Cited by 66Advanced Measurement and Metrology TechniquesOptical measurement and interference techniquesAdvanced Fiber Laser Technologies

Length and refractive index measurement by Fourier transform interferometry and frequency comb spectroscopy

Balling, Petr, Mašika, Pavel, Křen, Petr, Doležal, Miroslav·2012·Measurement Science and Technology

Abstract

In this paper we describe the progress we have made in our simultaneous length measurement and the femtosecond comb interferometric spectroscopy in a conventional arrangement with a moving mirror. Scanning and detection over an interval longer than the distance between two consecutive pulses of the frequency comb allow for a spectral resolution of the individual frequency modes of the comb. Precise knowledge of comb mode frequency leads to a precise estimation of the spectral characteristics of inspected phenomena. Using the pulse train of the frequency comb allows for measurement with highly unbalanced lengths of interferometer arms, i.e. an absolute long distance measurement. Further, we present a non-contact (double sided) method of measurement of the length/thickness of plane-parallel objects (gauge blocks, glass samples) by combining the fs comb (white light) with single frequency laser interferometry. The position of a fringe packet is evaluated by estimating the stationary phase position for any wavelength in the spectral band used. The repeatability of this position estimation is a few nanometres regardless of whether dispersion of the arms is compensated (transform limited fringe packet ?10 fringes FWHM) or highly different (fringe packet stretched to >200 fringes FWHM). The measurement of steel gauge block by this method was compared with the standard method, and deviation (+13 ? 12) nm for gauge blocks (2 to 100) mm was found. The measurement of low reflecting ceramic gauges or clear glass samples was also tested. In the case of glass, it becomes possible to measure simultaneously both the thickness and the refractive index (and dispersion) of flat samples.

Integrity signals

Registry

Crossref · 10.1088/0957-0233/23/9/094001

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Balling, P., Mašika, P., Křen, P., & Doležal, M.
Venue
Measurement Science and Technology
Published
2012-07-25
Volume
23
Issue
9
Pages
094001
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2048609351
Cited by
66
References
41
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 4 · 2021: 9 · 2020: 2 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 9 · 2015: 13 · 2014: 4 · 2013: 6 · 2012: 1
FWCI
11.74
Type
journal article
Language
en
Open access
closed
Locations
Measurement Science and Technology (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
Keywords
length measurement, refractive index measurement, femtosecond optical frequency comb, Fourier transform interferometry, gauge blocks, glass thickness measurement, dispersion measurement, non-contact measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review