Atom based RF electric field sensing
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Atom-based measurements of length, time, gravity, inertial forces and electromagnetic fields are receiving increasing attention. Atoms possess properties that suggest clear advantages as self calibrating platforms for measurements of these quantities. In this review, we describe work on a new method for measuring radio frequency (RF) electric fields based on quantum interference using either Cs or Rb atoms contained in a dielectric vapor cell. Using a bright resonance prepared within an electromagnetically induced transparency window it is possible to achieve high sensitivities, <1 μ V cm −1 Hz −1/2 , and detect small RF electric fields μ V cm −1 with a modest setup. Some of the limitations of the sensitivity are addressed in the review. The method can be used to image RF electric fields and can be adapted to measure the vector electric field amplitude. Extensions of Rydberg atom-based electrometry for frequencies up to the terahertz regime are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Cutting-edge terahertz technology
Tonouchi, M. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.3 · Cited by 6,301
Electromagnetically induced transparency: Optics in coherent media
Fleischhauer, M., Imamoglu, A., & Marangos, J. P. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.633 · Cited by 5,189 · cited 3×
“Theoretically the change in index of refraction is expected, but it is nevertheless reassuring to see the experimental result [10].”
BackgroundMethodResultInfluentialGallagher, T. F. (1994) · Cambridge University Press eBooks · doi:10.1017/cbo9780511524530 · Cited by 1,457
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Hartmann, M. (1984) · Acta Polymerica · doi:10.1002/actp.1984.010350426 · Cited by 1,071
Microwave electrometry with Rydberg atoms in a vapour cell using bright atomic resonances
Sedlacek, J. A., Schwettmann, A., Kübler, H., Löw, R., Pfau, T., & Shaffer, J. P. (2012) · Nature Physics · doi:10.1038/nphys2423 · Cited by 863
Self-citationChild, M. S., & Pechukas, P. (1976) · Physics Today · doi:10.1063/1.3023376 · Cited by 858
Mohapatra, A. K., Jackson, T. R., & Adams, C. S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.113003 · Cited by 665
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Atomic superheterodyne receiver based on microwave-dressed Rydberg spectroscopy
Jing, M., Hu, Y., Ma, J., Zhang, H., Zhang, L., Xiao, L., & Jia, S. (2020) · Nature Physics · doi:10.1038/s41567-020-0918-5 · Cited by 576
Digital communication with Rydberg atoms and amplitude-modulated microwave fields
Meyer, D. H., Cox, K. C., Fatemi, F. K., & Kunz, P. D. (2018) · Applied Physics Letters · doi:10.1063/1.5028357 · Cited by 255
A Molecular Approach to Quantum Sensing
Yu, C.-J., von Kugelgen, S., Laorenza, D. W., & Freedman, D. E. (2021) · ACS Central Science · doi:10.1021/acscentsci.0c00737 · Cited by 213
Atom-Based Sensing of Weak Radio Frequency Electric Fields Using Homodyne Readout
Kumar, S., Fan, H., Kübler, H., Sheng, J., & Shaffer, J. P. (2017) · Scientific Reports · doi:10.1038/srep42981 · Cited by 197
Self-citationEnhanced metrology at the critical point of a many-body Rydberg atomic system
Ding, D.-S., Liu, Z.-K., Shi, B.-S., Guo, G.-C., Mølmer, K., & Adams, C. S. (2022) · Nature Physics · doi:10.1038/s41567-022-01777-8 · Cited by 183
Rydberg-atom-based digital communication using a continuously tunable radio-frequency carrier
Song, Z., Liu, H., Liu, X., Zhang, W., Zou, H., Zhang, J., & Qu, J. (2019) · Optics Express · doi:10.1364/oe.27.008848 · Cited by 166
Kumar, S., Fan, H., Kübler, H., Jahangiri, A. J., & Shaffer, J. P. (2017) · Optics Express · doi:10.1364/oe.25.008625 · Cited by 163
“photon shot noise limit in cases where sub-100 nV cm−1Hz−1/2 sensitivities need to be achieved is nontrivial for Rydberg atom-based RF E-field sensing because increasing the probe laser power leads to power broadening as well as the possible reduction of T2 depending on how the other parameters of the sensor are const…”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Fan, H., Kumar, S., Sedlacek, J., Kübler, H., Karimkashi, S., & Shaffer, J. P.
- Venue
- Journal of Physics B: Atomic, Molecular and Optical Physics
- Publisher
- IOP Publishing
- Published
- 2015-09-09
- Volume
- 48
- Issue
- 20
- Pages
- 202001
- ISSN
- 0953-4075 (ISSN-L)
- 1361-6455
- OpenAlex
- W1883624694
- Cited by
- 367
- References
- 47
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.