In vitro characterization of movement, heating and visualization of magnetic nanoparticles for biomedical applications
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo , in the hyperthermic treatment of cancers, in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. In this study, a characterization of the movement and heating of three different types of magnetic nanoparticles in physiological systems in vitro is made in a known external magnetic field and alternating field respectively. Infra-red (IR) imaging and MR imaging were used to visualize these nanoparticles in vitro . A strong dependence on the size and the suspending medium is observed on the movement and heating of these nanoparticles. First, two of the particles (mean diameter d = 10 nm, uncoated Fe 3 O 4 and d = 2.8 µm, polystyrene coated Fe 3 O 4 +γ-Fe 2 O 3 ) did not move while only a dextran coated nanoparticle ( d = 50 nm, γ-Fe 2 O 3 ) moved in type 1 collagen used as an in vitro model system. It is also observed that the time taken by a collection of these nanoparticles to move even a smaller distance (5 mm) in collagen (∼100 min) is almost ten times higher when compared to the time taken to move twice the distance (10 mm) in glycerol (∼10 min) under the same external field. Second, the amount of temperature rise increases with the concentration of nanoparticles regardless of the microenvironments in the heating studies. However, the amount of heating in collagen (maximum change in temperature Δ T max ∼9 °C at 1.9 mg Fe ml −1 and 19 °C at 3.7 mg Fe ml −1 ) is significantly less than that in water (Δ T max ∼15 °C at 1.9 mg Fe ml −1 and 33 °C at 3.7 mg Fe ml −1 ) and glycerol (Δ T max ∼13.5 °C at 1.9 mg Fe ml −1 and 30 °C at 3.7 mg Fe ml −1 ). Further, IR imaging provides at least a ten times improvement in the range of imaging magnetic nanoparticles, whereby a concentration of (0–4 mg Fe ml −1 ) could bevisualized as compared to (0–0.4 mg Fe ml −1 ) by MR imaging. Based on these in vitro studies, important issues and parameters that require further understanding and characterization of these nanoparticles in vivo are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Introduction to magnetic materials
(2009) · Materials Today · doi:10.1016/s1369-7021(09)70091-4 · Cited by 5,615
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
Hirsch, L. R., Stafford, R. J., Bankson, J. A., Sershen, S. R., Rivera, B., Price, R. E., Hazle, J. D., Halas, N. J., & West, J. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2232479100 · Cited by 3,955
Introduction to Magnetic Materials
Cullity, B. D., & Graham, C. D. (2008) · Wiley eBooks · doi:10.1002/9780470386323 · Cited by 3,164 · cited 1×
“Experimental methods are available to completely map out the field distribution around magnets [ 45 ].”
MethodNanoparticles in cancer therapy and diagnosis
Brigger, I., Dubernet, C., & Couvreur, P. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00044-3 · Cited by 3,039
In Vivo Imaging of Quantum Dots Encapsulated in Phospholipid Micelles
Dubertret, B., Skourides, P., Norris, D. J., Noireaux, V., Brivanlou, A. H., & Libchaber, A. (2002) · Science · doi:10.1126/science.1077194 · Cited by 3,019
Cahill, D. G., Ford, W. K., Goodson, K. E., Mahan, G. D., Majumdar, A., Maris, H. J., Merlin, R., & Phillpot, S. R. (2003) · Journal of Applied Physics · doi:10.1063/1.1524305 · Cited by 2,825
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Encyclopedia of Nanoscience and Nanotechnology
(2013) · Chemical & Engineering News Archive · doi:10.1021/cen-09136-ad11 · Cited by 2,546
Nanoparticles, Proteins, and Nucleic Acids: Biotechnology Meets Materials Science
Niemeyer, C. M. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20011119)40:22<4128::aid-anie4128>3.0.co;2-s · Cited by 2,452
Cited by
Magnetic Nanoparticles: Synthesis, Protection, Functionalization, and Application
Lu, A., Salabas, E. L., & Schüth, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200602866 · Cited by 6,777
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Figuerola, A., Di Corato, R., Manna, L., & Pellegrino, T. (2010) · Pharmacological Research · doi:10.1016/j.phrs.2009.12.012 · Cited by 480
Current investigations into magnetic nanoparticles for biomedical applications
Li, X., Wei, J., Aifantis, K. E., Fan, Y., Feng, Q., Cui, F., & Watari, F. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35654 · Cited by 318
Intrinsic magnetism and hyperthermia in bioactive Fe-doped hydroxyapatite
Tampieri, A., D’Alessandro, T., Sandri, M., Sprio, S., Landi, E., Bertinetti, L., Panseri, S., Pepponi, G., Goettlicher, J., Bañobre-López, M., et al. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.032 · Cited by 302
Magnetische Nanopartikel: Synthese, Stabilisierung, Funktionalisierung und Anwendung
Lu, A., Salabas, E. L., & Schüth, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200602866 · Cited by 266
Brazel, C. S. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9773-2 · Cited by 264
Salloum, M., Ma, R. H., Weeks, D., & Zhu, L. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730801907937 · Cited by 229
“performed a neat experimental study to characterize the movement and heating capacity of magnetic nanoparticles that are uniformly suspended in water, glycerol and collagen [20] in a steady magnetic field as well as an alternating magnetic field.”
BackgroundSensenig, R., Sapir, Y., MacDonald, C., Cohen, S., & Polyak, B. (2012) · Nanomedicine · doi:10.2217/nnm.12.109 · Cited by 229
Quinto, C. A., Mohindra, P., Tong, S., & Bao, G. (2015) · Nanoscale · doi:10.1039/c5nr02718g · Cited by 227
Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound
Oh, J., Feldman, M. D., Kim, J., Condit, C., Emelianov, S., & Milner, T. E. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/16/031 · Cited by 212
“A magnetic field, for example, might be used to induce magnetic hyperthermia to destroy cancer cells in surrounding tissues [33, 34].”
BackgroundSuriyanto, Ng, E. Y. K., & Kumar, S. D. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0327-x · Cited by 205
“the experiment using the collagen to represent the tissue behavior, it was found that by doubling the concentration of particles, the temperature rise was also doubled [110].”
MethodMagnetite nanoparticles with high heating efficiencies for application in the hyperthermia of cancer
Li, Z., Kawashita, M., Araki, N., Mitsumori, M., Hiraoka, M., & Doi, M. (2010) · Materials Science and Engineering: C · doi:10.1016/j.msec.2010.04.016 · Cited by 179
Micro/nanoscale magnetic robots for biomedical applications
Koleoso, M., Feng, X., Xue, Y., Li, Q., Munshi, T., & Chen, X. (2020) · Materials Today Bio · doi:10.1016/j.mtbio.2020.100085 · Cited by 174
In vivo applications of magnetic nanoparticle hyperthermia
Hilger, I. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.832815 · Cited by 172
“Other important physiological factors include the viscosity of circulating blood and of the tumour interstitium, the tumour interstitial pressure, the interaction of nanoparticles with molecular and fibrillar structures, and the shape of the nanoparticles [45,47].”
BackgroundOpen challenges in magnetic drug targeting
Shapiro, B., Kulkarni, S., Nacev, A., Muro, S., Stepanov, P. Y., & Weinberg, I. N. (2015) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1311 · Cited by 171
Optimizing Magnetic Nanoparticle Based Thermal Therapies Within the Physical Limits of Heating
Etheridge, M. L., & Bischof, J. C. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0633-1 · Cited by 64
Self-citationPresent and future of metal nanoparticles in tumor ablation therapy
Lou, W., Xie, L., Xu, L., Xu, M., Xu, F., Zhao, Q., & Jiang, T. (2023) · Nanoscale · doi:10.1039/d3nr04362b · Cited by 33
Metadata
- Authors
- Kalambur, V. S., Han, B., Hammer, B. E., Shield, T. W., & Bischof, J. C.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2005-05-20
- Volume
- 16
- Issue
- 8
- Pages
- 1221-1233
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2090748925
- Cited by
- 175
- References
- 47
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.