Kinetic and thermal energy harvesters for implantable medical devices and biomedical autonomous sensors
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Implantable medical devices usually require a battery to operate and this can represent a severe restriction. In most cases, the implantable medical devices must be surgically replaced because of the dead batteries; therefore, the longevity of the whole implantable medical device is determined by the battery lifespan. For this reason, researchers have been studying energy harvesting techniques from the human body in order to obtain batteryless implantable medical devices. The human body is a rich source of energy and this energy can be harvested from body heat, breathing, arm motion, leg motion or the motion of other body parts produced during walking or any other activity. In particular, the main human-body energy sources are kinetic energy and thermal energy. This paper reviews the state-of-art in kinetic and thermoelectric energy harvesters for powering implantable medical devices. Kinetic energy harvesters are based on electromagnetic, electrostatic and piezoelectric conversion. The different energy harvesters are analyzed highlighting their sizes, energy or power they produce and their relative applications. As they must be implanted, energy harvesting devices must be limited in size, typically about 1 cm 3 . The available energy depends on human-body positions; therefore, some positions are more advantageous than others. For example, favorable positions for piezoelectric harvesters are hip, knee and ankle where forces are significant. The energy harvesters here reported produce a power between 6 nW and 7.2 mW; these values are comparable with the supply requirements of the most common implantable medical devices; this demonstrates that energy harvesting techniques is a valid solution to design batteryless implantable medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thin-film thermoelectric devices with high room-temperature figures of merit
Venkatasubramanian, R., Siivola, E., Colpitts, T., & O'Quinn, B. (2001) · Nature · doi:10.1038/35098012 · Cited by 5,205
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008 · cited 1×
“In particular, a generic kinetic harvester is composed of a resonance mechanism [14, 15] that generates the swing of a proof mass and is designed according to the input vibration frequency in order to operate in resonance condition.”
Energy Harvesting Technologies
(2009) · Springer eBooks · doi:10.1007/978-0-387-76464-1 · Cited by 1,910
Erturk, A., & Inman, D. J. (2009) · Smart Materials and Structures · doi:10.1088/0964-1726/18/2/025009 · Cited by 1,417
A Distributed Parameter Electromechanical Model for Cantilevered Piezoelectric Energy Harvesters
Erturk, A., & Inman, D. J. (2008) · Journal of Vibration and Acoustics · doi:10.1115/1.2890402 · Cited by 1,249 · cited 1×
“The coupled distributed parameter solution of a piezoelectric energy harvester under base excitation was given for unimorph [39] and bimorph [40] cantilevers (i.”
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876 · cited 2×
“Energy consumed by the human body for different daily activities [11].”
Architectures for Vibration-Driven Micropower Generators
Mitcheson, P. D., Green, T. C., Yeatman, E. M., & Holmes, A. S. (2004) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2004.830151 · Cited by 753
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · cited 1×
“Other examples of implantable medical devices, such as blood pressure, implanted microelectrodes to monitor cerebral or intramuscular electromyographic (EMG) signals, are described in [4–7].”
Self-powered signal processing using vibration-based power generation
Amirtharajah, R., & Chandrakasan, A. P. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.668982 · Cited by 621 · cited 1×
“This is a significant value in comparison with other MEMS electrostatic generators [36], but the power obtained remains significantly below theoretically achievable values [37].”
Security and Privacy for Implantable Medical Devices
Halperin, D., Heydt-Benjamin, T. S., Fu, K., Kohno, T., & Maisel, W. H. (2008) · IEEE Pervasive Computing · doi:10.1109/mprv.2008.16 · Cited by 470 · cited 1×
“monitoring [1].”
Cited by
BaTiO3-Based Piezoelectrics: Fundamentals, Current Status, and Perspectives
Acosta, M., Novak, N., Rojas, V., Patel, S., Vaish, R., Koruza, J., Rossetti, G. A., & Rödel, J. (2017) · Applied Physics Reviews · doi:10.1063/1.4990046 · Cited by 1,451
Smart fabric sensors and e-textile technologies: a review
Castano, L. M., & Flatau, A. B. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/5/053001 · Cited by 793
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Locomotion of inchworm-inspired robot made of smart soft composite (SSC)
Wang, W., Lee, J.-Y., Rodrigue, H., Song, S.-H., Chu, W.-S., & Ahn, S.-H. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/4/046006 · Cited by 242
Sensing using plasmonic nanostructures and nanoparticles
Langer, J., Novikov, S. M., & Liz-Marzán, L. M. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/32/322001 · Cited by 232
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
“The power source is also a major contributor to the overall weight and size of the device, but with the advancements in MEMS (microelectromechanical systems) and nanotechnology, the electronic circuitry components have decreased dramatically [61,93,94].”
BackgroundSelf‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Multi-modal locomotion: from animal to application
Lock, R. J., Burgess, S. C., & Vaidyanathan, R. (2013) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/011001 · Cited by 185
Additive manufacturing of hydrogel-based materials for next-generation implantable medical devices
Chin, S. Y., Poh, Y. C., Kohler, A.-C., Compton, J. T., Hsu, L. L., Lau, K. M., Kim, S., Lee, B. W., Lee, F. Y., & Sia, S. K. (2017) · Science Robotics · doi:10.1126/scirobotics.aah6451 · Cited by 172
Metadata
- Authors
- Cadei, A., Dionisi, A., Sardini, E., & Serpelloni, M.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2013-11-13
- Volume
- 25
- Issue
- 1
- Pages
- 012003
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W1997321659
- Cited by
- 158
- References
- 45
- FWCI
- 35.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.