The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
PDMS-based micro PCR chip with Parylene coating
Abstract
We have developed a microchip for polymerase chain reaction (PCR) with polydimethylsiloxane (PDMS). PDMS has good characteristics: it is cheap, transparent, easy to fabricate and biocompatible. But in micro PCR, the porosity of PDMS causes several critical problems such as bubble formation, sample evaporation and protein adsorption. To solve those problems, we coated the micro PCR chips with Parylene film, which has low permeability to moisture and long-term stability. We investigated the influence of low thermal conductivity of PDMS and Parylene on the thermal characteristics of the PCR chips with numerical analysis. The thermal responses of micro PCR chips were compared for three materials: silicon, glass and PDMS. From the results, we identified appropriate thermal responses of the PDMS-based micro PCR chips by heating both the top and bottom sides. We could successfully amplify the angiotensin converting enzyme gene with as small a volume as 2 μl on the PDMS-based micro PCR chips without any additives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
Single-Molecule DNA Amplification and Analysis in an Integrated Microfluidic Device
Lagally, E. T., Medintz, I. L., & Mathies, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac001026b · Cited by 430
Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges
Hillborg, H., & Gedde, U. W. (1998) · Polymer · doi:10.1016/s0032-3861(97)00484-9 · Cited by 430
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
Flow-through polymerase chain reactions in chip thermocyclers
Schneegaß, I., & Köhler, J. M. (2001) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00033-2 · Cited by 99
Kim, D. S., Choi, S. I., Lee, H. S., Park, J. K., & Yi, H. K. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.004 · Cited by 34
Cited by
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Self-citationFang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Metadata
- Authors
- Shin, Y. S., Cho, K., Lim, S. H., Chung, S., Park, S.-J., Chung, C., Han, D.-C., & Chang, J. K.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2003-06-20
- Volume
- 13
- Issue
- 5
- Pages
- 768-774
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W1964346108
- Cited by
- 330
- References
- 7
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PDMS-based micro PCR chip with Parylene coating. https://app.cochat.ai/papers/10.1088/0960-1317/13/5/332
- The paper
- Shin, Y. S., Cho, K., Lim, S. H., Chung, S., Park, S.-J., Chung, C., Han, D.-C., & Chang, J. K. (2003). PDMS-based micro PCR chip with Parylene coating. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/13/5/332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.