The effect of field parameters, nanoparticle properties and immobilization on the specific heating power in magnetic particle hyperthermia
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Magnetic nanoparticles (MNP) are intended for utilization in cancer therapy as they produce damaging heat in the presence of AC magnetic fields. In order to reach the required temperature with minimum particle concentration in tissue the specific heating power (SHP) of MNP should be as high as possible. The aim was to clarify the influence of magnetic field parameters and nanoparticle properties on the SHP. As usual ferrofluids exhibit broad size distributions, a magnetic fractionation of a commercial iron oxide nanoparticle suspension was performed in order to obtain particles with varying properties. The fractions obtained were characterized by means of atomic force microscopy and magnetometry, among other techniques. Frequency spectra of the susceptibility show clear peaks at low frequencies related to the Brown relaxation. This effect vanishes after particle immobilization. Theoretical spectra considering experimentally determined size distributions are in agreement with experimental data. The SHP derived from AC susceptometry is in accordance with that directly determined by calorimetry. A maximum SHP of 160 W g−1 (400 kHz, 8 kA m−1) was detected for the largest particles, showing a behaviour in the transitional regime between superparamagnetic and stable ferromagnetic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrodynamics of Continuous Media
Landau, L. D., Lifshitz, E. M., & King, A. L. (1961) · American Journal of Physics · doi:10.1119/1.1937882 · Cited by 10,997
A mechanism of magnetic hysteresis in heterogeneous alloys
Stoner, E. C., & Wohlfarth, E. P. (1948) · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences · doi:10.1098/rsta.1948.0007 · Cited by 5,405
Electrodynamics of Continuous Media
Kemmer, N. (1961) · Physics Bulletin · doi:10.1088/0031-9112/12/6/014 · Cited by 4,884
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Introduction to the Theory of Ferromagnetism
Aharoni, A. (2001) · doi:10.1093/oso/9780198508083.001.0001 · Cited by 1,112
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Introduction to the Theory of Ferromagnetism
Aharoni, A., & Arrott, A. (1997) · Physics Today · doi:10.1063/1.881916 · Cited by 952
Measurements of particle size distribution parameters in ferrofluids
Chantrell, R., Popplewell, J., & Charles, S. (1978) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1978.1059918 · Cited by 718
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Physical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658
Self-citationAn eigenfunction expansion method for the analysis of exponential decay curves
Provencher, S. W. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432601 · Cited by 617
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Theoretical single-domain grain size range in magnetite and titanomagnetite
Butler, R. F., & Banerjee, S. K. (1975) · Journal of Geophysical Research · doi:10.1029/jb080i029p04049 · Cited by 552
Maghemite nanoparticles with very high AC-losses for application in RF-magnetic hyperthermia
Hergt, R., Hiergeist, R., Hilger, I., Kaiser, W. A., Lapatnikov, Y., Margel, S., & Richter, U. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2003.09.001 · Cited by 416
Self-citationIron Metabolism in the Reticuloendothelial System
Knutson, M., & Wessling-Resnick, M. (2003) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.1080/713609210 · Cited by 355
Enhancement of AC-losses of magnetic nanoparticles for heating applications
Hergt, R., Hiergeist, R., Zeisberger, M., Glöckl, G., Weitschies, W., Ramirez, L. P., Hilger, I., & Kaiser, W. A. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2004.03.034 · Cited by 187
Self-citationMagnetic Properties of Hydrothermally Recrystallized Magnetite Crystals
Heider, F., Dunlop, D. J., & Sugiura, N. (1987) · Science · doi:10.1126/science.236.4806.1287 · Cited by 182
Three-dimensional micromagnetic calculations for magnetite using FFT
Fabian, K., Kirchner, A., Williams, W., Heider, F., Leibl, T., & Huber, A. (1996) · Geophysical Journal International · doi:10.1111/j.1365-246x.1996.tb06354.x · Cited by 157
Hysteresis losses of magnetic nanoparticle powders in the single domain size range
Dutz, S., Hergt, R., Mürbe, J., Müller, R., Zeisberger, M., Andrä, W., Töpfer, J., & Bellemann, M. E. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.06.005 · Cited by 150
Self-citationMagnetic separation techniques: their application to medicine
Kemsheadl, J. T., & UGELSTAD, J. (1985) · Molecular and Cellular Biochemistry · doi:10.1007/bf00220980 · Cited by 88
Magnetic fractionation of magnetic fluids
Rheinländer, T., Kötitz, R., Weitschies, W., & Semmler, W. (2000) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)00439-x · Cited by 64
Self-citationNanoparticle Composition of a Ferrofluid and Its Effects on the Magnetic Properties
Büscher, K., Helm, C. A., Gross, C., Glöckl, G., Romanus, E., & Weitschies, W. (2004) · Langmuir · doi:10.1021/la030261x · Cited by 59
Self-citation
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic particle hyperthermia: nanoparticle magnetism and materials development for cancer therapy
Hergt, R., Dutz, S., Müller, R., & Zeisberger, M. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/38/s26 · Cited by 977
Self-citationGuardia, P., Di Corato, R., Lartigue, L., Wilhelm, C., Espinosa, A., Garcia-Hernandez, M., Gazeau, F., Manna, L., & Pellegrino, T. (2012) · ACS Nano · doi:10.1021/nn2048137 · Cited by 752
Magnetic particle hyperthermia—a promising tumour therapy?
Dutz, S., & Hergt, R. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/45/452001 · Cited by 525
Self-citation
Metadata
- Authors
- Glöckl, G., Hergt, R., Zeisberger, M., Dutz, S., Nagel, S., & Weitschies, W.
- Venue
- Journal of Physics: Condensed Matter
- Publisher
- IOP Publishing
- Published
- 2006-09-08
- Volume
- 18
- Issue
- 38
- Pages
- S2935-S2949
- ISSN
- 0953-8984 (ISSN-L)
- 1361-648X
- OpenAlex
- W2078298455
- Cited by
- 158
- References
- 22
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.