Increase of acetone and ammonia in urine headspace and breath during ovulation quantified using selected ion flow tube mass spectrometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Selected ion flow tube mass spectrometry (SIFT-MS) has been used for a detailed study of the daily variations in the acetone and ammonia content of the headspace above urine from a healthy female subject over the course of three separate menstrual cycles. Midstream urine samples were taken every morning prior to any food intake and the headspace subsequently analysed for a number of metabolites. Concurrent with the time of ovulation, a 3-to- 12-fold increase in the level of acetone in the urine headspace was observed. The successive peaks in acetone level and the subsequent return to baseline values were mirrored by similar increases in the ammonia levels, but these were a day out of phase. Interestingly, parallel breath analyses at ovulation showed no great increase in either acetone or ammonia above their normal morning levels, suggesting that these metabolites had been removed from the body during the night by the usual metabolic and physiological processes. The results of this study reveal what may be an important phenomenon at the time of ovulation and illustrate the potential and power of online SIFT-MS analysis in this area of research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citation24-hour energy expenditure and the menstrual cycle
Webb, P. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.5.614 · Cited by 237
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Self-citationReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citationProgress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Self-citation
Metadata
- Authors
- Diskin, A. M., Spanel, P., & Smith, D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2003-01-17
- Volume
- 24
- Issue
- 1
- Pages
- 191-199
- ISSN
- 0967-3334 (ISSN-L)
- OpenAlex
- W2031646983
- Cited by
- 46
- References
- 2
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.