Stretchable gold conductors embedded in PDMS and patterned by photolithography: fabrication and electromechanical characterization
Open accessThe DOI matches its Crossref record.
Abstract
Stretchable gold conductors embedded in polydimethylsiloxane (PDMS) films were successfully prepared using standard photolithography. The minimum feature sizes patterned in the metal film and PDMS encapsulation are 10 µm and 20 µm, respectively. The micro-patterned conductors are robust to uni-axial (1D) and radial (2D) stretching with applied strains of tens of percent. The electrical response of the conductors follows a nonlinear increase with strain, and is reversible. The extensive stretchability of the conductors relies on a randomly and independently distributed network of micro-cracks (∼100 nm long) in the metal film on PDMS. The micro-cracks elongate to a few microns length both in the stretching and normal directions in 1D stretching but during 2D stretching, the micro-cracks grow and form ‘dry mud’ islands leaving the gold microstructure inside the islands intact. Patterning metallic thin films directly onto elastomeric substrates opens a promising route for microelectrodes and interconnects for soft and ultra-compliant MEMS and electronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
Mimosa‐Inspired Design of a Flexible Pressure Sensor with Touch Sensitivity
Su, B., Gong, S., Ma, Z., Yap, L. W., & Cheng, W. (2015) · Small · doi:10.1002/smll.201403036 · Cited by 383
A Highly Sensitive Capacitive-type Strain Sensor Using Wrinkled Ultrathin Gold Films
Nur, R., Matsuhisa, N., Jiang, Z., Nayeem, M. O. G., Yokota, T., & Someya, T. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b02088 · Cited by 307
Recent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
Self-citationFlexible microfluidic normal force sensor skin for tactile feedback
Ponce Wong, R. D., Posner, J. D., & Santos, V. J. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.03.023 · Cited by 251
Flexible and stretchable nanowire-coated fibers for optoelectronic probing of spinal cord circuits
Lu, C., Park, S., Richner, T. J., Derry, A., Brown, I., Hou, C., Rao, S., Kang, J., Moritz, C. T., Fink, Y., et al. (2017) · Science Advances · doi:10.1126/sciadv.1600955 · Cited by 223
Softening gold for elastronics
Zhu, B., Gong, S., & Cheng, W. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00609a · Cited by 216
Xie, M., Zhang, Y., Kraśny, M. J., Bowen, C., Khanbareh, H., & Gathercole, N. (2018) · Energy & Environmental Science · doi:10.1039/c8ee01551a · Cited by 193
Stretchable electronics: materials, architectures and integrations
Ahn, J.-H., & Je, J. H. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/10/103001 · Cited by 180
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Glove-based sensors for multimodal monitoring of natural sweat
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A. (2020) · Science Advances · doi:10.1126/sciadv.abb8308 · Cited by 154
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“The conductive plates are commonly fabricated by utilizing deposition techniques like electroplating, evaporation, or The conductive plates are commonly fabricated by utilizing deposition techniques like electroplating, evaporation, or sputtering [145–147]. sputtering [145–147].”
MethodMinev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026005 · Cited by 36
Self-citation
Metadata
- Authors
- Adrega, T., & Lacour, S. P.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2010-04-23
- Volume
- 20
- Issue
- 5
- Pages
- 055025
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W1987958853
- Cited by
- 157
- References
- 0
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.