Delivery of paclitaxel by physically loading onto poly(ethylene glycol) (PEG)-graftcarbon nanotubes for potent cancer therapeutics
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Physically loading of paclitaxel (PTX) onto carbon nanotubes (CNTs) is achieved through immersion of poly(ethylene glycol) (PEG)-graft-single walled CNTs (PEG-g-SWNTs) or PEG-graft-multi-walled CNTs (PEG-g-MWNTs) in a saturated solution of PTX in methanol. After loading once the loading capacity (LD%) is 26% (w/w) and 36% (w/w) for PEG-g-SWNTs or PEG-g-MWNTs, respectively. With these PTX contents, PTX loaded PEG-g-SWNTs and PTX loaded PEG-g-MWNTs still have good dispersity in aqueous solution and individual CNTs can be observed in TEM images. PTX can be released from PEG-g-CNTs several times faster than from free PTX but still in a sustained profile with less than 40% of PTX being released in 40 days at pH 7 or 5. In vitro cytotoxicity of samples is evaluated in HeLa cells and MCF-7 cells. PEG-g-SWNTs and PEG-g-MWNTs show low cytotoxicity in both cells with insignificant effects on the cell proliferation rates. However, both PTX loaded PEG-g-SWNTs and PTX loaded PEG-g-MWNTs show high efficacy to kill HeLa cells and MCF-7 cells, as reflected by IC(50) lower than free PTX. Therefore, PTX loaded PEG-g-CNTs are promising for cancer therapeutics. KEYWORDS: carbon nanotubes, poly(ethylene glycol), drug delivery, cancer therapy, nanomedicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tasis, D., Tagmatarchis, N., Bianco, A., & Prato, M. (2006) · Chemical Reviews · doi:10.1021/cr050569o · Cited by 4,273 · cited 1×
“However, chemical modification is one of the most feasible approaches to functionalize CNTs for drug delivery [2, 5, 6].”
BackgroundNanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233 · cited 1×
“Also a lot of PTX prodrugs have been reported [33], among which Abraxane formed by conjugating PTX to Human serum albumin has been approved for clinical application recently [33, 43].”
BackgroundApplications of Carbon Nanotubes in Drug Delivery
Kaur, J., Gill, G. S., & Jeet, K. (2019) · Characterization and Biology of Nanomaterials for Drug Delivery · doi:10.1016/b978-0-12-814031-4.00005-2 · Cited by 2,019
Gelderblom, H., Verweij, J., Nooter, K., & Sparreboom, A. (2001) · European Journal of Cancer · doi:10.1016/s0959-8049(01)00171-x · Cited by 1,655
In vivo biodistribution and highly efficient tumour targeting of carbon nanotubes in mice
Liu, Z., Cai, W., He, L., Nakayama, N., Chen, K., Sun, X., Chen, X., & Dai, H. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.170 · Cited by 1,436 · cited 1×
“PEG-g-CNTs, especially with dense PEG brushes [24, 25] or covalently grafted PEG brushes [26], have a long circulation time in the bloodstream because the PEG stealth can escape reticuloendothelial systems (RES) [27].”
BackgroundSupramolecular Chemistry on Water-Soluble Carbon Nanotubes for Drug Loading and Delivery
Liu, Z., Sun, X., Nakayama-Ratchford, N., & Dai, H. (2007) · ACS Nano · doi:10.1021/nn700040t · Cited by 1,368 · cited 9×
“Dox can be adsorbed onto the side walls of CNTs from aqueous solution due to π -stacking interaction, and the weight of adsorbed Dox could be several times higher than that of CNTs [16].”
BackgroundMethodInfluentialDrug Delivery with Carbon Nanotubes for In vivo Cancer Treatment
Liu, Z., Chen, K., Davis, C., Sherlock, S., Cao, Q., Chen, X., & Dai, H. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-1468 · Cited by 1,348
Liu, Z., Davis, C., Cai, W., He, L., Chen, X., & Dai, H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707654105 · Cited by 1,116 · cited 1×
“PEG-g-CNTs, especially with dense PEG brushes [24, 25] or covalently grafted PEG brushes [26], have a long circulation time in the bloodstream because the PEG stealth can escape reticuloendothelial systems (RES) [27].”
BackgroundPolymer Therapeutics: Concepts and Applications
Haag, R., & Kratz, F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502113 · Cited by 1,115 · cited 1×
“Drugs can be conjugated to the side walls of CNTs covalently [19, 20, 31], which is similar to the approach to polymeric prodrugs via conjugating drugs to polymers [32] but using CNTs as substrates instead.”
BackgroundCellular uptake of functionalized carbon nanotubes is independent of functional group and cell type
Kostarelos, K., Lacerda, L., Pastorin, G., Wu, W., Wieckowski, S., Luangsivilay, J., Godefroy, S., Pantarotto, D., Briand, J.-P., Muller, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.209 · Cited by 1,111 · cited 1×
“mechanisms, which might be dependent on the functional groups on the side walls of CNTs [8, 20, 46, 47].”
Background
Cited by
Effective use of nanocarriers as drug delivery systems for the treatment of selected tumors
Din, F. U., Aman, W., Ullah, I., Qureshi, O. S., Mustapha, O., Shafique, S., & Zeb, A. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s146315 · Cited by 1,577
Carbon nanotubes for delivery of small molecule drugs
Wong, B. S., Yoong, S. L., Jagusiak, A., Panczyk, T., Ho, H. K., Ang, W. H., & Pastorin, G. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.08.005 · Cited by 585
Paclitaxel Nano-Delivery Systems: A Comprehensive Review
Ma, P. (2013) · Journal of Nanomedicine & Nanotechnology · doi:10.4172/2157-7439.1000164 · Cited by 559
Nanocarriers for drug delivery applications
Chamundeeswari, M., Jeslin, J., & Verma, M. L. (2019) · Environmental Chemistry Letters · doi:10.1007/s10311-018-00841-1 · Cited by 444
Cancer Nanotechnology: A New Revolution for Cancer Diagnosis and Therapy
Chaturvedi, V. K., Singh, A., Singh, V. K., & Singh, M. P. (2019) · Current Drug Metabolism · doi:10.2174/1389200219666180918111528 · Cited by 418
Carbon nanotubes: a novel material for multifaceted applications in human healthcare
Kumar, S., Rani, R., Dilbaghi, N., Tankeshwar, K., & Kim, K.-H. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00517a · Cited by 397
Carbon Nanotubes in Cancer Therapy and Drug Delivery
Elhissi, A. M. A., Ahmed, W., Hassan, I. U., Dhanak, V. R., & D'Emanuele, A. (2012) · Journal of Drug Delivery · doi:10.1155/2012/837327 · Cited by 332
Carbon nanotubes as cancer therapeutic carriers and mediators
Son, K. H., Hong, J. H., & Lee, J. W. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s112660 · Cited by 292
Prakash, S., Malhotra, M., Shao, W., Tomaro-Duchesneau, C., & Abbasi, S. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.06.013 · Cited by 256
Endowing carbon nanotubes with biological and biomedical properties by chemical modifications
Battigelli, A., Ménard-Moyon, C., Da Ros, T., Prato, M., & Bianco, A. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.006 · Cited by 232
Cancer Targeting and Drug Delivery Using Carbon-Based Quantum Dots and Nanotubes
Pardo, J., Peng, Z., & Leblanc, R. (2018) · Molecules · doi:10.3390/molecules23020378 · Cited by 226
Advances in Lung Cancer Treatment Using Nanomedicines
Sharma, A., Shambhwani, D., Pandey, S., Singh, J., Lalhlenmawia, H., Kumarasamy, M., Singh, S. K., Chellappan, D. K., Gupta, G., Prasher, P., et al. (2023) · ACS Omega · doi:10.1021/acsomega.2c04078 · Cited by 188
Are Carbon Nanotubes a Natural Solution? Applications in Biology and Medicine
Heister, E., Brunner, E. W., Dieckmann, G. R., Jurewicz, I., & Dalton, A. B. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am302902d · Cited by 182
Pharmacokinetics, Metabolism and Toxicity of Carbon Nanotubes for Biomedical Purposes
Yang, S.-T., Luo, J., Zhou, Q., & Wang, H. (2012) · Theranostics · doi:10.7150/thno.3618 · Cited by 182
“Still, drug delivery systems based on PEG-CNTs have been developed at cellular level [37, 38] and in vivo level [39].”
BackgroundToxicity of Carbon Nanotubes as Anti-Tumor Drug Carriers
Yan, H., Xue, Z., Xie, J., Dong, Y., Ma, Z., Sun, X., Kebebe Borga, D., Liu, Z., & Li, J. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s220087 · Cited by 113
Functionalized carbon nanotubes for anticancer drug delivery
Lay, C. L., Liu, J., & Liu, Y. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.34 · Cited by 71
Self-citation
Metadata
- Authors
- Lay, C. L., Liu, H. Q., Tan, H. R., & Liu, Y.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2010-01-08
- Volume
- 21
- Issue
- 6
- Pages
- 065101
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2111442204
- Cited by
- 190
- References
- 47
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.