Photoelectric plethysmography-some fundamental aspects of the reflection and transmission methods
The DOI matches its Crossref record.
Abstract
In photoelectric plethysmography a distinction is made between the reflection methods. Uncertainties still exist, especially regarding the origin of the reflected signal: some investigators attach quantitative value to the amplitude of the plethysmogram. The various findings are reconsidered. Various fluids are pulsatingly pumped through an in vitro circuit. Flow, pressure and volume pulsations are measured, as is the total light intensity detected by a photoelectric plethysmograph with the small variations caused in it by the pulsations in flow. Both phase and amplitude of the resulting plethysmogram are studied and the results compared with those found in vivo at the fingers and auricles. In vitro, the variations in light reflection are in phase with the volume pulsations: this can only be ascribed to reflection by orienting erythrocytes. In vivo, however, the light reflection, like the light transmission, is in anti-phase with the volume excursions, thus eliminating the determinative effect of light reflection by orienting erythrocytes--the strong reflection from surrounding tissues completely dominates reflection from erythrocytes. Since erythrocytes also have absorptive properties, and the light reflection is in anti-phase with the volume excursions, it is concluded that this absorptivity can manifest itself over the strong reflection from surrounding tissue. In vivo, therefore, the reflection plethysmogram is, in principle, an absorption measurement. The relationship between intensity of detected light and resultant voltage may not be linear: this nonlinearity may not be neglected when amplitude changes are compared. Amplitude changes of different plethysmograms may only be compared quantitatively if there is no difference in their light-voltage relationship.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“…processes in relation to PPG measurements (Hertzman and Randall 1948, Brown et al 1965, D’Agrosa and Hertzman 1967, Weinman 1967, Zweifler et al 1967, Challoner 1979, Ochoa and Ohara 1980, Nijboer et al 1981, Roberts 1982, Lindberg and Öberg 1993, de Trafford and Lafferty 1984, Kamal et al 1989).”
MethodUtility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Non-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Metadata
- Authors
- Nijboer, J. A., Dorlas, J. C., & Mahieu, H. F.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1981-08
- Volume
- 2
- Issue
- 3
- Pages
- 205-215
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2079609298
- Cited by
- 116
- References
- 0
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoelectric plethysmography-some fundamental aspects of the reflection and transmission methods. https://app.cochat.ai/papers/10.1088/0143-0815/2/3/004
- The paper
- Nijboer, J. A., Dorlas, J. C., & Mahieu, H. F. (1981). Photoelectric plethysmography-some fundamental aspects of the reflection and transmission methods. Clinical Physics and Physiological Measurement. https://doi.org/10.1088/0143-0815/2/3/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.