The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Segmentation of heart sound recordings by a duration-dependent hidden Markov model
Abstract
Digital stethoscopes offer new opportunities for computerized analysis of heart sounds. Segmentation of heart sound recordings into periods related to the first and second heart sound (S1 and S2) is fundamental in the analysis process. However, segmentation of heart sounds recorded with handheld stethoscopes in clinical environments is often complicated by background noise. A duration-dependent hidden Markov model (DHMM) is proposed for robust segmentation of heart sounds. The DHMM identifies the most likely sequence of physiological heart sounds, based on duration of the events, the amplitude of the signal envelope and a predefined model structure. The DHMM model was developed and tested with heart sounds recorded bedside with a commercially available handheld stethoscope from a population of patients referred for coronary arterioangiography. The DHMM identified 890 S1 and S2 sounds out of 901 which corresponds to 98.8% (CI: 97.8-99.3%) sensitivity in 73 test patients and 13 misplaced sounds out of 903 identified sounds which corresponds to 98.6% (CI: 97.6-99.1%) positive predictivity. These results indicate that the DHMM is an appropriate model of the heart cycle and suitable for segmentation of clinically recorded heart sounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743
Cited by
An open access database for the evaluation of heart sound algorithms
Liu, C., Springer, D., Li, Q., Moody, B., Juan, R. A., Chorro, F. J., Castells, F., Roig, J. M., Silva, I., Johnson, A. E. W., et al. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/12/2181 · Cited by 820
Self-citationA systematic survey of computer-aided diagnosis in medicine: Past and present developments
Yanase, J., & Triantaphyllou, E. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.112821 · Cited by 303
In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring
Martin, A., & Voix, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2720463 · Cited by 112
Metadata
- Authors
- Schmidt, S. E., Holst-Hansen, C., Graff, C., Toft, E., & Struijk, J. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-03-05
- Volume
- 31
- Issue
- 4
- Pages
- 513-529
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2020459286
- Cited by
- 297
- References
- 1
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Segmentation of heart sound recordings by a duration-dependent hidden Markov model. https://app.cochat.ai/papers/10.1088/0967-3334/31/4/004
- The paper
- Schmidt, S. E., Holst-Hansen, C., Graff, C., Toft, E., & Struijk, J. J. (2010). Segmentation of heart sound recordings by a duration-dependent hidden Markov model. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/4/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.