“How ever, Doppler f10wmetry is an operator-bound method and, thus, sensitive even to minor errors (Smith 1984; Gill 1985; Hoskins 1990): deviations of J Cereb Blood Flow Me/ab, Vol. /6, No.5, 1996 0.1 mm in ICA diameter measurement result in er rors in flow volume calculations of �4% (Schoning et…”
MethodInfluentialUrback, A. L., MacIntosh, B. J., & Goldstein, B. I. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.05.003 · Cited by 96
“, 1992; Reiss and Oles, 1996) CO2 Inhalation · Can measure precise amount of gas delivered/expired · Less dependent on subject adherence · Mask can be invasive and uncomfortable for patient · Fixed fraction amount of CO2 inspired does not lead to equal PaCO2 between and within subjects (Hoskins, 1990; Prisman et al.,…”
BackgroundAccuracy of duplex scanning for measurement of arterial volume flow
Zierler, B. K., Kirkman, T. R., Kraiss, L. W., Reiss, W. G., Horn, J. R., Bauer, L. A., Clowes, A. W., & Kohler, T. R. (1992) · Journal of Vascular Surgery · doi:10.1016/0741-5214(92)90159-6 · Cited by 86
Global brain hypoperfusion and oxygenation in amnestic mild cognitive impairment
Liu, J., Zhu, Y., Khan, M. A., Brunk, E., Martin‐Cook, K., Weiner, M. F., Cullum, C. M., Lu, H., Levine, B. D., Diaz‐Arrastia, R., et al. (2014) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.04.507 · Cited by 77
“Under steadystate conditions, TAMV is the most accurate index used for CBF calculation when compared with other methods [26].”
Schöning, M., & Scheel, P. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199605000-00020 · Cited by 78
“It is well known that quantitative flow volume measurements are prone to a range of errors (Smith, 1984; Gill, 1985; Hoskins, 1990): e.g., in the internal carotid artery, errors of lOin angle deter mination, of 0.1 mm in diameter, and of 1 cm/s in T A V measurement result in 3, 4, and 4% deviation…”
BackgroundInfluentialAssessment of umbilical arterial and venous flow using color Doppler
Lees, C. C., Albaigés, G., Deane, C., Parra, M., & Nicolaides, K. H. (1999) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1999.14040250.x · Cited by 71
Functional photoacoustic microscopy of hemodynamics: a review
Liu, C., & Wang, L. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00220-4 · Cited by 72
“Many conventional imaging methods consisting of optical coherence tomography (OCT) [87], ultrasound (US) [88, 89], and laser speckle contrast imaging (LSCI) [90] can satisfy blood flow imaging, but they all suffer from low contrast to blood, low resolution for cellular insight, and low sensitivity because of the surro…”
BackgroundSamaei, S., Sawosz, P. L., Kacprzak, M., Pastuszak, Ż., Borycki, D., & Liebert, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-81448-5 · Cited by 68
“(2) g (1) 2 (ts , τ) = 1+ β|g (1) 1 (ts , τ)| (2), Figure 1.”
BackgroundExercise-induced changes in calcium handling in left ventricular cardiomyocytes
Kemi, O. J. (2007) · Frontiers in bioscience · doi:10.2741/2685 · Cited by 77
“Studies of cardiac function in humans have largely relied upon techniques such as echocardiography and Doppler ultrasound recordings to image cardiac wall motion and flow velocities (9, 10, 15), indirect measures of cardiac output by e.”
MethodFetal whole heart blood flow imaging using 4D cine MRI
Roberts, T. A., van Amerom, J. F. P., Uus, A. U., Lloyd, D. F. A., van Poppel, M. P. M., Price, A. N., Tournier, J., Mohanadass, C. A., Jackson, L. H., Malik, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18790-1 · Cited by 58
Mutch, W. A. C., Ellis, M. J., Ryner, L. N., McDonald, P. J., Morissette, M., Pries, P. J., Essig, M., Mikulis, D. J., Duffin, J., & Fisher, J. A. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00023 · Cited by 57
“Although this technique relies on the administration of a gas containing a fixed fractional concentration of CO2, the resultant effect on PaCO2 has also been found to vary considerably between subjects and within the same subject over serial administrations (28, 29).”
MethodMynard, J. P., & Steinman, D. A. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.11.006 · Cited by 53
Accuracy of Volumetric Flow Rate Measurements
Hoyt, K., Hester, F. A., Bell, R. L., Lockhart, M. E., & Robbin, M. L. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.11.1511 · Cited by 50
Splanchnic and extrasplanchic arterial hemodynamics in patients with cirrhosis
Iwao, T., Oho, K., Sakai, T., Tayama, C., Sato, M., Nakano, R., Yamawaki, M., Toyonaga, A., & Tanikawa, K. (1997) · Journal of Hepatology · doi:10.1016/s0168-8278(97)80318-2 · Cited by 48
Jiang, J., Strother, C. M., Johnson, K. M., Baker, S., Consigny, D., Wieben, O. E., & Zagzebski, J. A. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/015 · Cited by 45
“Ultrasound Doppler (UD) is a noninvasive and cost-effective method to provide blood velocity information (Gill 1985, Hoskins 1990).”
Fundamental sources of error and spectral broadening in Doppler ultrasound signals.
Jones, S. A. (1993) · PubMed · Cited by 45
Brachial and femoral artery blood flow in cirrhosis: Relationship to kidney dysfunction
Maroto, A., Ginès, P., Arroyo, V., Ginés, À., Saló, J., Clària, J., Jiménez, W., Brú, C., Rivera, F., & Rodés, J. (1993) · Hepatology · doi:10.1002/hep.1840170507 · Cited by 44
Prokopiou, P. C., Pattinson, K., Wise, R., & Mitsis, G. (2017) · bioRxiv · doi:10.1016/j.neuroimage.2018.10.084 · Cited by 38
“It has been suggested that the end-tidal partial pressure of CO2 (PETCO2) is a suitable surrogate for PaCO2, and therefore, PETCO2 can be used as the stimulus for CBF (Hoskins, 1990; Mark et al., 2011; Robbins et al., 1990; Wise et al., 2004).”
BackgroundMethodInfluentialMeasurement of Anterior and Posterior Circulation Flow Contributions to Cerebral Blood Flow
Boyajian, R. A., Schwend, R. B., Wolfe, M. M., Bickerton, R., & Otis, S. M. (1995) · Journal of Neuroimaging · doi:10.1111/jon1995511 · Cited by 42
Advances in laser speckle imaging: From qualitative to quantitative hemodynamic assessment
Qureshi, M. M., Allam, N., Im, J., Kwon, H.-S., Chung, E., & Vitkin, I. A. (2023) · Journal of Biophotonics · doi:10.1002/jbio.202300126 · Cited by 41
Blood Flow Characteristics of the Human Lactating Breast
Geddes, D. T., Aljazaf, K. M., Kent, J. C., Prime, D. K., Spatz, D. L., Garbin, C. P., Lai, C. T., & Hartmann, P. E. (2012) · Journal of Human Lactation · doi:10.1177/0890334411435414 · Cited by 37
“Other sources of inaccuracy include the wavelength of the ultrasound system and the angle at which the Doppler measurements are acquired.(31) It can be seen from our measurements that for lactating women the mean velocity is the least variable parameter, and as expected, the cross-sectional area had the greatest varia…”
BackgroundHatab, M. R., Giller, C. A., & Clarke, G. D. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00030-6 · Cited by 36
Soustiel, J. F., Levy, E., Zaaroor, M., Bibi, R., Lukaschuk, S., & Manor, D. (2002) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2002.21.12.1405 · Cited by 35
Extracting arterial flow waveforms from pulse oximeter waveforms
Cook, L. B. (2001) · Anaesthesia · doi:10.1046/j.1365-2044.2001.01986.x · Cited by 32
Pennati, G., Bellotti, M., de Gasperi, C., & Rognoni, G. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.938 · Cited by 32
Blood flow velocity in the common carotid artery in humans during graded exercise on a treadmill
Jiang, Z., Yamaguchi, H., Takahashi, A., Tanabe, S., Utsuyama, N., Ikehara, T., Hosokawa, K., Tanaka, H., Kinouchi, Y., & Miyamoto, H. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00238569 · Cited by 29
“the resistance index (RI) and pulsatility index (PI), which it has been thought may reflect the distal flow resistance of the artery where flow velocity is measured (Beasley et al. 1979; Burns 1987; Hassler et al. 1988; Homburg et al. 1993; Hoskins 1990; Wladimiroff et al. 1986; Woo et al. 1987), changes in CBF during…”
BackgroundMethodChulvi‐Medrano, I., Cortell-Tormo, J. M., Hernández-Sánchez, S., Picón-Martínez, M., & Rolnick, N. D. (2023) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2022-0240 · Cited by 29
Broadband Diffuse Optical Spectroscopic Imaging
Tromberg, B. J., Cerussi, A. E., Chung, S.-H., Tanamai, W., & Durkin, A. F. (2011) · CRC Press eBooks · doi:10.1201/b10951-13 · Cited by 29
Mitchell, J. (2007) · Physiotherapy Theory and Practice · doi:10.1080/09593980701593771 · Cited by 27
“Doppler ultrasonography may be continuouswave (CW) Doppler, pulsed-wave (PW) Doppler, duplex scanning (a combination of B-mode ultrasonography and PW-Doppler), color Doppler (Hoskins, 1990), triplex scanning (duplex scanning combined with color Doppler), or power Doppler (Saunders, 1998).”
BackgroundMethodInfluentialRobertson, J., Leen, E. L. S., Goldberg, J. A., Angerson, W. J., Sutherland, G. R., & McArdle, C. S. (1992) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/13/4/001 · Cited by 27
Matjafri, M., Oglat, A. A., Suardi, N., Oqlat, M., Abdelrahman, M., & Oqlat, A. (2018) · Journal of Medical Ultrasound · doi:10.4103/jmu.jmu_1_17 · Cited by 25
“[67] Measurements utilizing Sephadex particles and blood pointed out no variation in the speckle pattern, or any reliance of this pattern on Sephadex concentration.[71] There was no influence on speckle pattern as an outcome of scattered bulk.”
BackgroundAlexander, A. A., Nazarian, L. N., Capuzzi, D. M., Rawool, N. M., Kurtz, A., & Mastrangelo, M. J. (1998) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1998.17.2.123 · Cited by 25
Raine‐Fenning, N. J. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5321 · Cited by 23
Developments in cardiovascular ultrasound. Part 2: Arterial applications
Hoskins, P. R., Fish, P. J., McDicken, W. N., & MORAN, C. M. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522469 · Cited by 23
Self-citationVolume Measurement of Cerebral Blood Flow: Assessment of Cerebral Circulatory Arrest
Sch�ning, M., Scheel, P., Holzer, M., Fretschner, R., & Will, B. E. (2005) · Transplantation · doi:10.1097/01.tp.0000167994.78078.e6 · Cited by 25
“The accuracy of flow volume measurement depends on a precise assessment of the angle-corrected time-averaged flow velocity (TAV) and the diameter of the vessel (9, 29, 30).”
BackgroundProtein ingestion acutely inhibits insulin-stimulated muscle carnitine uptake in healthy young men
Shannon, C. E., Nixon, A., Greenhaff, P. L., & Stephens, F. B. (2015) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.119826 · Cited by 20
“Mean blood velocity was determined at the same anatomic location by integration of the pulsed-wave Doppler signal (22).”
MethodDirks, M. L., Wall, B. T., Otten, B., Cruz, A. M., Dunlop, M. V., BARKER, A. R., & Stephens, F. B. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz049 · Cited by 21
“was determined at the same anatomic location by integration of the pulsed-wave Doppler signal for a minimum of 8 cardiac cycles (33).”
MethodA Wind Tunnel Setup for Fluid-Structure Interaction Measurements Using Optical Methods
Nietiedt, S., Wester, T. T. B., Langidis, A., Kröger, L., Rofallski, R., Göring, M., Kühn, M., Gülker, G., & Lühmann, T. (2022) · Sensors · doi:10.3390/s22135014 · Cited by 19
Color Doppler sonographic determination of renal blood flow in healthy children.
Scholbach, T. (1999) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1999.18.8.559 · Cited by 18
Flow Estimation Using Ultrasound Imaging (Color M-Mode) and Computer Postprocessing
Juul, R., Slørdahl, S. A., Torp, H. G., Angelsen, B., & Brubakk, A. O. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.149 · Cited by 18
“…output measurement (Magnin et aI., 1981), and volume flow measure ment in the aorta (Eik-Nes et aI., 1980, 1984; Walter et aI., 1986) have shown varying inter- and intravar iability compared to gold standard flow, with a wide range of root mean square errors, from 9 to 10 1 % (Hoskins, 1990).”
BackgroundThe Impact of Disuse and High-Fat Overfeeding on Forearm Muscle Amino Acid Metabolism in Humans
Wall, B. T., Cruz, A. M., Otten, B., Dunlop, M. V., Fulford, J., Porter, C. C., Abdelrahman, D. R., Stephens, F. B., & Dirks, M. L. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa184 · Cited by 17
Medical Imaging in Clinical Practice
Erondu, O. F. (2013) · InTech eBooks · doi:10.5772/45925 · Cited by 16
Cerebral Blood Flow Velocity in Normal, Full-Term Newborns Is Not Related to Ductal Closure
Batton, D. G. (1992) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1992.02160180097025 · Cited by 14
Saxton, H., Xu, X., Schenkel, T., & Halliday, I. (2024) · Journal of Computational Science · doi:10.1016/j.jocs.2024.102287 · Cited by 15
“Systemic arterial pressure and flow are obtained via arterial line measurements and Doppler ultrasound [54,55], leading to evaluation of pulse pressure in the systemic artery ( 𝑃𝑃 𝑠𝑎 ) and mean arterial flow ( ̄𝑄 𝑠𝑎 ) respectively.”
MethodNon-invasive real-time monitoring of cell concentration and viability using Doppler ultrasound.
Akbari, S., Anderson, P., Zang, H., Ganjian, A., Balke, R., Kwon, T., & Pollard, D. (2022) · SLAS technology · doi:10.1016/j.slast.2022.09.003 · Cited by 11
Radar-Based Radial Arterial Pulse Rate and Pulse Pressure Analysis
Rong, Y., Mishra, K. V., & Bliss, D. W. (2021) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco54536.2021.9616318 · Cited by 11
Velocity profiles in the human ductus venosus: a numerical fluid structure interaction study
Leinan, P. R., Degroote, J., Kiserud, T., Skallerud, B., Vierendeels, J., & Hellevik, L. R. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0460-1 · Cited by 11
“These challenges add to the normal difficulties faced in volumetric flow rate estimation with Doppler ultrasound, such as beam angle, mean flow calculation and vessel area estimation (Hoskins 1990).”
BackgroundPennati, G., Socci, L., Rigano, S., Boito, S., & Ferrazzi, E. M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.924642 · Cited by 12
“Doppler technique is relatively simple, in practice several potential sources of error exist [ 6 ], [7].”
BackgroundEstimation of the Doppler ultrasound maximal umbilical waveform envelope: I. Estimation method
Doherty, D. A., JAMES, I. R., & Newnham, J. P. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00575-6 · Cited by 11
Moonmanee, T., Navanukraw, C., Yama, P., & Jitjumnong, ๋. (2018) · Reproductive Biology · doi:10.1016/j.repbio.2018.01.008 · Cited by 10
Fei, D. Y. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00032-m · Cited by 10
Evaluation of an automated real-time spectral analysis technique
Rickey, D. W., & Fenster, A. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02033-0 · Cited by 10
Technologies for Hemodynamic Measurements: Past, Present and Future
Corazza, I., Zecchi, M., Corsini, A., Marcelli, E., & Cercenelli, L. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-816861-5.00022-8 · Cited by 13
Villar, R., & Hughson, R. L. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/3/291 · Cited by 9
“…1985, Nelson and Pretorius 1988, Hoskins 1990), (2) improper alignment of the ultrasound beam with the artery (Gill 1985, Nelson and Pretorius 1988, Hoskins 1990, Radegran 1997), (3) Doppler signal processing (Gill 1985, Nelson and Pretorius 1988, Hoskins 1990) and (4) physiological sources…”
BackgroundInfluentialColor-Flow Duplex Hemodynamic Assessment of Runoff in Ischemic Lower Limb Revascularization
Rossi, F. H., Puech‐Leão, P., Izukawa, N. M., Pontes, S. C., Kambara, A. M., Barreto, R., Saleh, M. H., Petisco, A. C. G. P., & Oliveira, L. A. V. (2006) · Vascular · doi:10.2310/6670.2006.00031 · Cited by 9
Apicella, M. C. A., Jameson, T. S. O., Monteyne, A. J., Pavis, G. F., Abdelrahman, D. R., Murton, A. J., Alamdari, N., Dirks, M. L., Wall, B. T., & Stephens, F. B. (2025) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00365.2024 · Cited by 8
Advanced Lab-on-Tip ultrasound detectors: A numerical analysis
Rossi, B., Cutolo, M. A., & Giaquinto, M. (2022) · Results in Optics · doi:10.1016/j.rio.2022.100312 · Cited by 7
Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer
Alexander, A. A., Palazzo, J., Ahmad, N. R., Liu, J., Forsberg, F., & Marks, J. H. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)02392-5 · Cited by 7
A computational tool for quantitative assessment of peripheral arteries in ultrasound images
Higa, M., Pilon, P. E., Lage, S. G., & Gutierrez, M. A. (2009) · Computers in Cardiology Conference · Cited by 6
Compressed Ultrasound Imaging: From Sub-Nyquist Rates to Super Resolution
Drori, O., Mamistvalov, A., Solomon, O., & Eldar, Y. C. (2021) · IEEE BITS the Information Theory Magazine · doi:10.1109/mbits.2021.3103144 · Cited by 6
“Finally, various versions of Doppler ultrasound use designated transmit schemes to improve spectral resolution and estimate flow velocities [22].”
BackgroundHuman Ductus Venosus Velocity Profiles in the First Trimester
Leinan, P. R., Kiserud, T., & Hellevik, L. R. (2013) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-013-0133-y · Cited by 6
Stefopoulou, M., Johnson, J., Wilsgaard, T., Lindgren, P., Herling, L., Kiserud, T., & Acharya, G. (2020) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13950 · Cited by 7
Apicella, M. C. A., Jameson, T. S. O., Monteyne, A. J., Pavis, G. F., Abdelrahman, D. R., Murton, A. J., Alamdari, N., Dirks, M. L., Wall, B. T., & Stephens, F. B. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf410 · Cited by 8
Janerot-Sjöberg, B., Eidenvall, L., Loyd, D., Wranne, B., & Ask, P. (1993) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1993.tb09499.x · Cited by 5
Physics: principles, practice and artefacts
McDicken, W. N., & Hoskins, P. R. (2006) · Elsevier eBooks · doi:10.1016/b978-0-443-10116-8.50005-1 · Cited by 5
Self-citationDirks, M. L., Jameson, T. S. O., Andrews, R. C., Dunlop, M. V., Abdelrahman, D. R., Murton, A. J., Wall, B. T., & Stephens, F. B. (2024) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00345.2023 · Cited by 4
Assessment of Uterine Blood Flow in Mild Primary Dysmenorrhea
Özbay, K., & Semiz, A. (2024) · Journal of Pain Research · doi:10.2147/jpr.s456239 · Cited by 4
“1,6,7 The intensity of pain due to PD can be evaluated using a visual analog scale (VAS), with “0” defining “no pain” and “10” representing the “worst imaginable pain”.”
Quantitative Assessment of Peripheral Arteries in Ultrasound Images
Antonio, M., Higa, M., Eduardo, P., Rebelo, M. S., & Lage, S. H. G. (2013) · InTech eBooks · doi:10.5772/53310 · Cited by 3
“This information can reveal important relationships between the frequency spectral pattern along the cardiac cycle and the presence of cardiovascular diseases [7-10].”
BackgroundBetry, C., Nixon, A., Greenhaff, P. L., & Simpson, E. J. (2020) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1275-4038 · Cited by 3
Doherty, D. A., JAMES, I. R., & Newnham, J. P. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00574-4 · Cited by 3
Sloth, E., Pedersen, E. M., Egeblad, H., Hasenkam, J. M., & Juhl, B. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00080-1 · Cited by 3
Kaddoura, T., Au, A. G., Kawchuk, G. N., Uwiera, R. R. E., Fox, R., & Zemp, R. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-27816-0 · Cited by 3
Physics and Instrumentation of Doppler Ultrasound
Hoskins, P. R., & McDicken, W. N. (1997) · Springer eBooks · doi:10.1007/978-3-642-60512-3_2 · Cited by 2
Self-citationSiemer, J., Binder, H., Willeke, C., Dorn, C. H. V., REINSBERG, J., Fimmers, R., van der Ven, H., & Schild, R. (2008) · Reproductive BioMedicine Online · doi:10.1016/s1472-6483(10)60202-7 · Cited by 2
Duplex Ultrasonography of the Mesenteric Circulation
Neschis, D. G., & Flinn, W. R. (2008) · Springer eBooks · doi:10.1007/978-1-84628-450-2_43 · Cited by 2
Greenberg, D., Emerson, K., Perez, S. O., Sylla, S., & Komorowski, J. R. (2023) · Journal of Exercise and Nutrition · doi:10.53520/jen2023.103141 · Cited by 1
Imaging Efficacy in Tumor Models
Kaimal, V., Leopold, W. R., & McConville, P. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-968-0_9 · Cited by 1
Quantificação semiautomática da velocidade do sangue em imagens de ultrassonografia Doppler
Higa, M., Pilon, P. E., Lage, S. H. G., & Gutierrez, M. A. (2011) · Research on Biomedical Engineering · doi:10.4322/rbeb.2011.002 · Cited by 2
Duplex Ultrasonography of the Mesenteric Circulation
Neschis, D. G., & Flinn, W. R. (2017) · Springer eBooks · doi:10.1007/978-3-319-54760-2_51 · Cited by 1
Lacey, J., & Mythen, M. G. (2019) · Lessons from the ICU · doi:10.1007/978-3-319-69269-2_27 · Cited by 1
Methodologies to Quantify Skeletal Muscle Blood Flow/Perfusion
Jones, E. J., & Phillips, B. E. (2023) · Neuromethods · doi:10.1007/978-1-0716-3315-1_15 · Cited by 1
Métodos para quantificação da artéria carótida em imagens de ultrassom modo-B e Doppler.
Higa, M. (2009) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.3.2009.tde-11082010-163813 · Cited by 4
“…perturbe o padrão de fluxo do sangue de uma artéria normal, haverá uma maior dispersão das velocidades com o consequente espalhamento do espectro (HOSKINS, 1990; YAO et al., 2004); ou então, quantitativamente, quando uma estenose corresponde à redução de 50% ou mais do diâmetro arterial, o…”
BackgroundMitchell, J., & Kramschuster, K. (2009) · Physiotherapy Theory and Practice · doi:10.1080/09593980902776647 · Cited by 1
“Fax: þ 1 307 7665625; E-mail: jeanette_research@ hotmail.com 228 2004; Hallerstam and Rosfors, 2004; Hoskins, 1990; Licht, Christensen, Hojgaard, and HoilundCarlsen, 1998a; Licht, Christensse, Hojgaard, and Marving, 1998b; Licht, Christensen, and HoilundCarlsen, 1999; Nicolau et al, 2000, 2001;…”
BackgroundShinoura, N., Takahashi, M., & Yamada, R. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.11.1527 · Cited by 1
McDicken, W. N., & Hoskins, P. R. (2008) · Elsevier eBooks · doi:10.1016/b978-84-8086-328-5.50001-0
Self-citationRossi, F. H. (2006) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2006.tde-04122006-101149
Duplex Ultrasonography of the Mesenteric Circulation
Flinn, W. R., & Sandager, G. P. (2000) · Springer eBooks · doi:10.1007/978-1-4471-3837-2_29
Electromagnetic flow measurement using a magnetic resonance imaging static field
Burns, S. M., Barlow, T. W., Katzberg, R. W., & Brock, J. M. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80148-5
“In the same article, the authors [14] stated that with ultrasound transducers attached directly to the vessel, flow errors generally could be kept under 100/6.”
BackgroundQUANTIFICATION OF BLOOD FLOW VELOCITY USING COLOR SENSING
Sanghani, A. D. (2015) · DigitalCommons - CalPoly (California State Polytechnic University) · doi:10.15368/theses.2015.145
Metadata
- Authors
- Hoskins, P. R.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- Corresponding author
- Hoskins, P R
- ORCID
- Hoskins, P R
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1990-02
- Volume
- 11
- Issue
- 1
- Pages
- 1-26
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2080576241
- Semantic Scholar
- 88ba39f52a356f17f61a53a623ca311f68fa1261
- Cited by
- 109
- References
- 230
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 5 · 2022: 6 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 2 · 2016: 1 · 2015: 2 · 2013: 7 · 2012: 5
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Physics and Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Keywords
- arterial blood flow, Doppler ultrasound, volumetric flow measurement, waveform analysis, duplex ultrasound, colour flow imaging, carotid artery, lower limb arteries, renal artery, kidney transplantation, cerebral blood flow, tumour blood flow, attenuation compensation, measurement accuracy, Doppler shift
- MeSH terms
- Adult, Arteries, Blood Flow Velocity, Color, Female, Humans, Infant, Newborn, Ultrasonography, Ultrasonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.