Magnetic multicore nanoparticles for hyperthermia—influence of particle immobilization in tumour tissue on magnetic properties
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
When using magnetic nanoparticles as a heating source for magnetic particle hyperthermia it is of particular interest to know if the particles are free to move in the interstitial fluid or are fixed to the tumour tissue. The immobilization state determines the relaxation behaviour of the administered particles and thus their specific heating power. To investigate this behaviour, magnetic multicore nanoparticles were injected into experimentally grown tumours in mice and magnetic heating treatment was carried out in an alternating magnetic field (H = 25 kA m(-1), f = 400 kHz). The tested particles were well suited for magnetic heating treatment as they heated a tumour of about 100 mg by about 22 K within the first 60 s. Upon sacrifice, histological tumour examination showed that the particles form spots in the tissue with a mainly homogeneous particle distribution in these spots. The magnetic ex vivo characterization of the removed tumour tissue gave clear evidence for the immobilization of the particles in the tumour tissue because the particles in the tumour showed the same magnetic behaviour as immobilized particles. Therefore, the particles are not able to rotate and a temperature increase due to Brown relaxation can be neglected. To accurately estimate the heating potential of magnetic materials, the respective environments influencing the nanoparticle mobility status have to be taken into account.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A mechanism of magnetic hysteresis in heterogeneous alloys
Stoner, E. C., & Wohlfarth, E. P. (1948) · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences · doi:10.1098/rsta.1948.0007 · Cited by 5,405
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
Hirsch, L. R., Stafford, R. J., Bankson, J. A., Sershen, S. R., Rivera, B., Price, R. E., Hazle, J. D., Halas, N. J., & West, J. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2232479100 · Cited by 3,955
Thermal Fluctuations of a Single-Domain Particle
Brown, W. F. (1963) · Physical Review · doi:10.1103/physrev.130.1677 · Cited by 3,374
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Hyperthermia in combined treatment of cancer
Wust, P., Hildebrandt, B., Sreenivasa, G., Rau, B., Gellermann, J., Riess, H., Felix, R., & Schlag, P. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00818-5 · Cited by 1,998
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470 · cited 12×
“State of the art is the intratumoural injection of MNPs by means of a syringe.”
BackgroundInfluentialMaier-Hauff, K., Ulrich, F., Nestler, D., Niehoff, H., Wust, P., Thiesen, B., Orawa, H., Budach, V., & Jordan, A. (2011) · Journal of Neuro-Oncology · doi:10.1007/s11060-010-0389-0 · Cited by 1,429 · cited 1×
“At present, MHT is entering clinical studies, e.g. for the treatment of prostate cancer (Johannsen et al 2007) or gliomas (Maier–Hauff et al 2010).”
MethodThermal Fluctuations of a Single-Domain Particle
Brown (1963) · Medical Entomology and Zoology · Cited by 1,289
Selective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Size-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038
Magnetic particle hyperthermia—biophysical limitations of a visionary tumour therapy
Hergt, R., & Dutz, S. (2007) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.10.1156 · Cited by 922 · cited 2×
“Based on numerical calculations (Hergt and Dutz 2007) this combination of SHP and particle concentration seems suitable for sufficient heating of the tumour.”
Self-citationJohannsen, M., Gneveckow, U., Thiesen, B., Taymoorian, K., Cho, C. H., Waldöfner, N., Scholz, R., Jordan, A., Loening, S. A., & Wust, P. (2007) · European Urology · doi:10.1016/j.eururo.2006.11.023 · Cited by 532 · cited 1×
“At present, MHT is entering clinical studies, e.g. for the treatment of prostate cancer (Johannsen et al 2007) or gliomas (Maier–Hauff et al 2010).”
MethodEffects of size distribution on hysteresis losses of magnetic nanoparticles for hyperthermia
Hergt, R., Dutz, S., & Röder, M. (2008) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/20/38/385214 · Cited by 311 · cited 12×
“State of the art is the intratumoural injection of MNPs by means of a syringe.”
BackgroundInfluentialSelf-citationHilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A. (2001) · Radiology · doi:10.1148/radiology.218.2.r01fe19570 · Cited by 224 · cited 1×
“Tumour volumes were calculated to be between 60 and 110 mm3, as determined by using the formula V = π/6× (product of three principal diameters) (Hilger et al 2001).”
MethodSelf-citationValidity limits of the Néel relaxation model of magnetic nanoparticles for hyperthermia
Hergt, R., Dutz, S., & Zeisberger, M. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/1/015706 · Cited by 198 · cited 1×
“In numerical calculations, it was shown that the usability of Néel relaxation for MHT purposes is limited (Hergt et al 2010).”
BackgroundSelf-citationFerrofluids of magnetic multicore nanoparticles for biomedical applications
Dutz, S., Clement, J. H., Eberbeck, D., Gelbrich, T., Hergt, R., Müller, R., Wotschadlo, J., & Zeisberger, M. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.073 · Cited by 153 · cited 3×
“…magnetic multicore nanoparticles (MCNP) were used because they show a reasonably high relative remanence Mr/Ms (ratio of remanence Mr to saturation magnetization Ms) combined with moderate coercivity which results in a high specific heating power suitable for MHT, as shown before (Dutz et al 2009).”
MethodResultSelf-citationCsáki, A., Garwe, F., Steinbrück, A., Maubach, G., Festag, G., Weise, A., Riemann, I., König, K., & Fritzsche, W. (2007) · Nano Letters · doi:10.1021/nl061966x · Cited by 102 · cited 1×
“…on plasmonic nanoparticles and laser pulses have been developed and demonstrated at the tissue (Hirsch et al 2003) and even sub-cellular scale (Csaki et al 2007), and showing a highly efficient heat transduction (Garwe et al 2008), optical techniques are less suited for applications inside…”
BackgroundInfluence of dextran coating on the magnetic behaviour of iron oxide nanoparticles
Dutz, S., Andrä, W., Hergt, R., Müller, R., Oestreich, C., Schmidt, C., Töpfer, J., Zeisberger, M., & Bellemann, M. E. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.11.168 · Cited by 74 · cited 1×
“Aqueous suspensions of MCNPs were prepared as described before (Dutz et al 2007, 2009).”
MethodSelf-citationKettering, M., Winter, J., Zeisberger, M., Bremer-Streck, S., Oehring, H., Bergemann, C., Alexiou, C., Hergt, R., Halbhuber, K. J., Kaiser, W. A., et al. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/17/175101 · Cited by 65
Self-citationRichter, H., Kettering, M., Wiekhorst, F., Steinhoff, U., Hilger, I., & Trahms, L. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/3/005 · Cited by 65 · cited 2×
“In a recent magnetorelaxometry (MRX) study for the investigation of the spatial distribution of MNPs injected into living tumours it was found that the particles became fixed to tumour tissue immediately after injection into tumour-bearing mice (Richter et al 2010).”
BackgroundInfluentialSelf-citationOn the calculation of the Neel relaxation time in uniaxial single-domain ferromagnetic particles
Fannin, P. C., & Charles, S. W. (1994) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/27/2/001 · Cited by 63
Magnetic Hyperthermia and Thermoablation
Hergt, R., & Andrä, W. (2006) · doi:10.1002/9783527610174.ch4f · Cited by 50 · cited 1×
“A comprehensive review about the previous research is given by Hergt and Andrä (2007).”
MethodOptically controlled thermal management on the nanometer length scale
Garwe, F., Bauerschaefer, U., Csáki, A., Steinbrück, A., Ritter, K., Bochmann, A., Bergmann, J. W., Weise, A., Akimov, D., Maubach, G., et al. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/05/055207 · Cited by 39 · cited 1×
“…and laser pulses have been developed and demonstrated at the tissue (Hirsch et al 2003) and even sub-cellular scale (Csaki et al 2007), and showing a highly efficient heat transduction (Garwe et al 2008), optical techniques are less suited for applications inside the body than magnetic approaches.”
BackgroundMagnetic Nanoparticles for Biomedical Heating Applications
Dutz, S., Hergt, R., Mürbe, J., Töpfer, J., Müller, R., Zeisberger, M., Andrä, W., & Bellemann, M. E. (2006) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.2006.220.2.145 · Cited by 36 · cited 1×
“The results of the XRD investigations gave information about magnetic phase composition (Dutz et al 2006) and the size of the single crystallites in the clusters by using the Scherrer formula.”
MethodSelf-citation
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Magnetic particle hyperthermia—a promising tumour therapy?
Dutz, S., & Hergt, R. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/45/452001 · Cited by 525
Self-citationDutz, S., & Hergt, R. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.822993 · Cited by 522
Self-citationBranquinho, L. C., Carrião, M. S., Costa, A. S., Zufelato, N., Sousa, M. H., Miotto, R., Ivkov, R., & Bakuzis, A. F. (2013) · Scientific Reports · doi:10.1038/srep02887 · Cited by 395
Physics of heat generation using magnetic nanoparticles for hyperthermia
Dennis, C. L., & Ivkov, R. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.836758 · Cited by 391
Metadata
- Authors
- Dutz, S., Kettering, M., Hilger, I., Müller, R., & Zeisberger, M.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2011-05-17
- Volume
- 22
- Issue
- 26
- Pages
- 265102
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2002556952
- Cited by
- 213
- References
- 24
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.