The validity of wireless iButtons® and thermistors for human skin temperature measurement

Open access
Smith, A D Harper, Crabtree, D R, Bilzon, J L J, Walsh, N P · 2010 · Physiological Measurement
Cited by 153

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons and thermistors monitored temperature in a controlled water bath (range: 10-40 degrees C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 degrees C, 20 degrees C and 30 degrees C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows. Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 degrees C for iButtons and +0.045 degrees C for thermistors. Upon calibration correction the mean bias for iButtons and thermistors was not significantly different from zero bias. Interestingly, a typical error of the estimate of iButtons (0.043 degrees C) was 1.5 times less than that of thermistors (0.062 degrees C), demonstrating iButtons' lower random error. Investigation 2: the offset between iButton and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons and thermistors during resting trials ranged from 0.261 degrees C to 1.356 degrees C. Mean temperature differences between iButtons and thermistors during exercise were 0.989 degrees C (ambient temperature = 10 degrees C), 0.415 degrees C (ambient temperature = 20 degrees C) and 0.318 degrees C (ambient temperature = 30 degrees C). Observed error estimates were within the acceptable limits for the skin temperature method comparison, with typical errors <0.3 degrees C, correlation coefficients >0.9 and CV <1% under all conditions. These findings indicate that wireless iButtons provide a valid alternative for human skin temperature measurement during laboratory and field investigations particularly when skin temperature measurement using other currently available methods may prove problematic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/31/1/007

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 153

Metadata

Authors
Smith, A. D. H., Crabtree, D. R., Bilzon, J. L. J., & Walsh, N. P.
Venue
Physiological Measurement
Published
2009-11-26
Volume
31
Issue
1
Pages
95-114
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2143743535
Cited by
153
References
7
FWCI
2.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The validity of wireless iButtons® and thermistors for human skin temperature measurement. https://app.cochat.ai/papers/10.1088/0967-3334/31/1/007
The paper
Smith, A. D. H., Crabtree, D. R., Bilzon, J. L. J., & Walsh, N. P. (2010). The validity of wireless iButtons® and thermistors for human skin temperature measurement. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/1/007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.