A microsystem-based assay for studying pollen tube guidance in plant reproduction
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present a novel microsystem-based assay to assess and quantify pollen tube behavior in response to pistil tissues. During plant reproduction, signals from female tissues (pistils) guide the sperm-carrying pollen tube to the egg cell to achieve fertilization and initiate seed development. Existing pollen tube guidance bioassays are performed in an isotropically diffusive environment (for example, a semi in vivo assay in petri dishes) instead of anisotropically diffusive conditions required to characterize guidance signal gradients. Lack of a sensitive pollen tube guidance bioassay has therefore compounded the difficulties of identifying and characterizing the guidance signals that are likely produced in minute quantities by the ovules. We therefore developed a novel microsystem-based assay that mimics the in vivo micro-environment of ovule fertilization by pollen tubes in the model research plant Arabidopsis thaliana. In this microdevice, the pollen tube growth rate, length and ovule targeting frequencies were similar to those obtained using a semi in vivo plate assay. As a direct measure of the microdevice's utility in monitoring pollen tube guidance, we demonstrated that in this device, pollen tubes preferentially enter chambers with unfertilized ovules, suggesting that the pollen tubes sense the concentration gradient and respond to the chemoattractants secreted by unfertilized ovules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Cited by
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Self-citationMicro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Holographic Sensors: Three-Dimensional Analyte-Sensitive Nanostructures and Their Applications
Yetisen, A. K., Naydenova, I., da Cruz Vasconcellos, F., Blyth, J., & Lowe, C. R. (2014) · Chemical Reviews · doi:10.1021/cr500116a · Cited by 224
Self-citationKovarik, M. L., Ornoff, D. M., Melvin, A. T., Dobes, N. C., Wang, Y., Dickinson, A. J., Gach, P. C., Shah, P. K., & Allbritton, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac3031543 · Cited by 218
Photonic Nanosensor for Colorimetric Detection of Metal Ions
Yetisen, A. K., Montelongo, Y., Qasim, M. M., Butt, H., Wilkinson, T. D., Monteiro, M. J., & Yun, S. H. (2015) · Analytical Chemistry · doi:10.1021/ac504274q · Cited by 94
Self-citation
Metadata
- Authors
- Yetisen, A. K., Jiang, L., Cooper, J. R., Qin, Y., Palanivelu, R., & Zohar, Y.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2011-04-28
- Volume
- 21
- Issue
- 5
- Pages
- 054018
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W1968784064
- Cited by
- 63
- References
- 1
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.