Mechanical properties of silicones for MEMS
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This paper focuses on the mechanical properties of polydimethylsiloxane (PDMS) relevant for microelectromechanical system (MEMS) applications. In view of the limited amount of published data, we analyzed the two products most commonly used in MEMS, namely RTV 615 from Bayer Silicones and Sylgard 184 from Dow Corning. With regard to mechanical properties, we focused on the dependence of the elastic modulus on the thinner concentration, temperature and strain rate. In addition, creep and thermal aging were analyzed. We conclude that the isotropic and constant elastic modulus has strong dependence on the hardening conditions. At high hardening temperatures and long hardening time, RTV 615 displays an elastic modulus of 1.91 MPa and Sylgard 184 of 2.60 MPa in a range up to 40% strain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Creep and Relaxation of Nonlinear Viscoelastic Materials
(1976) · North-Holland Series in Applied Mathematics and Mechanics · doi:10.1016/b978-0-7204-2369-3.x5001-2 · Cited by 887
The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
Lötters, J. C., Olthuis, W., Veltink, P. H., & Bergveld, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/017 · Cited by 827
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Photophysics and photochemistry of oxygen sensors based on luminescent transition-metal complexes
Carraway, E. R., Demas, J. N., DeGraff, B. A., & Bacon, J. R. (1991) · Analytical Chemistry · doi:10.1021/ac00004a007 · Cited by 638
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Choi, K. M., & Rogers, J. A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029973k · Cited by 309
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Chemical cytometry on a picoliter-scale integrated microfluidic chip
Wu, H., Wheeler, A., & Zare, R. N. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405299101 · Cited by 241
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
Tactile sensor arrays using fiber Bragg grating sensors
Heo, J.-S., Chung, J.-H., & Lee, J.-J. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.10.048 · Cited by 192
Cited by
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Kim, D.-H., Song, J., Choi, W. M., Kim, H.-S., Kim, R.-H., Liu, Z., Huang, Y. Y., Hwang, K.-C., Zhang, Y.-W., & Rogers, J. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807476105 · Cited by 737
Tee, B. C. ‐., Chortos, A., Dunn, R. R., Schwartz, G., Eason, E., & Bao, Z. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400712 · Cited by 538
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Metadata
- Authors
- Schneider, F., Fellner, T., Wilde, J., & Wallrabe, U.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2008-04-29
- Volume
- 18
- Issue
- 6
- Pages
- 065008
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2091631730
- Cited by
- 435
- References
- 15
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.