CoChat

Functional electrical stimulation

Open access
Rushton, D N · 1997 · Physiological Measurement
Cited by 101

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

In the health-care professions, electrical stimulation is used for three purposes: to aid diagnosis; as a therapeutic tool; and to restore lost or damaged functions. Functional electrical stimulation (FES) and functional neurostimulation (FNS) are terms which are more or less interchangeable, and which encompass the third of these purposes. FES itself can also be conveniently divided into three classes, according to purpose: the restoration of sensor functions; the restoration of skeleto-motor functions; and the restoration of autonomic functions. Potentially, a fourth class would comprise devices restoring cognitive or psychological functions, but no such devices are clinically available as yet. The methods and devices which are currently available for providing FES are reviewed, as are the sorts of result and benefit that may be expected from them. The structure and emphasis of the review is on the clinical applications and the relevant anatomical and neurophysiological considerations and this approach is chosen for two main reasons. Firstly, the clinical, anatomical, and physiological considerations are independent of technological change and development, so they will not become quickly out of date. Secondly, the author is a clinician by profession, and an engineer only by inclination. The functional aims of FES methods will continue to develop as a result of experience gained following the introduction and use of successful devices, and these evolutionary improvements will come from within the FES programme; but the engineering embodiment of those devices may be revolutionized at any time by technological advances coming from elsewhere.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/18/4/001

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 101

Metadata

Authors
Rushton, D. N.
Venue
Physiological Measurement
Published
1997-11-01
Volume
18
Issue
4
Pages
241-275
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2004836665
Cited by
101
References
9
FWCI
0.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional electrical stimulation. https://app.cochat.ai/papers/10.1088/0967-3334/18/4/001
The paper
Rushton, D. N. (1997). Functional electrical stimulation. Physiological Measurement. https://doi.org/10.1088/0967-3334/18/4/001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.