The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements
Open accessAbstract
The cardio-respiratory signal is a fundamental vital sign used for assessment of a patient's status. Additionally, the cardio-respiratory signal provides a great deal of information to healthcare providers wishing to monitor healthy individuals. The air mattress sensor system allows the measurement of the respiration and heart beat movements without the use of a harness or sensor on the subject's body, which eliminates the difficulties these pose for long term measurements. In order to increase the sensitivity, a differential measurement technique between two air cells was used. The concept of a balancing tube between two air cells is suggested in order to increase the robustness against postural changes during the measurements. With this balancing tube, the meaningful frequency range could be selected using a pneumatic method. A mathematical model was constructed and validation experiments were performed for step and sinusoidal input signals. This technique was applied to measurements of respiration and heart beat movements in the supine posture on the bed, which showed potential for applications in sleep analysis, unconstrained healthcare monitoring and neonate monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Body movements, breathing and even cardiac activities can be detected by the volume change of the pneumatic underneath an individual whilst they are lying in bed52–54.”
From The future of sleep health: a data-driven revolution in sleep science and medicine (2020) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Heart Rate Variability During Waking and Sleep in Healthy Males and Females
Elsenbruch, S., Harnish, M. J., & Orr, W. C. (1999) · SLEEP · doi:10.1093/sleep/22.8.1067 · Cited by 219
Noncontact Method for Sleep Stage Estimation
Watanabe, T., & Watanabe, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828037 · Cited by 148
A smart bed for non-intrusive monitoring of patient physiological factors
SpillmanJr, W. B., Mayer, M., Bennett, J., Gong, J., Meissner, K. E., Davis, B. A., Claus, R. O., MuelenaerJr, A. A., & Xu, X. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/8/032 · Cited by 98
Tanaka, S., Matsumoto, Y., & Wakimoto, K. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348132 · Cited by 52
The Nature of Respiratory Changes Associated with Sleep Onset
Naifeh, K. H., & Kamiya, J. (1981) · SLEEP · doi:10.1093/sleep/4.1.49 · Cited by 51
Respiratory monitoring using an air-mattress system
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/301 · Cited by 45
Characterization of a novel heart and respiratory rate sensor
Jacobs, J. L., Embree, P., Glei, M., Christensen, S., & Sullivan, P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403648 · Cited by 39
A new non-invasive approach for monitoring respiratory movements of sleeping subjects
Hernandez, L., Waag, B., Hsiao, H., & Neelon, V. J. (1995) · Physiological Measurement · doi:10.1088/0967-3334/16/3/003 · Cited by 31
Three-dimensional ballistocardiographic responses to changes of posture
Soames, R. W., & Atha, J. (1982) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/3/3/001 · Cited by 23
Research works printed but not linked: 2
- Jacobs J L Embree P Glei M Christensen S Sullivan P K, 2004, Proc. 26th Annu. Int. Conf. of IEEE EMBS, 2223
- Ogata M, 1978, System Dynamics
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“[40], and more recently the following implementations: Pressure sensor in the air mattress [41] or in pad [42], film-type force sensors [43] or load cells in the legs of bed [44], microbend fiber optic BCG sensor [45]–[47], EMFi sensors [48], piezoelectric film sensors [49] or polyvinylidene fluoride (PVDF) sensors [5…”
BackgroundSelf-citationThe future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
ECG Recording on a Bed During Sleep Without Direct Skin-Contact
Lim, Y. G., Kim, K. K., & Park, K. S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889194 · Cited by 237
Self-citationBallistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 231
“[57, 58] recommended to use a balancing tube between two air cells to improve the effectiveness of posture changes during data collection.”
MethodAdaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
Brüser, C., Stadlthanner, K., de Waele, S., & Leonhardt, S. K. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2128337 · Cited by 222
Mack, D. C., Patrie, J. T., Suratt, P. M., Felder, R. A., & Alwan, M. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2007194 · Cited by 196
Theory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography
Pinheiro, E., Postolache, O. A., & Girão, P. S. (2010) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701004010201 · Cited by 176
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Brüser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. K. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“variations in air cushions [29], air mattresses [30], or water-”
BackgroundA Flexible Capacitive Pressure Sensor for Wearable Respiration Monitoring System
Park, S. W., Das, P. S., Chhetry, A., & Park, J. Y. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2749233 · Cited by 139
“The sensor integrated into a waist belt along with a capacitive to voltage converter detects the real-time respiration signal [9], [10], [13].”
Automatic Detection of Atrial Fibrillation in Cardiac Vibration Signals
Brüser, C., Diesel, J., Zink, M. D., Winter, S., SCHAUERTE, P. N., & Leonhardt, S. K. (2012) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/titb.2012.2225067 · Cited by 126
Unobtrusive online monitoring of sleep at home
Paalasmaa, J., Waris, M., Toivonen, H. T. T., Leppakorpi, L., & Partinen, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346791 · Cited by 98
Nonconstrained Sleep Monitoring System and Algorithms Using Air-Mattress With Balancing Tube Method
Shin, J. H., Chee, Y. J., Jeong, D., & Park, K. S. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2034011 · Cited by 96
“In order to increase the sensitivity of the sensor, the differential measurement technique was applied [13].”
MethodSelf-citationKortelainen, J. M., & Virkkala, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353894 · Cited by 90
Automatic ballistocardiogram (BCG) beat detection using a template matching approach
Shin, J., Choi, B. H., Lim, Y. G., Jeong, D. U., & Park, K. S. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649363 · Cited by 90
“The analyzed systems were Chee et al (2005)[7] method using balancing tube and air-mattress for unconstrained measurement system, loadcell type BCG measurement system and EMFi-film measurement system were chosen.”
MethodSelf-citationBu, N., Ueno, N., & Fukuda, O. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352551 · Cited by 87
“Alternatively, attempts have been made to measure pressure fluctuation induced by respiration and heartbeat during sleep, using air mattresses [4], [5], an under-pillow sensor [6], and pressure sensors [7], [8].”
BackgroundMethodMonitoring physiological signals using nonintrusive sensors installed in daily life equipment
Lim, Y. G., Hong, K. H., Kim, K. K., Shin, J. H., Lee, S. M., Chung, G. S., Baek, H. J., Jeong, D., & Park, K. S. (2011) · Biomedical Engineering Letters · doi:10.1007/s13534-011-0012-0 · Cited by 81
Self-citationNoninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974313 · Cited by 71
“Furthermore, the sensors based on polyvinylidene fluoride (PVDF) piezopolymer film [5], static charge-sensitive-bed (SCSB) [6], ECG [7], Doppler radar [8], acoustic sensor [9], air mattress [10] and liquid pressure mattress [11] have been adopted to simultaneous measure respiration rate and heart rate.”
MethodImprovement of Force-Sensor-Based Heart Rate Estimation Using Multichannel Data Fusion
Brüser, C., Kortelainen, J. M., Winter, S., Tenhunen, M. L., Pärkkä, J., & Leonhardt, S. K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2311582 · Cited by 72
Unobtrusive Sleep Monitoring Using Cardiac, Breathing and Movements Activities: An Exhaustive Review
Matar, G., Lina, J., Carrier, J., & Kaddoum, G. (2018) · IEEE Access · doi:10.1109/access.2018.2865487 · Cited by 74
“This method has been validated on synthetic data and then clinically only in supine sleeping posture [184].”
MethodHB-Phone: A Bed-Mounted Geophone-Based Heartbeat Monitoring System
Jia, Z., Alaziz, M., Chi, X., Howard, R. E., Zhang, Y., Zhang, P., Trappe, W. K., Sivasubramaniam, A., & An, N. (2016) · ACM/IEEE International Conference on Information Processing in Sensor Networks (IPSN) · doi:10.1109/ipsn.2016.7460676 · Cited by 66
“, those in [30], [14], [28], [26], [19], [18], [17], or piezoelectric sensor [13], [29], [23]; force sensors, e.”
BackgroundMethodInfluentialMonitoring pulse and respiration with a non-invasive hydraulic bed sensor
Heise, D., & Skubic, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627219 · Cited by 65
“The use of ballistocardiography for passive sensing of pulse and respiration has become more popular recently, as evidenced by [4-8].”
BackgroundUnconstrained cardiorespiratory and body movement monitoring system for home care
Niizeki, K., Nishidate, I., Uchida, K., & Kuwahara, M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02430948 · Cited by 65
FBG-based smart bed system for healthcare applications
Hao, J., Jayachandran, M., Kng, P. L., Foo, S. F., Wai, A. A. P., & Cai, Z. (2010) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0066-0 · Cited by 61
“For techniques using fluid technology (such as water, air), there are related works [5,6] on respiratory and heart rate monitoring.”
BackgroundHeart rate detection from an electronic weighing scale
González-Landaeta, R., Casas, Ó., & Pallas-Areny, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/8/009 · Cited by 59
Smart Mattress Based on Multipoint Fiber Bragg Gratings for Respiratory Rate Monitoring
Tommasi, F. D., Presti, D. L., Caponero, M., Carassiti, M., Schena, E., & Massaroni, C. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3232615 · Cited by 57
“monitoring gathered the attention of several research groups and companies [19], [20], [21], [22], [23], [24], [25], [26], [27], [28], [29], [30], [31], [32], [33], [34], [35], [36], [37], [38], [39], [40], [41], [42], [43], [44], [45], [46].”
BackgroundShin, J. H., Hwang, S. H., Chang, M. H., & Park, K. S. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/015 · Cited by 58
Self-citationLiu, J. J., Huang, M.-C., Xu, W., Zhang, X., Stevens, L. J., Alshurafa, N. I., & Sarrafzadeh, M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2344679 · Cited by 55
“X. Zhang is with the Computer Science and Engineering, University of Washington, Seattle, WA 98195 USA (e-mail: xiaoyiz@cs.washington.edu).”
MethodMulti-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed
Brüser, C., Kerekes, A., Winter, S., & Leonhardt, S. K. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347126 · Cited by 44
“com (PVDF) foils placed on top or beneath the mattress [1], [2], pneumatic mattresses [3], [4], hydraulic under-pillow sensors [5], infra-red sensor integrated into spring-coil mattresses [6], strain gauges under bed posts [7] or on the bed frame [8], as well as ultrasound sensors placed in a cavity beneath the mattre…”
MethodFBG-Based Mattress for Heart Rate Monitoring in Different Breathing Conditions
Tommasi, F. D., Massaroni, C., Caponero, M., Carassiti, M., Schena, E., & Presti, D. L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3275323 · Cited by 44
“testify [16], [18], [19], [20], [21], [22], [23], [24].”
Home geriatric physiological measurements
TAMURA, T. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/r47 · Cited by 38
“…et al 2005, Park et al 2008), a polyvinylidene fluoride piezopolymer sensor (Niizeki et al 2005), a pneumatic sensor (Watanabe and Watanabe 2004, Chee et al 2005), an optical fibre (Nishyama et al 2011) phonocardiographic sensor (Tanaka et al 2002) or a static-charge-sensitive bed (Alihanka et…”
BackgroundGhodratigohar, M., Ghanadian, H., & Osman, H. A. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2946132 · Cited by 38
“2946132 monitoring respiration [6], the RR signal can be distorted by non-respiratory-induced movements [6].”
BackgroundNoninvasive Measurement of Heart Rate and Respiratory Rate for Perioperative Infants
Zhang, Y., Chen, Z., & Hee, H. I. (2018) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2883413 · Cited by 37
“More importantly, those new sensors enable automated and simultaneous measurement of both HR and RR, including Emfit sensor [1], air mattress sensor [2], liquid pressure sensor [3], ECG sensor [4], Doppler radar sensor [5], acoustic sensor”
Aubert, X. L., & Brauers, A. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650273 · Cited by 37
Ahmadzadeh, S., Luo, J., & Wiffen, R. (2020) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3033930 · Cited by 39
“heart beat and respiration Air Matress sensor system Matres system allows Measurement of the respiration and heart beat activity without use of a sensor on the subjects body [159] 2005”
MethodAlbukhari, A., Lima, F. G. D. C., & Mescheder, U. M. (2019) · Sensors · doi:10.3390/s19061451 · Cited by 36
“At the same time, the widespread utilization of BCG in sleep monitoring applications, made embedding BCG sensors in beds quite prevalent [14,25–28], even in air mattresses [29] and pillows [30].”
BackgroundVehkaoja, A. T., Rajala, S., Kumpulainen, P. S., & Lekkala, J. O. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.807523 · Cited by 35
“[14] developed an air mattress system for the unconstrained measurement of respiration and heartbeat movement.”
BackgroundA respiratory latent variable model for mechanically measured heartbeats
Paalasmaa, J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/10/003 · Cited by 31
Unconstrained monitoring of long-term heart and breath rates during sleep
Chen, W., Zhu, X., Nemoto, T., Kitamura, K., Sugitani, K., & Wei, D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/2/n01 · Cited by 31
Clinical assessment applications of ambulatory biosensors.
Haynes, S. N., & Yoshioka, D. T. (2007) · Psychological Assessment · doi:10.1037/1040-3590.19.1.44 · Cited by 29
Heart Rate Detection from an Electronic Weighing Scale
González-Landaeta, R., Casas, Ó., & Pallas-Areny, R. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353791 · Cited by 28
Wang, Y., You, M., Zhang, Y., Wu, S., Zhang, Y., Yang, H., Zheng, T., Chen, X., Chen, Z., Xie, X., et al. (2022) · Biomedical Optics Express · doi:10.1364/boe.450258 · Cited by 26
“Among all kinds of new vital signs sensors, like acoustic sensor [1], ECG sensor [2], air mattress sensor [3], electrical sensors [4–7], and optical sensors [8–29], that operate in a noninvasive way are widely studied because they are easy to use and without physical constraint to patients.”
BackgroundQuantifying respiratory variation with force sensor measurements
Paalasmaa, J., Leppakorpi, L., & Partinen, M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090773 · Cited by 25
“Recently, various sensors and analysis methods have been developed for the long-term measurement of sleep, including a bed post sensor [1], a pillow sensor [2] as well as different kinds of mattress sensors [3], [4].”
BackgroundA Survey of Approaches to Unobtrusive Sensing of Humans
Fernandes, J. M., Silva, J. S., Rodrigues, A., & Boavida, F. (2022) · ACM Computing Surveys · doi:10.1145/3491208 · Cited by 29
“Image adapted from [40]. bed or altered bed parts to monitor humans’ heart rate, such as the works of [17, 87].”
BackgroundStudy on Ballistocardiogram Acquisition in a Moving Wheelchair with Embedded Sensors
Pinheiro, E., Postolache, O. A., & Girão, P. S. (2012) · Metrology and Measurement Systems · doi:10.2478/v10178-012-0065-0 · Cited by 23
Carek, A. M., & Holz, C. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264906 · Cited by 22
“Previous studies used pressure sensors in an air mattress [12], load cells in the legs of a bed [13], and piezoelectric film sensors in a mattress pad [42].”
MethodBed-Based Health Monitoring Using Pressure Sensitive Technology: A Review
Cohen-McFarlane, M., Bennett, S. L., Wallace, B., Goubran, R. A., & Knoefel, F. D. (2021) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2021.9400964 · Cited by 21
“PSM have been used to monitor breathing rate over the course of the night in [12], [34]–[36].”
BackgroundMethodWei, C., Lin, Y.-C., Chen, T.-A., Lin, R.-Y., & Liu, T.-H. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2315532 · Cited by 19
“To make respiration monitoring available for homecare patients, one solution is to embed sensors in a bed and sense respiration indirectly by detecting body movements [7]–[9].”
BackgroundXu, W. L., Yu, C., Dong, B., Wang, Y., & Zhao, W. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3128601 · Cited by 18
Vehkaoja, A. T., Kontunen, A., & Lekkala, J. O. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319366 · Cited by 18
“Special mattresses with integrated sensors have also been developed [13], [14], [15].”
BackgroundDetection of Snores Using Source Separation on an Emfit Signal
Perez-Macias, J. M., Tenhunen, M. L., Värri, A. O., Himanen, S., & Viik, J. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2757530 · Cited by 18
“bed (SCSB), the sheet-type SD-101, and the balancing tube air-mattress (AMBT), have been used for multiple purposes, such as (1) breathing rate (BR) and heart rate (HR) monitoring [24]–[29], (2) SDB diagnosis [30]–[40], (3) epilepsy monitoring, (4) periodic leg movements and restless legs syndrome assessment [41]–[43].”
MethodNon-contact Home Health Monitoring Based on Low-Cost High-Performance Accelerometers
Feng, X., Dong, M., Levy, P. D., & Xu, Y. P. (2017) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase.2017.119 · Cited by 17
“piezoelectric film sensors under bed sheets [34, 35], fiber optic force sensors within chairs and beds [36-38], pneumatic pressure sensors in air mattresses and cushions [39-41], force sensors installed under the bed posts [42-44], and strain gauges mounted to the slats of a hospital bed frame [45].”
BackgroundHigh Fidelity MZI-BCG Sensor With Homodyne Demodulation for Unobtrusive HR and BP Monitoring
Yang, F., Xu, W. L., Lyu, W., Tan, F., Yu, C., & Dong, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3158070 · Cited by 16
Kurihara, Y., Watanabe, K., & Tanaka, H. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2067221 · Cited by 16
Spectral analysis of snoring events from an Emfit mattress
Perez-Macias, J. M., Viik, J., Värri, A. O., Himanen, S., & Tenhunen, M. L. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/12/2130 · Cited by 15
Park, S., & Shin, H. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2695565 · Cited by 15
“than PVDF [11], [12] or air mattress [23] sensors.”
BackgroundZhu, X., Zhou, X., Chen, W., Kitamura, K., & Nemoto, T. (2014) · IEEE International Conference on Ubiquitous Intelligence and Computing, Autonomic and Trusted Computing, and Scalable Computing and Communications (UIC-ATC-ScalCom) · doi:10.1109/uic-atc-scalcom.2014.138 · Cited by 14
Chen, X., Zhang, H., Li, Z., Liu, S., & Zhou, Y. (2024) · JMIR mhealth and uhealth · doi:10.2196/56226 · Cited by 13
“In recent years, the rapid development of sensing technology has facilitated the employment of wearable devices for vital signs monitoring [11].”
BackgroundNew Paths in Respiratory Sleep Medicine
Penzel, T., Dietz-Terjung, S., Woehrle, H., & Schöbel, C. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.006 · Cited by 13
Zaid, M., Sala, L., Ivey, J. R., Tharp, D. L., Mueller, C. M., Thorne, P. K., Kelly, S. C., Silva, K. A. S., Amin, A. R., Ruiz‐Lozano, P., et al. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.788264 · Cited by 13
An intelligent elderly healthcare monitoring system using fiber‐based sensors
Hao, J., Jayachandran, M., Ni, N., Phua, J. E., Liew, H., Wai, A. A. P., Biswas, J., Foo, S. F., Low, J. A., & Yap, L. K. P. (2010) · Journal of the Chinese Institute of Engineers · doi:10.1080/02533839.2010.9671654 · Cited by 13
“There are some other related works using wireless technology (Xu et al., 2007a; Pan, 2008b; Kortelainen and Virkkala, 2007c; Jeung et al., 2004d; Jeung et al., 2005e) or fluid technology (such as water, air) (Zhu et al., 2005a; Chee et al., 2005b) on respiration and heart rate monitoring.”
BackgroundJung, D. W., Hwang, S. H., Lee, Y. J., Jeong, D., & Park, K. S. (2016) · Respiration · doi:10.1159/000448120 · Cited by 13
Self-citationMotoi, K., Yamakoshi, Y., Yamakoshi, T., Sakai, H., Tanaka, N., & Yamakoshi, K.-I. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0304-9 · Cited by 13
Li, W., Sun, C., Chen, C., & Chen, W. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409881 · Cited by 13
“However, these systems required for special beds due to their complex sensing principles which greatly limited its applicability [1] [2] [3].”
BackgroundAccurate Spirometry with Integrated Barometric Sensors in Face-Worn Garments
Zhou, B., Costa, A. B., & Lukowicz, P. (2020) · Sensors · doi:10.3390/s20154234 · Cited by 12
Automatic Concealed Heart Rate Detection from the BCG in Seated Position
Luna-Lozano, P. S., & Pallas, R. (2015) · IEEE Latin America Transactions · doi:10.1109/tla.2015.7069078 · Cited by 12
“Las medidas en personas acostadas [7], [8] son indicadas cuando hay algún riesgo de muerte súbita durante el sueño o para monitorización continua en personas hospitalizadas.”
BackgroundNonintrusive Monitoring and Detection of Sitting and Lying Persons: A Technological Review
Salice, F., de Vellis, M., Barbieri, A., Masciadri, A., & Comai, S. (2024) · IEEE Access · doi:10.1109/access.2024.3508836 · Cited by 11
Chen, Z., Teo, J. T., Ng, S. H., Yang, X., Zhou, B., Zhang, Y., Loo, H. P., Zhang, H., & Thong, M. K. T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944841 · Cited by 11
A New Sensory Device and Optimal Position for Monitoring HR/RR during Sleep
Chen, W., Zhu, X., & Nemoto, T. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03885-3_36 · Cited by 9
“[3] and Shin et al.”
Motoi, K., Ogawa, M., Ueno, H., Fukunaga, S., Yuji, T., Higashi, Y., Tanaka, S., Fujimoto, T., Asanoi, H., & Yamakoshi, K.-I. (2010) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2010.5687774 · Cited by 8
Sleep and Sleep Assessment Technologies
Koenig, S. M., Mack, D. C., & Alwan, M. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-233-5_5 · Cited by 8
“Fig. 5.20 Korean Air Mattress [ 91 ] (Image Credit: Used with permission from IOP Publishing Ltd.) 112 S. M. Koenig et al.”
BackgroundMethodInfluentialVital Sign Monitoring for Cancer Patients Based on Dual-Path Sensor and Divided-Frequency-CNN Model
Lin, B., Jia, C., Yang, H., Zhang, Y., Xie, X., Chen, Z., & Zhang, X. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3368061 · Cited by 6
Smartphone-based and non-invasive sleep stage identification system with piezo-capacitive sensors
Pérez-Ávila, A. J., Herrera, N. R., Martínez-Olmos, A., Carvajal, M. A., Capitán-Vallvey, L. F., López-Ruiz, N., & Palma, A. J. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115659 · Cited by 6
“In recent years, several researchers have advocated for the development of simpler and user-friendly equipment for sleep data recording [11 – 16].”
Tommasi, F. D., D’Antoni, F., Presti, D. L., Silvestri, S., Fortino, G., Schena, E., Merone, M., & Massaroni, C. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3559724 · Cited by 6
“The application of a single airflow sensor in an air pocket single sensor strategically placed into the mattress or placed between the mattress and bedframehasbeeninvestigatedin[39],[40]tomonitorbreathing andcardiacactivities.”
Casanella, R., Khosrow-Khavar, F., Schmidt, S. E., Zanetti, J. M., & Tavakolian, K. (2019) · Series in bioengineering · doi:10.1007/978-981-10-5092-3_3 · Cited by 6
Nonintrusive measurement of biological signals for ubiquitous healthcare
Park, K. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334000 · Cited by 5
“To solve the saturation problem in air mattress sensor system, balancing tube was used [ 6 ].”
MethodSelf-citationNon-intrusive respiratory monitoring system using Fiber Bragg Grating sensor
Fook, V. F. S., Kng, P. L., Zhong, E., Jayachandran, M., Wai, A. A. P., Biswas, J., Si, L. W., & Yap, P. L. K. (2008) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/health.2008.4600128 · Cited by 5
“The sensors must be sensitive enough to capture the correct respiratory rate while not changing the behavior of the patients or elderly.”
BackgroundPark, K. S., & Yoon, H. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_5 · Cited by 5
Self-citationXu, A., Chen, E., & Chen, J. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3144961 · Cited by 4
Body Area Network based Health Monitoring of Critical Patients: a Brief Review
Laddi, A. (2012) · International Journal of Instrumentation and Control Systems · doi:10.5121/ijics.2012.2305 · Cited by 4
Immanuel, S. A., Kohler, M. J., Pamula, Y., Kabir, M., Saint, D. A., & Baumert, M. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609928 · Cited by 3
Unobtrusive Non-Contact Detection of Arrhythmias using a “Smart” Bed
Brueser, C. (2011) · Acta Polytechnica · doi:10.14311/1426 · Cited by 3
“Using a variety of different sensors, including but not limited to strain gauges [3, 4], PVDF and EMFi sensors [5, 6], accelerometers [7], hydraulic [8] and pneumatic sensors [9, 10] as well as optical devices [11], BCG systems have been integrated into objects of daily life, such as beds [4–12], chairs [13] and even…”
BackgroundKutílek, P., Zizka, A., & Vítečková, S. (2012) · International Conference on Telecommunications and Signal Processing (TSP) · doi:10.1109/tsp.2012.6256341 · Cited by 3
Apnea Detection with Microbend Fiber-Optic Sensor
Liu, L., Ye, T., Guo, X., Kong, R., Bo, L., & Wang, G. (2017) · Lecture notes in electrical engineering · doi:10.1007/978-981-10-6499-9_21 · Cited by 3
A Machine Learning-Based Non-Contact Respiratory Rate Monitoring Method Using an RGB Camera
Ghodratigohar, M. (2019) · uO Research (University of Ottawa) · doi:10.20381/ruor-23592 · Cited by 3
“Although some contactless methods, namely air mattress sensors, are capable of monitoring respiration [4], the RR signal can be distorted by non-respiratory-induced movements [4].”
BackgroundLin, G., Jia, C., Wang, L., Chen, Z., Yang, H., Lin, X., Liu, T., Chen, W., & Ni, S. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3592200 · Cited by 2
Brüser, C., Strutz, N., Winter, S., Leonhardt, S. K., & Walter, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2340703 · Cited by 2
Kutílek, P., Hozman, J., & Smrčka, P. (2012) · Cited by 2
Tsai, C.-C., Lu, H.-K., Chu, L.-P., Ting, C.-C., Hsieh, K.-C., & Lai, C.-L. (2018) · International Symposium on Computer, Consumer and Control · doi:10.1109/is3c.2018.00031 · Cited by 2
“[5] used an air cushion with an air flow sensor to detect the BCG signal.”
MethodZhang, X., Tang, J., Sharp, G. C., Xiao, L., Xu, S., & Lu, H. (2020) · British Journal of Radiology · doi:10.1259/bjr.20190303 · Cited by 2
Clinical Applications of Behavioral Assessment
Haynes, S. N., Yoshioka, D. T., Kloezeman, K. C., & Bello, I. (2012) · Oxford University Press eBooks · doi:10.1093/oxfordhb/9780195366877.013.0013 · Cited by 2
Heart pulse demodulation from Emfit mattress sensor using spectral and source separation techniques.
Perez-Macias, J. M., Värri, A. O., Himanen, S., Tenhunen, M. L., & Viik, J. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.304 · Cited by 2
Pneumatic frequency selection filter in the prior stage of the air pressure transducer
Chee, Y., & Park, K. (2008) · Measurement · doi:10.1016/j.measurement.2008.08.002 · Cited by 1
Self-citationResonant plethysmography for unconstrained monitoring of respiration
Lee, G., & Park, K. S. (2008) · Electronics Letters · doi:10.1049/el:20083125 · Cited by 1
Self-citationBaHammam, A. S., Pandi-Perumal, S. R., & Hunasikatti, M. (2023) · Progress in Sleep Research · doi:10.1007/978-981-99-7901-1_10 · Cited by 1
Noh, Y.-H., & Jeong, D. (2009) · International Conference on Information Sciences and Interaction Sciences · doi:10.1145/1655925.1656019 · Cited by 1
“This make the research of ballistic measurement system is accomplished [5], [6].”
BackgroundA Preliminary Study for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair
Kim, K. K., Chee, Y., Park, J., Kim, J., Lim, Y. K., & Park, K. S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1617253 · Cited by 1
“The PAT can be measured from the electrically non-contact ECG [3], [4] and the pressure pulse of femoral artery with the air cushion using the balancing tubes [5] on a chair.”
MethodSelf-citationMalakuti, K. (2008) · UVic’s Research and Learning Repository (University of Victoria) · Cited by 1
Nanowire and Fiber Composite Electromechanical Sensor
Chen, Q. (2012) · D-Scholarship@Pitt (University of Pittsburgh)
Waters, J. (2011) · University of New Hampshire Scholars Repository (University of New Hampshire at Manchester)
Metadata
- Authors
- Chee, Y., Han, J., Youn, J., & Park, K.
- Affiliations
- Seoul National University (KR)
- ORCID
- Park, Kwangsuk
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-04-11
- Volume
- 26
- Issue
- 4
- Pages
- 413-422
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2056344526
- Semantic Scholar
- c5e2afd42dd3b887f73cfd6e7596e5f6829ee799
- Cited by
- 111
- References
- 11
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 10 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 7 · 2017: 7 · 2016: 4 · 2015: 3 · 2014: 8 · 2013: 3 · 2012: 10
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Korea Science and Engineering Foundation
- Arizona Biomedical Research Commission
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- respiratory monitoring, cardiorespiratory signals, differential measurement, mathematical model, sleep analysis
- MeSH terms
- Air, Beds, Computer Simulation, Diagnosis, Computer-Assisted, Equipment Design, Heart Rate, Humans, Models, Biological, Monitoring, Physiologic, Respiration, Rheology, Transducers, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review