The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter
Open accessAbstract
Physiological signals such as the electrocardiogram (ECG) and arterial blood pressure (ABP) in the intensive care unit (ICU) are often severely corrupted by noise, artifact and missing data, which lead to large errors in the estimation of the heart rate (HR) and ABP. A robust HR estimation method is described that compensates for these problems. The method is based upon the concept of fusing multiple signal quality indices (SQIs) and HR estimates derived from multiple electrocardiogram (ECG) leads and an invasive ABP waveform recorded from ICU patients. Physiological SQIs were obtained by analyzing the statistical characteristics of each waveform and their relationships to each other. HR estimates from the ECG and ABP are tracked with separate Kalman filters, using a modified update sequence based upon the individual SQIs. Data fusion of each HR estimate was then performed by weighting each estimate by the Kalman filters' SQI-modified innovations. This method was evaluated on over 6000 h of simultaneously acquired ECG and ABP from a 437 patient subset of ICU data by adding real ECG and realistic artificial ABP noise. The method provides an accurate HR estimate even in the presence of high levels of persistent noise and artifact, and during episodes of extreme bradycardia and tachycardia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationA comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Cited by
A Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
Ventricular Fibrillation and Tachycardia Classification Using a Machine Learning Approach
Li, Q., Rajagopalan, C., & Clifford, G. D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2275000 · Cited by 274
Self-citationSatija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Machine learning improves risk stratification after acute coronary syndrome
Myers, P. D., Scirica, B. M., & Stultz, C. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-12951-x · Cited by 75
“The signal was then normalized by the mean R-wave amplitude and the Physionet Signal Quality Index 40 was used to remove noisy signal segments.”
Chong, J. W., Dao, D. K., Salehizadeh, S. M. A., McManus, D. D., Darling, C. E., Chon, K. H., & Mendelson, Y. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1080-y · Cited by 79
Metadata
- Authors
- Li, Q., Mark, R. G., & Clifford, G. D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-12-10
- Volume
- 29
- Issue
- 1
- Pages
- 15-32
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2021044602
- Cited by
- 426
- References
- 3
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter. https://app.cochat.ai/papers/10.1088/0967-3334/29/1/002
- The paper
- Li, Q., Mark, R. G., & Clifford, G. D. (2008). Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter. Physiological Measurement. https://doi.org/10.1088/0967-3334/29/1/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.