Contrast-enhanced microwave imaging of breast tumors: a computational study using 3D realistic numerical phantoms
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The detection of early-stage tumors in the breast by microwave imaging is challenged by both the moderate endogenous dielectric contrast between healthy and malignant glandular tissues and the spatial resolution available from illumination at microwave frequencies. The high endogenous dielectric contrast between adipose and fibroglandular tissue structures increases the difficulty of tumor detection due to the high dynamic range of the contrast function to be imaged and the low level of signal scattered from a tumor relative to the clutter scattered by normal tissue structures. Microwave inverse scattering techniques, used to estimate the complete spatial profile of the dielectric properties within the breast, have the potential to reconstruct both normal and cancerous tissue structures. However, the ill-posedness of the associated inverse problem often limits the frequency of microwave illumination to the UHF band within which early-stage cancers have sub-wavelength dimensions. In this computational study, we examine the reconstruction of small, compact tumors in three-dimensional numerical breast phantoms by a multiple-frequency inverse scattering solution. Computer models are also employed to investigate the use of exogenous contrast agents for enhancing tumor detection. Simulated array measurements are acquired before and after the introduction of the assumed contrast effects for two specific agents currently under consideration for breast imaging: microbubbles and carbon nanotubes. Differential images of the applied contrast demonstrate the potential of the approach for detecting the preferential uptake of contrast agents by malignant tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computational Electrodynamics: The Finite-Difference Time-Domain Method
Taflove, A. (1995) · Cited by 10,626
Computational electrodynamics, the finite-difference time-domain method
Rycroft, M. J. (1996) · Journal of Atmospheric and Terrestrial Physics · doi:10.1016/0021-9169(96)80449-1 · Cited by 9,418
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The Debye parameters assigned to the homogeneous skin region [29] are also given in table 1.”
BackgroundWaves and Fields in Inhomogenous Media
Chew, W. C. (1999) · doi:10.1109/9780470547052 · Cited by 3,986 · cited 9×
“Parallelization of the forward simulations, implementation of the inverse solution on the GPU, and advances in GPU performance are expected to reduce the time per DBIM iteration by about a factor of 10 [38].”
MethodInfluentialMaeda, H. (2001) · Advances in Enzyme Regulation · doi:10.1016/s0065-2571(00)00013-3 · Cited by 2,495
In vivo biodistribution and highly efficient tumour targeting of carbon nanotubes in mice
Liu, Z., Cai, W., He, L., Nakayama, N., Chen, K., Sun, X., Chen, X., & Dai, H. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.170 · Cited by 1,436 · cited 1×
“The preferential uptake of a contrast agent by malignant tissue [19, 20] could enhance the contrast of the malignant tissue relative to the healthy surrounding tissue and allow microwave detection via comparative imaging using pre- and post-contrast measurements.”
BackgroundLazebnik, M., Popovic, D., McCartney, L., Watkins, C. B., Lindstrom, M. J., Harter, J. M., Sewall, S., Ogilvie, T., Magliocco, A. M., Breslin, T. M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/20/002 · Cited by 1,402 · cited 2×
“Since each phantom in the repository only comprises normal tissues, we add a homogeneous spherical inclusion having the median properties of malignant glandular breast tissue, as characterized by Lazebnik et al [15] and given in table 1.”
MethodSelf-citationElectromagnetic Wave Propagation, Radiation, and Scattering: From Fundamentals to Applications
Ishimaru, A. (2017) · Wiley eBooks · doi:10.1002/9781119079699 · Cited by 1,339
In vivo Biodistribution and Highly Efficient Tumour Targeting of Carbon Nanotubes in Mice
Liu, Z., Cai, W., He, L., Nakayama, N., Chen, K., Sun, X., Chen, X., & Dai, H. (2020) · Nano-Enabled Medical Applications · doi:10.1201/9780429399039-14 · Cited by 1,213
Lazebnik, M., McCartney, L., Popovic, D., Watkins, C. B., Lindstrom, M. J., Harter, J. M., Sewall, S., Magliocco, A. M., Booske, J. H., Okoniewski, M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/001 · Cited by 770 · cited 1×
“We use a least-squares fit of the single-pole Debye relaxation model to the reported properties of ex-vivo breast tissues [28] over our frequency range of interest, 0.”
MethodSelf-citationLi, X., Bond, E., Veen, B. D. V., & Hagness, S. C. (2005) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2005.1436217 · Cited by 438
Self-citationZastrow, E., Davis, S. K., Lazebnik, M., Kelcz, F., Veen, B. D. V., & Hagness, S. C. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002130 · Cited by 353 · cited 2×
“Test beds and data generation Measurements for our study are simulated using anatomically realistic numerical models from the University of Wisconsin Computational Electromagnetics Laboratory’s (UWCEM) breast phantom repository [25, 26].”
MethodSelf-citationInitial Clinical Experience with Microwave Breast Imaging in Women with Normal Mammography
Meaney, P. M., Fanning, M. W., Raynolds, T., Fox, C. J., Fang, Q., Kogel, C. A., Poplack, S. P., & Paulsen, K. D. (2007) · Academic Radiology · doi:10.1016/j.acra.2006.10.016 · Cited by 335 · cited 1×
“Inverse scattering approaches have been applied to data from numerical and experimental models of the breast, and some preliminary clinical studies have been performed [12, 13].”
MethodElectromagnetic Breast Imaging: Results of a Pilot Study in Women with Abnormal Mammograms
Poplack, S. P., Tosteson, T. D., Wells, W. A., Pogue, B. W., Meaney, P. M., Hartov, A., Kogel, C. A., Soho, S. K., Gibson, J. J., & Paulsen, K. D. (2007) · Radiology · doi:10.1148/radiol.2432060286 · Cited by 299 · cited 1×
“0266-5611/10/074009+22$30.00 © 2010 IOP Publishing Ltd Printed in the UK & the USA 1”
InfluentialShea, J. D., Kosmas, P., Hagness, S. C., & Veen, B. D. V. (2010) · Medical Physics · doi:10.1118/1.3443569 · Cited by 284 · cited 1×
“0266-5611/10/074009+22$30.00 © 2010 IOP Publishing Ltd Printed in the UK & the USA 1”
InfluentialSelf-citationKuhl, C. K. (2000) · European Radiology · doi:10.1007/s003300050006 · Cited by 221 · cited 1×
“For example, breast malignancies are imaged in MRI with the introduction of a gadolinium contrast agent [18].”
BackgroundMashal, A., Sitharaman, B., Li, X., Avti, P., Sahakian, A. V., Booske, J. H., & Hagness, S. C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042597 · Cited by 160 · cited 2×
“In the case of carbon nanotube contrast agents, we fit Debye models to the reported dielectric properties measurements for an experimental material mimicking the dielectric properties of malignant tissue with and without a 2 mg mL−1 concentration of carbon nanotubes [23].”
BackgroundMethodSelf-citationWinters, D. W., Shea, J. D., Kosmas, P., Veen, B. D. V., & Hagness, S. C. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2008959 · Cited by 155 · cited 2×
“The three-dimensional (3D) imaging results presented in [9, 11] were obtained with a frequency-domain inverse scattering algorithm formulated using the distorted Born iterative method (DBIM) [14].”
BackgroundMethodSelf-citationComputational modeling of three-dimensional microwave tomography of breast cancer
Bulyshev, A., Semenov, S. Y., Souvorov, A. E., Svenson, R. H., Nazarov, A. G., Sizov, Y. E., & Tatsis, G. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.942596 · Cited by 127
Microwave Biomedical Data Inversion Using the Finite-Difference Contrast Source Inversion Method
Gilmore, C., Abubakar, A., Hu, W., Habashy, T. M., & van den Berg, P. M. (2009) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2009.2016728 · Cited by 125 · cited 1×
“This level of noise is comparable to the noise levels specified in prior experimental and numerical microwave breast imaging studies [8, 10, 33].”
ResultMashal, A., Booske, J. H., & Hagness, S. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/3/011 · Cited by 121 · cited 1×
“We assume an effective change in dielectric contrast as suggested by preliminary studies of two potential contrast agents for use in microwave breast imaging: microbubbles [21] and carbon nanotubes [22, 23].”
BackgroundSelf-citationExperimental verification of super resolution in nonlinear inverse scattering
Chen, F., & Chew, W. C. (1998) · Applied Physics Letters · doi:10.1063/1.121547 · Cited by 107
Fang, Q., Meaney, P. M., & Paulsen, K. D. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832014 · Cited by 106 · cited 1×
“When the actual dielectric profile is frequency-dependent, the system can be transformed by a parametric model of the frequency dependence [6].”
BackgroundNonlinear Optimization: A Parallel Linear Algebra Standpoint
Apuzzo, M. D., Marino, M., Migdalas, A., Pardalos, P. M., & Toraldo, G. (2005) · Statistics, a series of textbooks and monographs · doi:10.1201/9781420028683.ch8 · Cited by 99
Gauging the impact of breast carcinoma screening in terms of tumor size and death rate
Michaelson, J. S., Satija, S., Kopans, D. B., Moore, R. H., Silverstein, M. J., Comegno, A., Hughes, K. S., Taghian, A. G., Powell, S. N., & Smith, B. (2003) · Cancer · doi:10.1002/cncr.11766 · Cited by 83 · cited 1×
“A survey of the size of the tumors detected in a large collection of breast cancer studies of various modalities shows that the median diameter of detected tumors ranges between 10 and 20 mm [30].”
BackgroundSingular Value Analysis of the Jacobian Matrix in Microwave Image Reconstruction
Fang, Q., Meaney, P. M., & Paulsen, K. D. (2006) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2006.879192 · Cited by 75 · cited 1×
“The resulting MF × K system is less ill-posed than a single-frequency system [34] and can be approximately inverted to yield a simultaneous solution for a frequency-independent contrast function v.”
Background
Cited by
On the Opportunities and Challenges in Microwave Medical Sensing and Imaging
Chandra, R., Zhou, H., Balasingham, I., & Narayanan, R. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2432137 · Cited by 418
Review of Microwaves Techniques for Breast Cancer Detection
Aldhaeebi, M. A., Alzoubi, K., Almoneef, T. S., Bamatraf, S. M., Attia, H., & Ramahi, O. M. (2020) · Sensors · doi:10.3390/s20082390 · Cited by 237
“[202] 3 GHz 40 3D-FDTD 10 mm and 20 mm GNIA”
Review of Electromagnetic Techniques for Breast Cancer Detection
Hassan, A. M., & El-Shenawee, M. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2169780 · Cited by 214
Metadata
- Authors
- Shea, J. D., Kosmas, P., Van Veen, B. D., & Hagness, S. C.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2010-06-11
- Volume
- 26
- Issue
- 7
- Pages
- 074009
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2135991127
- Cited by
- 158
- References
- 26
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.