Kinetic and thermal energy harvesters for implantable medical devices and biomedical autonomous sensors
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Implantable medical devices usually require a battery to operate and this can represent a severe restriction. In most cases, the implantable medical devices must be surgically replaced because of the dead batteries; therefore, the longevity of the whole implantable medical device is determined by the battery lifespan. For this reason, researchers have been studying energy harvesting techniques from the human body in order to obtain batteryless implantable medical devices. The human body is a rich source of energy and this energy can be harvested from body heat, breathing, arm motion, leg motion or the motion of other body parts produced during walking or any other activity. In particular, the main human-body energy sources are kinetic energy and thermal energy. This paper reviews the state-of-art in kinetic and thermoelectric energy harvesters for powering implantable medical devices. Kinetic energy harvesters are based on electromagnetic, electrostatic and piezoelectric conversion. The different energy harvesters are analyzed highlighting their sizes, energy or power they produce and their relative applications. As they must be implanted, energy harvesting devices must be limited in size, typically about 1 cm 3 . The available energy depends on human-body positions; therefore, some positions are more advantageous than others. For example, favorable positions for piezoelectric harvesters are hip, knee and ankle where forces are significant. The energy harvesters here reported produce a power between 6 nW and 7.2 mW; these values are comparable with the supply requirements of the most common implantable medical devices; this demonstrates that energy harvesting techniques is a valid solution to design batteryless implantable medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thin-film thermoelectric devices with high room-temperature figures of merit
Venkatasubramanian, R., Siivola, E., Colpitts, T., & O'Quinn, B. (2001) · Nature · doi:10.1038/35098012 · Cited by 5,205
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008 · cited 1×
“In particular, a generic kinetic harvester is composed of a resonance mechanism [14, 15] that generates the swing of a proof mass and is designed according to the input vibration frequency in order to operate in resonance condition.”
Energy Harvesting Technologies
(2009) · Springer eBooks · doi:10.1007/978-0-387-76464-1 · Cited by 1,910
Erturk, A., & Inman, D. J. (2009) · Smart Materials and Structures · doi:10.1088/0964-1726/18/2/025009 · Cited by 1,417
A Distributed Parameter Electromechanical Model for Cantilevered Piezoelectric Energy Harvesters
Erturk, A., & Inman, D. J. (2008) · Journal of Vibration and Acoustics · doi:10.1115/1.2890402 · Cited by 1,249 · cited 1×
“The coupled distributed parameter solution of a piezoelectric energy harvester under base excitation was given for unimorph [39] and bimorph [40] cantilevers (i.”
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876 · cited 2×
“Energy consumed by the human body for different daily activities [11].”
Architectures for Vibration-Driven Micropower Generators
Mitcheson, P. D., Green, T. C., Yeatman, E. M., & Holmes, A. S. (2004) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2004.830151 · Cited by 753
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · cited 1×
“Other examples of implantable medical devices, such as blood pressure, implanted microelectrodes to monitor cerebral or intramuscular electromyographic (EMG) signals, are described in [4–7].”
Self-powered signal processing using vibration-based power generation
Amirtharajah, R., & Chandrakasan, A. P. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.668982 · Cited by 621 · cited 1×
“This is a significant value in comparison with other MEMS electrostatic generators [36], but the power obtained remains significantly below theoretically achievable values [37].”
Security and Privacy for Implantable Medical Devices
Halperin, D., Heydt-Benjamin, T. S., Fu, K., Kohno, T., & Maisel, W. H. (2008) · IEEE Pervasive Computing · doi:10.1109/mprv.2008.16 · Cited by 470 · cited 1×
“monitoring [1].”
Potential benefits of a non-linear stiffness in an energy harvesting device
Ramlan, R., Brennan, M. J., Mace, B. R., & Kovacic, I. (2010) · Nonlinear Dynamics · doi:10.1007/s11071-009-9561-5 · Cited by 432 · cited 1×
“Different approaches are reported in the literature: for examples, in [17], a material with nonlinear elastic characteristics or MEMS frequency upconverter operating at very low frequency (1–100 Hz) [18].”
A very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Review of graphene-based strain sensors
Zhao, J., Zhang, G.-Y., & Shi, D.-X. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/5/057701 · Cited by 387
Kulah, H., & Najafi, K. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917125 · Cited by 361 · cited 1×
“Different approaches are reported in the literature: for examples, in [17], a material with nonlinear elastic characteristics or MEMS frequency upconverter operating at very low frequency (1–100 Hz) [18].”
Electrostatic micro power generation from low-frequency vibration such as human motion
Naruse, Y., Matsubara, N., Mabuchi, K., Izumi, M., & Suzuki, S. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/9/094002 · Cited by 330 · cited 3×
“4 G) × 6 mm3 and 40 μW movements Naruse 2008/[38] Embedded into a Generic low Laboratory sinusoidal 20 × 45 Not available Test with a shaker biocompatible system frequency human input (6 Hz, 0.”
InfluentialOn Low-Frequency Electric Power Generation With PZT Ceramics
Platt, S. R., Farritor, S., & Haider, H. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.844704 · Cited by 294 · cited 2×
“Platt et al in [41, 42] use piezoelectric ceramics”
Ultra Low Power Bioelectronics: Fundamentals, Biomedical Applications, and Bio-Inspired Systems
Sarpeshkar, R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511841446 · Cited by 288
The Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants
Platt, S. R., Farritor, S., Garvin, K., & Haider, H. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.852482 · Cited by 232 · cited 3×
“Platt et al in [41, 42] use piezoelectric ceramics”
Mems inertial power generators for biomedical applications
Miao, P., Mitcheson, P. D., Holmes, A. S., Yeatman, E. M., Green, T. C., & Stark, B. H. (2006) · Microsystem Technologies · doi:10.1007/s00542-006-0152-9 · Cited by 204
Power sources and electrical recharging strategies for implantable medical devices
Wei, X., & Liu, J. (2008) · Frontiers of Energy and Power Engineering in China · doi:10.1007/s11708-008-0016-3 · Cited by 188
Micropower Circuits for Bidirectional Wireless Telemetry in Neural Recording Applications
Neihart, N. M., & Harrison, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856247 · Cited by 172 · cited 1×
“Keywords: energy harvesting, batteryless devices, micropower generator, implantable medical devices, self-powered systems, electromagnetic generators, electrostatic generators, piezoelectric generators, thermoelectric generator (Some figures may appear in colour only in the online journal)”
An Ultra-Low-Power Programmable Analog Bionic Ear Processor
Sarpeshkar, R., Salthouse, C., Sit, J.-J., Baker, M. W., Zhak, S. M., Lu, T. K.-T., Turicchia, L., & Balster, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844043 · Cited by 171 · cited 1×
“Cochlear 145 μW [21] 5.”
TASHIRO, R., Kabei, N., Katayama, K., Tsuboi, E., & TSUCHIYA, K. (2002) · Journal of Artificial Organs · doi:10.1007/s100470200045 · Cited by 170 · cited 3×
“Honeycomb structure for an electrostatic harvester, from [33].”
InfluentialSuitability of a thermoelectric power generator for implantable medical electronic devices
Yang, Y., Wei, X.-J., & Liu, J. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/18/042 · Cited by 163 · cited 7×
“3 K In vivo exposed in the 390 mm3 5 mV and In vivo test (rabbit) environment Not available Yang 2007/[19] Bi2Te3/Bi2Te2.”
InfluentialCardiac Pacemakers From the Patient’s Perspective
Wood, M. A., & Ellenbogen, K. A. (2002) · Circulation · doi:10.1161/01.cir.0000016183.07898.90 · Cited by 159
Power feasibility of implantable digital spike sorting circuits for neural prosthetic systems
Zumsteg, Z. S., Kemere, C., O'Driscoll, S., Santhanam, G., Ahmed, R. E., Shenoy, K. V., & Meng, T. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.854307 · Cited by 138
Energy harvesting for human wearable and implantable bio-sensors
Mitcheson, P. D. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627952 · Cited by 132
Evaluation of motions and actuation methods for biomechanical energy harvesting
Niu, P., Chapman, P., Riemer, R., & Zhang, X. (2005) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1355442 · Cited by 117 · cited 2×
“Table 2 [12] shows the amount of kinetic energy used, while table 3 [13] shows the thermal gradient for typical daily activities.”
Mini drug pump for ophthalmic use
Saati, S., Lo, R., Li, P.-Y., Meng, E., Varma, R., & Humayun, M. S. (2010) · Current Eye Research · doi:10.3109/02713680903521936 · Cited by 77
Reliability of B‐mode ultrasound for the measurement of body fat and muscle thickness
Ishida, Y., Carroll, J. F., Pollock, M. L., Graves, J. E., & Leggett, S. H. (1992) · American Journal of Human Biology · doi:10.1002/ajhb.1310040410 · Cited by 70 · cited 2×
“Human temperature gradients at ambient temperature of 25 ◦C [13].”
Body motion for powering biomedical devices
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333329 · Cited by 61 · cited 4×
“5 and 1 Hz Romero 2009/[16] NdFeB—copper Knee Laboratory normal 1.”
InfluentialWatkins, C., Shen, B., & Venkatasubramanian, R. (2005) · International Conference on Thermoelectrics (ICT) · doi:10.1109/ict.2005.1519934 · Cited by 60 · cited 1×
“Watkins et al [54, 55] describe a low-grade-heat energy harvester, consisting of an advanced thin superlattice thermoelectric film.”
Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E., & Roux, C. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2159512 · Cited by 59 · cited 1×
“4 cm3 Not available and Unpackaged 2011/[47, 48] standard (ISO 14243-1) (1 piezo) 7.”
Energy harvesting using vibrating structures excited by shock
Cavallier, B., Berthelot, P., Nouira, H., Foltête, E., Hirsinger, L., & Ballandras, S. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1603006 · Cited by 59 · cited 3×
“9 μW (1 piezo) Cavallier 2005/[51] PZT Generic human Laboratory shock by 87 mm3 Not available Non-resonant movements using a tin ball and 0.”
InfluentialBöttner, H. (2002) · International Conference on Thermoelectrics (ICT) · doi:10.1109/ict.2002.1190368 · Cited by 56 · cited 1×
“Micropelt thermoelectric microgenerator structure, from [57].”
A Linear Permanent Magnet Generator for Powering Implanted Electronic Devices
Nasiri, A., Zabalawi, S. A., & Jeutter, D. C. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2055891 · Cited by 48 · cited 7×
“In particular, the harvester proposed by Nasiri [30] exceeds the limit of 1 cm3 abundantly; nevertheless it is compatible with humanbody applications.”
InfluentialMicro-Machined Variable Capacitors for Power Generation
Mitcheson, P. D., Holmes, A. S., Yeatman, E. M., Green, T. C., & Miao, P. (2004) · Institute of physics conference series/Institute of Physics conference series · doi:10.1201/9781420034387.ch8 · Cited by 48 · cited 2×
“In [34, 35], Miao et al propose a MEMS electrostatic power generator.”
Packaging of Implantable Microsystems
Najafi, K. (2007) · 2007 IEEE Sensors · doi:10.1109/icsens.2007.4388335 · Cited by 38
An Arterial Cuff Energy Scavenger For Implanted Microsystems
Potkay, J. A., & Brooks, K. (2008) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2008.723 · Cited by 32 · cited 3×
“5 μW structure— (1,4 g, 6 Hz) requires vibration of the beam high forces Potkay 2008/[52] PVDF Artery Laboratory blood 0.”
InfluentialPower harvesting using PZT ceramics embedded in orthopedic implants
Chen, H., Liu, M., Chen, J., & Wang, Z. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1277 · Cited by 32 · cited 2×
“8 mW (3 piezos) (3 piezos) Chen 2010/[45] PZT ceramic Knee Laboratory International 0.”
IMES: An Implantable Myoelectric Sensor
Troyk, P. R., DeMichele, G. A., Kerns, D., & Weir, R. F. F. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352644 · Cited by 30
Lewandowski, B. E., Kilgore, K. L., & Gustafson, K. J. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9261-6 · Cited by 30
Self-powered instrumented knee implant for early detection of postoperative complications
Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, É., & Roux, C. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626199 · Cited by 28
A Self-Powered Telemetry System to Estimate the Postoperative Instability of a Knee Implant
Lahuec, C., Almouahed, S., Arzel, M., Gupta, D., Hamitouche, C., Jézéquel, M., Stindel, É., & Roux, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2069099 · Cited by 15 · cited 1×
“4 cm3 Not available and Unpackaged 2011/[47, 48] standard (ISO 14243-1) (1 piezo) 7.”
Low power circuits and systems for wireless neural stimulation
Arfin, S. K. (2011) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 15
Cited by
BaTiO3-Based Piezoelectrics: Fundamentals, Current Status, and Perspectives
Acosta, M., Novak, N., Rojas, V., Patel, S., Vaish, R., Koruza, J., Rossetti, G. A., & Rödel, J. (2017) · Applied Physics Reviews · doi:10.1063/1.4990046 · Cited by 1,451
Smart fabric sensors and e-textile technologies: a review
Castano, L. M., & Flatau, A. B. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/5/053001 · Cited by 793
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Locomotion of inchworm-inspired robot made of smart soft composite (SSC)
Wang, W., Lee, J.-Y., Rodrigue, H., Song, S.-H., Chu, W.-S., & Ahn, S.-H. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/4/046006 · Cited by 242
Metadata
- Authors
- Cadei, A., Dionisi, A., Sardini, E., & Serpelloni, M.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2013-11-13
- Volume
- 25
- Issue
- 1
- Pages
- 012003
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W1997321659
- Cited by
- 158
- References
- 45
- FWCI
- 35.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.