Micro-systems in biomedical applications
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In this paper we analyse the main characteristics of some micro-devices which have been developed recently for biomedical applications. Among the many biomedical micro-systems proposed in the literature or already on the market, we have selected a few which, in our opinion, represent particularly well the technical problems to be solved, the research topics to be addressed and the opportunities offered by micro-system technology (MST) in the biomedical field. For this review we have identified four important areas of application of micro-systems in medicine and biology: (1) diagnostics; (2) drug delivery; (3) neural prosthetics and tissue engineering; and (4) minimally invasive surgery. We conclude that MST has the potential to play a major role in the development of new medical instrumentation and to have a considerable industrial impact in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Biodegradable Long-Circulating Polymeric Nanospheres
Gref, R., Minamitake, Y., Peracchia, M. T., Trubetskoy, V., Torchilin, V., & Langer, R. (1994) · Science · doi:10.1126/science.8128245 · Cited by 2,920 · cited 1×
“Polymeric nanospheres as nanoparticulate carriers have been investigated for site specific drug delivery by Langer et al [26].”
BackgroundA controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868
Ultrasound-Mediated Transdermal Protein Delivery
Mitragotri, S., Blankschtein, D., & Langer, R. (1995) · Science · doi:10.1126/science.7638603 · Cited by 791 · cited 1×
“Low-frequency ultrasound can make feasible transdermal release of proteins such as insulin, interferon γ and erythropoeitin across human skin [22].”
BackgroundUV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Re-configurable fluid circuits by PDMS elastomer micromachining
Armani, D., Liu, C., & Aluru, N. (1999) · Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291) · doi:10.1109/memsys.1999.746817 · Cited by 382 · cited 1×
“configurable microfluidic circuits [8, 19].”
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301 · cited 2×
“One of the first examples of microelectrodes for recording and stimulating is the probe in silicon (figure 14), for high-amplitude multichannel monitoring of neural activity in the cortex, developed by Najafi et al [29].”
BackgroundA novel mechatronic tool for computer-assisted arthroscopy
Dario, P., Carrozza, M. C., Marcacci, M., D’Attanasio, S., Magnami, B., Tonet, O., & Megali, G. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.826855 · Cited by 145 · cited 1×
“[40].”
Self-citationA single-channel implantable microstimulator for functional neuromuscular stimulation
Ziaie, B., Nardin, M. D., Coghlan, A. R., & Najafi, K. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634643 · Cited by 137 · cited 2×
“Single-channel, implantable microstimulator (from [32]).”
MethodA high-performance silicon micropump for an implantable drug delivery system
Maillefer, D., van Lintel, H., Rey-Mermet, G., & Hirschi, R. (1999) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1999.746886 · Cited by 112 · cited 2×
“Micropump chip developed by Maillefer et al (from [24]).”
BackgroundMethodBuried microchannels in photopolymer for delivering of solutions to neurons in a network
Heuschkel, M. O., Guérin, L., Buisson, B., Bertrand, D., & Renaud, P. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00071-9 · Cited by 109 · cited 1×
“Smart microchips for culture, stimulation, and recording of neural cells arrays have also been developed [31].”
MethodAn implantable drug-delivery system based on shape memory alloy micro-actuation
Reynaerts, D., Peirs, J., & BRUSSEL, H. V. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80305-6 · Cited by 95 · cited 1×
“Active implantable devices for both solid and liquid drug delivery, actuated by shape memory alloys, have been developed by Reynaerts et al [23].”
BackgroundMicrofabricated Biocapsules Provide Short-Term Immunoisolation of Insulinoma Xenografts
Desai, T. A., Chu, W. H., Rasi, G., Vallebona, P. S., Guarino, E., & Mauro Ferrari, B. (1999) · Biomedical Microdevices · doi:10.1023/a:1009948524686 · Cited by 89 · cited 2×
“Microfabricated biocapsules [27] as in vivo insulinsecreting bioreactors have been developed.”
BackgroundDroplet-based nano/picoliter mixer using hydrophobic microcapillary vent
Hosokawa, K., Fujii, T., & Endo, I. (1999) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1999.746860 · Cited by 60 · cited 1×
“In order to overcome these problems, microfluidic devices based on discrete flows have been developed [7].”
BackgroundNeural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58 · cited 1×
“The interface is comprised of three components (figure 17): a microfabricated silicon die with microelectrode array on multiple through holes, a polymer guidance channel housing the die, and a flexible flat cable connecting the die to external electronic circuitry [34].”
MethodSelf-citationDario, P., Carrozza, M. C., Allotta, B., & Guglielmelli, E. (1996) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/3516.506150 · Cited by 56 · cited 2×
“In a previous paper we presented an analysis of MST and micromechatronic devices for biomedical applications [1].”
BackgroundMethodSelf-citationModelling of micropumps using unimorph piezoelectric actuator and ball valves
Accoto, D., Carrozza, M. C., & Dario, P. (2000) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/10/2/329 · Cited by 51 · cited 1×
“Bubbles are often found in small channels, but this problem can be turned into a positive effect if the bubbles are used to separate fluidic boluses or even act as pumps and valves [6].”
BackgroundSelf-citationNeuro-electronic interfacing with multielectrode arrays
Rutten, W. L. C., Smit, J. P. A., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L. H., Buitenweg, J. R., & Heida, C. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765188 · Cited by 39 · cited 4×
“Array of microneedles for selective nerve stimulation (from [33]).”
BackgroundMethodInfluentialSilicon cultured-neuron prosthetic devices for in vivo and in vitro studies
Tatić-Lučić, S., Wright, J. A., Tai, Y., & Pine, J. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00143-3 · Cited by 25 · cited 1×
“Silicon micromachined structures, in which cultured neurons can be implanted and grown, are described in [30].”
BackgroundDNA Analysis in Microfabricated Formats
Abramowitz, S. (1999) · Biomedical Microdevices · doi:10.1023/a:1009992306940 · Cited by 17 · cited 2×
“However, this development requires that a number of theoretical and technological problems in such areas as microfluidics, micromachining, microchemistry and biosensing are overcome [4].”
BackgroundMethodA multipolar precision hybrid cuff electrode for FES on large peripheral nerves
Schüettler, M., Stieglitz, T., & Meyer, J.-U. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1999.802460 · Cited by 6 · cited 1×
“A different approach for interfacing peripheral nerves consists of cuff-type connectors, such as those fabricated by Schuettler et al [35].”
Method
Cited by
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Fundamentals, processes and applications of high-permittivity polymer–matrix composites
Dang, Z.-M., Yuan, J.-K., Zha, J.-W., Zhou, T., Li, S.-T., & Hu, G.-H. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.08.001 · Cited by 1,783
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
An all-organic composite actuator material with a high dielectric constant
Zhang, Q. M., Li, H., Poh, M., Xia, F., Cheng, Z.-Y., Xu, H., & Huang, C. (2002) · Nature · doi:10.1038/nature01021 · Cited by 1,073
Converging Technologies for Improving Human Performance
(2003) · Springer eBooks · doi:10.1007/978-94-017-0359-8 · Cited by 794
Metadata
- Authors
- Dario, P., Carrozza, M. C., Benvenuto, A., & Menciassi, A.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2000-05-23
- Volume
- 10
- Issue
- 2
- Pages
- 235-244
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2076788760
- Cited by
- 191
- References
- 21
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.