The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A high-yield IC-compatible multichannel recording array
Abstract
This paper reports the development of a multielectrode recording array for use in studies of information processing in the central nervous system and in the closed-loop control of neural prostheses. The probe utilizes a silicon supporting carrier which is defined using a deep boron diffusion and an anisotropic etch stop. This substrate supports an array of polysilicon or tantalum thin-film conductors insulated above and below with silicon nitride and silicon dioxide. Typical probe dimensions include a length of 3 mm, shank width of 50 µm, and a thickness of 15 µm. These structures are capable of simultaneous high-amplitude multichannel recording of neural activity in the cortex. The probe fabrication process requires only four masks and is single-sided using wafers of normal thickness, resulting in yields which exceed 80 percent. The process is also compatible with the inclusion of on-chip MOS circuitry for signal amplification and multiplexing. A complete ten-channel signal processor which requires only three external probe leads is being developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citation
Research works printed but not linked: 11
- 1977, Functional Electrical Stimulation Applications in Neural Prostheses
- 10.1109/PROC.1968.6458 · DOI · Paper page
- delahay, 1965, Double Layer and Electrode Kinetics
- 10.1109/TBME.1973.324194 · DOI
- 10.1109/T-ED.1980.20087 · DOI
- wise, 1984, A micromachined integrated sensor with on-chip self-test capability, Tech Dig IEEE Solid State Sensor Conf, 12
- 10.1016/0250-6874(84)87009-2 · DOI
- 10.1109/TBME.1975.324562 · DOI
- 10.1109/JRPROC.1959.287156 · DOI · Paper page
- 10.1149/1.2426793 · DOI
- frank, 1964, Physical Techniques in Biological Research, 5
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Self-citationAn implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citation
Metadata
- Authors
- Najafi, K., Wise, K. D., & Mochizuki, T.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1985-07
- Volume
- 32
- Issue
- 7
- Pages
- 1206-1211
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2045701127
- Cited by
- 301
- References
- 1
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A high-yield IC-compatible multichannel recording array. https://app.cochat.ai/papers/10.1109/t-ed.1985.22102
- The paper
- Najafi, K., Wise, K. D., & Mochizuki, T. (1985). A high-yield IC-compatible multichannel recording array. IEEE Transactions on Electron Devices. https://doi.org/10.1109/t-ed.1985.22102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.