CoChat

High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of -58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s(-1). The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.

Overview

Integrity signals

Registry

Crossref · 10.1088/1741-2560/9/2/026005

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. Clark G A Ledbetter N M Warren D J Harrison R R, 2011, 33rd Annu. Int. Conf. of the IEEE EMBS, 4641

Cited by

See all 36

Metadata

Authors
Minev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P.
Affiliations
  • University of Cambridge (GB)
  • École Polytechnique Fédérale de Lausanne (CH)
Venue
Journal of Neural Engineering
Published
2012-02-13
Volume
9
Issue
2
Pages
026005
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2168977771
Cited by
36
References
32
Citations by year
2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 4 · 2015: 6 · 2014: 4 · 2013: 4 · 2012: 2
FWCI
2.09
Type
journal article
Language
en
Open access
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Funders
  • Royal Society
  • Engineering and Physical Sciences Research Council (EP/H00727X/1)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
neural prostheses, peripheral nerve interfaces, signal-to-noise ratio
MeSH terms
Animals, Dimethylpolysiloxanes, Electrodes, Implanted, Electrophysiology, Gold, Male, Microelectrodes, Neurons, Afferent, Peripheral Nerves, Physical Stimulation, Prosthesis Design, Robotics, Spinal Cord, User-Computer Interface, Reproducibility of Results, Electric Impedance, Rats, Sprague-Dawley, Rats, Neural Prostheses, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation. https://app.cochat.ai/papers/10.1088/1741-2560/9/2/026005
The paper
Minev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P. (2012). High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/9/2/026005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.