CoChat

A simulation model of glucose regulation in the critically ill

Open access
Hovorka, Roman, Chassin, Ludovic J, Ellmerer, Martin, Plank, Johannes, Wilinska, Malgorzata E · 2008 · Physiological Measurement
Cited by 101

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Focused research is underway to improve the delivery of tight glycaemic control at the intensive care unit. A major component is the development of safe, efficacious and effective insulin titration algorithms, which are normally evaluated in time-consuming resource-demanding clinical studies. Simulation studies with virtual critically ill patients can substantially accelerate the development process. For this purpose, we created a model of glucoregulation in the critically ill. The model includes five submodels: a submodel of endogenous insulin secretion, a submodel of insulin kinetics, a submodel of enteral glucose absorption, a submodel of insulin action and a submodel of glucose kinetics. Model parameters are estimated utilizing prior knowledge and data collected routinely at the intensive care unit to represent the high intersubject and temporal variation in insulin needs in the critically ill. Bayesian estimation combined with the regularization method is used to estimate (i) time-invariant model parameters and (ii) a time-varying parameter, the basal insulin concentration, which represents the temporal variation in insulin sensitivity. We propose a validation process to validate virtual patients developed for the purpose of testing glucose controllers. The parameter estimation and the validation are exemplified using data collected in six critically ill patients treated at a medical intensive care unit. In conclusion, a novel glucoregulatory model has been developed to create a virtual population of critically ill facilitating in silico testing of glucose controllers at the intensive care unit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/29/8/008

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 101

Metadata

Authors
Hovorka, R., Chassin, L. J., Ellmerer, M., Plank, J., & Wilinska, M. E.
Venue
Physiological Measurement
Published
2008-07-18
Volume
29
Issue
8
Pages
959-978
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2069921929
Cited by
101
References
9
FWCI
4.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simulation model of glucose regulation in the critically ill. https://app.cochat.ai/papers/10.1088/0967-3334/29/8/008
The paper
Hovorka, R., Chassin, L. J., Ellmerer, M., Plank, J., & Wilinska, M. E. (2008). A simulation model of glucose regulation in the critically ill. Physiological Measurement. https://doi.org/10.1088/0967-3334/29/8/008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.