Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper, the influences of overlying tissue and detecting distance between the source and the detector on the measurement of a tissue oximeter were discussed. The signal-noise-ratio of the detector was also examined. A semi-infinite multi-layer Monte Carlo model was induced to simulate the migration of the photons in the skin, adipose and muscle. The thickness of the adipose layer and the separation between the source and the detector in the muscle were changed to simulate the clinical application. Partial pathlength was introduced as a characteristic parameter to evaluate the sensitivity of the oximeter. A two-wavelength (700 and 830 nm) tissue oximeter was developed to verify the results of the simulation. The Monte Carlo simulation results showed that the sensitivity of the near infrared spectroscopy (NIRS) oximeter declined greatly with increasing overlying tissue thickness. Increasing the distance between the light source and the detector improved the sensitivity. However, in order to achieve a sufficiently high signal-to-noise ratio, it was necessary to limit this distance. The results of a bicycle ergometer exercise verified the above results and showed that, for a special adipose thickness (AT), there may be a reasonable range of the emitter-detector separation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
An, L., Qin, J., & Wang, R. K. (2010) · Optics Express · doi:10.1364/oe.18.008220 · Cited by 291
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
Metadata
- Authors
- Feng, W., Haishu, D., Fenghua, T., Jun, Z., Qing, X., & Xianwu, T.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2001-02-01
- Volume
- 22
- Issue
- 1
- Pages
- 201-208
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2092574075
- Cited by
- 53
- References
- 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter. https://app.cochat.ai/papers/10.1088/0967-3334/22/1/323
- The paper
- Feng, W., Haishu, D., Fenghua, T., Jun, Z., Qing, X., & Xianwu, T. (2001). Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter. Physiological Measurement. https://doi.org/10.1088/0967-3334/22/1/323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.