The validity of wireless iButtons® and thermistors for human skin temperature measurement
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons and thermistors monitored temperature in a controlled water bath (range: 10-40 degrees C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 degrees C, 20 degrees C and 30 degrees C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows. Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 degrees C for iButtons and +0.045 degrees C for thermistors. Upon calibration correction the mean bias for iButtons and thermistors was not significantly different from zero bias. Interestingly, a typical error of the estimate of iButtons (0.043 degrees C) was 1.5 times less than that of thermistors (0.062 degrees C), demonstrating iButtons' lower random error. Investigation 2: the offset between iButton and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons and thermistors during resting trials ranged from 0.261 degrees C to 1.356 degrees C. Mean temperature differences between iButtons and thermistors during exercise were 0.989 degrees C (ambient temperature = 10 degrees C), 0.415 degrees C (ambient temperature = 20 degrees C) and 0.318 degrees C (ambient temperature = 30 degrees C). Observed error estimates were within the acceptable limits for the skin temperature method comparison, with typical errors <0.3 degrees C, correlation coefficients >0.9 and CV <1% under all conditions. These findings indicate that wireless iButtons provide a valid alternative for human skin temperature measurement during laboratory and field investigations particularly when skin temperature measurement using other currently available methods may prove problematic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Progressive Statistics for Studies in Sports Medicine and Exercise Science
HOPKINS, W. G., MARSHALL, S. W., BATTERHAM, A. M., & HANIN, J. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818cb278 · Cited by 9,128
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Evaluation of wireless determination of skin temperature using iButtons
VANMARKENLICHTENBELT, W., DAANEN, H., WOUTERS, L., FRONCZEK, R., RAYMANN, R., SEVERENS, N., & VANSOMEREN, E. (2006) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.04.026 · Cited by 392
Altered Skin-Temperature Regulation in Narcolepsy Relates to Sleep Propensity
Fronczek, R., Overeem, S., Lammers, G. J., van Dijk, J. G., & van Someren, E. J. W. (2006) · Sleep · doi:10.1093/sleep/29.11.1444 · Cited by 92 · cited 1×
“The iButton R© devices were originally designed to monitor temperature-sensitive consignments during transport and have been utilized in relatively few scientific studies (Areas et al 2006, Davidson et al 2003, Fronczek et al 2006, Hubbart et al 2005, Johnson et al 2005, Lichtenbelt et al 2006).”
Method
Cited by
Sawka, M. N., Leon, L. R., Montain, S. J., & Sonna, L. A. (2011) · Comprehensive Physiology · doi:10.1002/cphy.c100082 · Cited by 470
Leon, L. R., & Bouchama, A. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140017 · Cited by 403
Personal thermal comfort models with wearable sensors
Liu, S., Schiavon, S., Das, H. P., Jin, M., & Spanos, C. J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106281 · Cited by 306
Thermal pleasure in built environments: alliesthesia in different thermoregulatory zones
Parkinson, T., de Dear, R., & Candido, C. (2016) · Building Research & Information · doi:10.1080/09613218.2015.1059653 · Cited by 126
Capella, M. D. M., Martinez-Nicolas, A., & Adan, A. (2018) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2018.00373 · Cited by 17
Metadata
- Authors
- Smith, A. D. H., Crabtree, D. R., Bilzon, J. L. J., & Walsh, N. P.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2009-11-26
- Volume
- 31
- Issue
- 1
- Pages
- 95-114
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2143743535
- Cited by
- 153
- References
- 7
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The validity of wireless iButtons® and thermistors for human skin temperature measurement. https://app.cochat.ai/papers/10.1088/0967-3334/31/1/007
- The paper
- Smith, A. D. H., Crabtree, D. R., Bilzon, J. L. J., & Walsh, N. P. (2010). The validity of wireless iButtons® and thermistors for human skin temperature measurement. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/1/007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.