CoChat

Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recording

Herwik, S, Kisban, S, Aarts, A A A, Seidl, K, Girardeau, G, Benchenane, K, Zugaro, M B, Wiener, S I, Paul, O, Neves, H P, Ruther, P · 2009 · Journal of Micromechanics and Microengineering
Cited by 115

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This work presents a new fabrication technology for silicon-based neural probe devices and their assembly into two-dimensional (2D) as well as three-dimensional (3D) microprobe arrays for neural recording. The fabrication is based on robust double-sided deep reactive ion etching of standard silicon wafers and allows full 3D control of the probe geometry. Wafer level electroplating of gold pads was performed to improve the 3D assembly into a platform. Lithography-based probe-tracking features for quality management were introduced. Probes for two different assembly methods, namely direct bonding to a flexible micro-cable and platform-based out-of-plane interconnection, were produced. Systems for acute and sub-chronic recordings were assembled and characterized. Recordings from rats demonstrated the recording capability of these devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0960-1317/19/7/074008

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 115

Metadata

Authors
Herwik, S., Kisban, S., Aarts, A. A. A., Seidl, K., Girardeau, G., Benchenane, K., Zugaro, M. B., Wiener, S. I., Paul, O., Neves, H. P., & Ruther, P.
Venue
Journal of Micromechanics and Microengineering
Published
2009-06-30
Volume
19
Issue
7
Pages
074008
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W2036572805
Cited by
115
References
5
FWCI
5.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recording. https://app.cochat.ai/papers/10.1088/0960-1317/19/7/074008
The paper
Herwik, S., Kisban, S., Aarts, A. A. A., Seidl, K., Girardeau, G., Benchenane, K., Zugaro, M. B., Wiener, S. I., Paul, O., Neves, H. P., & Ruther, P. (2009). Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recording. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/19/7/074008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.