Angular resolved time delay in photoemission
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We investigate theoretically the relative time delay of photoelectrons originating from different atomic subshells of noble gases. This quantity was measured via attosecond streaking and studied theoretically by Schultze et al (2010 Science 328 1658 ) for neon. A substantial discrepancy was found between the measured and the calculated values of the relative time delay. Several theoretical studies were put forward to resolve this issue, e.g., by including correlation effects. In the present paper we explore a further aspect, namely the directional dependence of time delay. In contrast to neon, for argon target a strong angular dependence of the time delay is found near the Cooper minimum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-resolved atomic inner-shell spectroscopy
Drescher, M., Hentschel, M., Kienberger, R., Uiberacker, M., Yakovlev, V., Scrinzi, A., Westerwalbesloh, T., Kleineberg, U., Heinzmann, U., & Krausz, F. (2002) · Nature · doi:10.1038/nature01143 · Cited by 1,470
Schultze, M., Fieß, M., Karpowicz, N., Gagnon, J., Korbman, M., Hofstetter, M., Neppl, S., Cavalieri, A. L., Komninos, Y., Mercouris, T., et al. (2010) · Science · doi:10.1126/science.1189401 · Cited by 1,121
Guénot, D., Klünder, K., Arnold, C. L., Kroon, D., Dahlström, J. M., Miranda, M., Fordell, T., Gisselbrecht, M., Johnsson, P., Mauritsson, J., et al. (2012) · Physical Review A · doi:10.1103/physreva.85.053424 · Cited by 139
Cited by
Advances in attosecond science
Calegari, F., Sansone, G., Stagira, S., Vozzi, C., & Nisoli, M. (2016) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/49/6/062001 · Cited by 491
Attosecond chronoscopy of photoemission
Pazourek, R., Nagele, S., & Burgdörfer, J. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.765 · Cited by 442
Angular dependence of photoemission time delay in helium
Heuser, S., Jiménez Galán, Á., Cirelli, C., Marante, C., Sabbar, M., Boge, R., Lucchini, M., Gallmann, L., Ivanov, I., Kheifets, A. S., et al. (2016) · Physical Review A · doi:10.1103/physreva.94.063409 · Cited by 161
Magrakvelidze, M., Madjet, M. E.-A., Dixit, G., Ivanov, M., & Chakraborty, H. S. (2015) · Physical Review A · doi:10.1103/physreva.91.063415 · Cited by 28
Metadata
- Authors
- Wätzel, J., Moskalenko, A. S., Pavlyukh, Y., & Berakdar, J.
- Venue
- Journal of Physics B: Atomic, Molecular and Optical Physics
- Publisher
- IOP Publishing
- Published
- 2014-12-31
- Volume
- 48
- Issue
- 2
- Pages
- 025602
- ISSN
- 0953-4075 (ISSN-L)
- 1361-6455
- OpenAlex
- W2074793427
- Cited by
- 43
- References
- 3
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Angular resolved time delay in photoemission. https://app.cochat.ai/papers/10.1088/0953-4075/48/2/025602
- The paper
- Wätzel, J., Moskalenko, A. S., Pavlyukh, Y., & Berakdar, J. (2015). Angular resolved time delay in photoemission. Journal of Physics B: Atomic, Molecular and Optical Physics. https://doi.org/10.1088/0953-4075/48/2/025602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.