Practical issues related to the application of the electromechanical impedance technique in the structural health monitoring of civil structures: I. Experiment
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The advent of smart materials such as the piezo-impedance transducer (lead zirconate titanate, PZT) and optical fiber (FBG) has ushered in a new era in the field of structural health monitoring (SHM) based on non-destructive evaluation (NDE). So far, successful research and investigations conducted on the electromechanical impedance (EMI) technique employing a piezo-impedance transducer are often laboratory based and mainly theoretical. Real-life application of the technique, especially under harsh environments, has frequently been questioned. In this research project, investigative studies were conducted to evaluate the problems involved in real-life applications of the EMI technique, attempting to reduce the gap between theory and application. This two-part paper presents a series of experimentation (part I) and numerical verification (part II) on various issues related to real-life application, including the durability of PZT transducers, and the effects of bonding and temperature under conceivable nominal construction site conditions. The repeatability of electrical admittance signatures acquired from the PZT patches surface bonded on aluminum structures was found to be excellent up to a period of one and a half years. Experimental investigations revealed that the bonding thickness should preferably be thinner than one-third of the patch to avoid any adverse effect caused by the PZT patch's resonance on the admittance signatures which reflect the host structural behavior. On the other hand, the effect of temperature on the admittance signatures was found to be closely related to the thickness of bonding, as an increase in temperature would reduce the stiffness of the bonding layer, thus affecting strain transfer. It was concluded that PZT patches with thick bonding thickness and high frequency of excitation are undesirable, especially at elevated temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790 · cited 1×
“Xu and Liu (2003) incorporated the effect of bonding into the one-dimensional impedance based electromechanical model (Liang et al 1994) by simplifying the bonding layer into a single spring–mass–damper system.”
BackgroundImpedance-Based Health Monitoring of Civil Structural Components
Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2000)6:4(153 · Cited by 460 · cited 1×
“…and Soh 2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007, 2008a, 2008b) related to the EMI technique have been…”
MethodStructural Health Monitoring by Piezo-Impedance Transducers. I: Modeling
Bhalla, S., & Soh, C. K. (2004) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2004)17:4(154 · Cited by 351 · cited 2×
“Bhalla and Soh (2004) proposed a two-dimensional effective impedance based model inclusive of the bonding layer and concluded that the effect of bonding could be omitted for most engineering models.”
BackgroundSelf-citationImpedance-Based Structural Health Monitoring for Temperature Varying Applications.
PARK, G., KABEYA, K., CUDNEY, H. H., & INMAN, D. J. (1999) · JSME International Journal Series A · doi:10.1299/jsmea.42.249 · Cited by 284 · cited 6×
“Park et al (1999) illustrated that a temperature change imposes a major effect on the dielectric constant and piezoelectric coupling constant of the patch.”
BackgroundMethodInfluentialQualitative impedance-based health monitoring of civil infrastructures
Ayres, J. W., Lalande, F., Chaudhry, Z., & Rogers, C. A. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/5/004 · Cited by 232 · cited 1×
“…et al 1996, Bhalla and Soh 2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007, 2008a, 2008b) related to the EMI technique…”
MethodElectro-mechanical impedance modeling of active material systems
Liang, C., Sun, F., & Rogers, C. A. (1996) · Smart Materials and Structures · doi:10.1088/0964-1726/5/2/006 · Cited by 224 · cited 1×
“Various issues such as EMI modeling (Liang et al 1996, Bhalla and Soh 2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007,…”
BackgroundSensitivity of PZT Impedance Sensors for Damage Detection of Concrete Structures
Yang, Y., Hu, Y., & Lu, Y. (2008) · Sensors · doi:10.3390/s8010327 · Cited by 224 · cited 1×
“…2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007, 2008a, 2008b) related to the EMI technique have been extensively studied.”
MethodSelf-citationXu, Y. G., & Liu, G. R. (2002) · Journal of Intelligent Material Systems and Structures · doi:10.1177/104538902761696733 · Cited by 172
Damage Identification in Aging Aircraft Structures with Piezoelectric Wafer Active Sensors
Giurgiutiu, V., Zagrai, A., & Bao, J. (2004) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x04038051 · Cited by 165
Bhalla, S. (2004) · DR-NTU (Nanyang Technological University) · Cited by 115
Influence of loading on the electromechanical admittance of piezoceramic transducers
Annamdas, V. G. M., Yang, Y., & Soh, C. K. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/5/045 · Cited by 111 · cited 1×
“Various issues such as EMI modeling (Liang et al 1996, Bhalla and Soh 2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007,…”
BackgroundSelf-citationPiezoelectric Materials at Elevated Temperature
Schulz, M. J., Sundaresan, M. J., Mcmichael, J., Clayton, D., Sadler, R. L., & Nagel, B. (2003) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x03038577 · Cited by 102 · cited 1×
“Schulz et al (2003) reported that the piezoelectric properties decrease with increasing temperature but recover each time the sensor is cooled.”
BackgroundApplication of Multiplexed FBG and PZT Impedance Sensors for Health Monitoring of Rocks
Yang, Y., Annamdas, V. G. M., Wang, C., & Zhou, Y. (2008) · Sensors · doi:10.3390/s8010271 · Cited by 86 · cited 1×
“…2004, Yang et al 2005, Annamdas et al 2007, Yang and Hu 2008), PZT sensing region (Hu and Yang 2007), and applications (Ayres et al 1998, Park et al 2000a, 2000b, Xu et al 2004, Giurgiutiu et al 2004a, 2004b, Yang et al 2007, 2008a, 2008b) related to the EMI technique have been extensively studied.”
MethodSelf-citationEffects of temperature on the electrical impedance of piezoelectric sensors
Krishnamurthy, K., Lalande, F., & Rogers, C. A. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.239033 · Cited by 49
Cited by
Na, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Annamdas, V. G. M., & Soh, C. K. (2010) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x09352816 · Cited by 218
“It should also be kept away from atmospheric influences (like humidity, moisture, and temperature) (Yang et al., 2008a,b), acidic/alkaline attacks (due to rain or sea water exposures), and electrical or magnetic zone (Lin et al., 1988).”
InfluentialSelf-citationParida, L., Moharana, S., Ferreira, V. M., Giri, S. K., & Ascensão, G. (2022) · Sensors · doi:10.3390/s22249920 · Cited by 58
“Similar studies have been reported by researchers in their work to investigate the hydration monitoring process using structural and piezo resonance peaks [103,104].”
Result
Metadata
- Authors
- Yang, Y., Lim, Y. Y., & Soh, C. K.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2008-03-31
- Volume
- 17
- Issue
- 3
- Pages
- 035008
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2011406035
- Cited by
- 162
- References
- 15
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.