Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record.

In vitro characterization of movement, heating and visualization of magnetic nanoparticles for biomedical applications

Open access
Kalambur, Venkatasubramaniam S, Han, Bumsoo, Hammer, Bruce E, Shield, Thomas W, Bischof, John C·2005·Nanotechnology

Abstract

Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo , in the hyperthermic treatment of cancers, in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. In this study, a characterization of the movement and heating of three different types of magnetic nanoparticles in physiological systems in vitro is made in a known external magnetic field and alternating field respectively. Infra-red (IR) imaging and MR imaging were used to visualize these nanoparticles in vitro . A strong dependence on the size and the suspending medium is observed on the movement and heating of these nanoparticles. First, two of the particles (mean diameter d = 10 nm, uncoated Fe 3 O 4 and d = 2.8 µm, polystyrene coated Fe 3 O 4 +γ-Fe 2 O 3 ) did not move while only a dextran coated nanoparticle ( d = 50 nm, γ-Fe 2 O 3 ) moved in type 1 collagen used as an in vitro model system. It is also observed that the time taken by a collection of these nanoparticles to move even a smaller distance (5 mm) in collagen (∼100 min) is almost ten times higher when compared to the time taken to move twice the distance (10 mm) in glycerol (∼10 min) under the same external field. Second, the amount of temperature rise increases with the concentration of nanoparticles regardless of the microenvironments in the heating studies. However, the amount of heating in collagen (maximum change in temperature Δ T max ∼9 °C at 1.9 mg Fe ml −1 and 19 °C at 3.7 mg Fe ml −1 ) is significantly less than that in water (Δ T max ∼15 °C at 1.9 mg Fe ml −1 and 33 °C at 3.7 mg Fe ml −1 ) and glycerol (Δ T max ∼13.5 °C at 1.9 mg Fe ml −1 and 30 °C at 3.7 mg Fe ml −1 ). Further, IR imaging provides at least a ten times improvement in the range of imaging magnetic nanoparticles, whereby a concentration of (0–4 mg Fe ml −1 ) could bevisualized as compared to (0–0.4 mg Fe ml −1 ) by MR imaging. Based on these in vitro studies, important issues and parameters that require further understanding and characterization of these nanoparticles in vivo are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-4484/16/8/041

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Kalambur, V. S., Han, B., Hammer, B. E., Shield, T. W., & Bischof, J. C.
Venue
Nanotechnology
Published
2005-05-20
Volume
16
Issue
8
Pages
1221-1233
ISSN
  • 0957-4484 (ISSN-L)
  • 1361-6528
OpenAlex
W2090748925
Cited by
175
References
0
FWCI
6.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro characterization of movement, heating and visualization of magnetic nanoparticles for biomedical applications. https://app.cochat.ai/papers/10.1088/0957-4484/16/8/041
The paper
Kalambur, V. S., Han, B., Hammer, B. E., Shield, T. W., & Bischof, J. C. (2005). In vitro characterization of movement, heating and visualization of magnetic nanoparticles for biomedical applications. Nanotechnology. https://doi.org/10.1088/0957-4484/16/8/041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.