The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds
Open accessAbstract
In this paper, we demonstrate for the first time that the detailed cutaneous blood flow at capillary level within dermis of human skin can be imaged by optical micro-angiography (OMAG) technique. A novel scanning protocol, i.e. fast B scan mode is used to achieve the capillary flow imaging. We employ a 1310nm system to scan the skin tissue at an imaging rate of 300 frames per second, which requires only ~5 sec to complete one 3D imaging of capillary blood flow within skin. The technique is sensitive enough to image the very slow blood flows at ~4 microm/sec. The promising results show a great potential of OMAG's role in the diagnosis, treatment and management of human skin diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Speckle variance detection of microvasculature using swept-source optical coherence tomography
Mariampillai, A., Standish, B. A., Moriyama, E. H., Khurana, M., Munce, N. R., Leung, M. K. K., Jiang, J., Cable, A., Wilson, B. C., Vitkin, I. A., et al. (2008) · Optics Letters · doi:10.1364/ol.33.001530 · Cited by 699
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Self-citationThe Cutaneous Microcirculation
Braverman, I. M. (2000) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1046/j.1087-0024.2000.00010.x · Cited by 486
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
Self-citationIn vivo full range complex Fourier domain optical coherence tomography
Wang, R. K. (2007) · Applied Physics Letters · doi:10.1063/1.2437682 · Cited by 151
Self-citation
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Doppler Optical Coherence Tomography
Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.03.004 · Cited by 444
Metadata
- Authors
- An, L., Qin, J., & Wang, R. K.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-04-05
- Volume
- 18
- Issue
- 8
- Pages
- 8220
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2043612250
- Cited by
- 291
- References
- 13
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds. https://app.cochat.ai/papers/10.1364/oe.18.008220
- The paper
- An, L., Qin, J., & Wang, R. K. (2010). Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds. Optics Express. https://doi.org/10.1364/oe.18.008220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.