The DOI matches its Crossref record; 29 of the 31 references it cites were found in a registry or an index.
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Open accessAbstract
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some other examples are mentioned here: Bayesian network for classifying stress level [26,39] or for predicting patient's state [72], Fuzzy state machine for estimating the health status to provide alerts [68], logistic regression models [42] and association rules [41] to predict stress level and hospitalization of hemodialysis patients, respectively.”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [72]
In the citing paper
“Several approaches have been proposed, including statistical analysis of pulse wave shape [56], assessing the level of perfusion through the perfusion index (the ratio of the amplitude of the pulsatile component of the PPG to its baseline) [56], assessing the similarity of successive pulse wave shapes using template matching [86] or dynamic time warping [87], and deep learning [88].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [87]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Faires, J. D. (1978) · Cited by 6,711
The Levenberg-Marquardt algorithm: Implementation and theory
Morè, J. J. (1978) · Lecture notes in mathematics · doi:10.1007/bfb0067700 · Cited by 5,796
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Exact indexing of dynamic time warping
Keogh, E., & Ratanamahatana, C. A. (2004) · Knowledge and Information Systems · doi:10.1007/s10115-004-0154-9 · Cited by 1,962
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291140 · Cited by 326
Saeed, M., Lieu, C., RABER, G., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166854 · Cited by 273
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Signal processing methods for heart rate variability
Clifford, G. D. (2002) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-noa0mqzyn · Cited by 131
Self-citation
Research works printed but not linked: 14
- Addison P S Watson J N, 2010
- Clifford G D, 2011, Comput. Cardiol., 38, 285
- Graybeal J M Petterson M T, 2004, Proc. 26th Annu. Int. Conf. IEEE EMBS, 5363
- Huang B Kinsner W, 2002, Proc. 2002 IEEE Canadian Conf. on Electrical and Computer Engineering, 1105
- Krishnan R Natarajan B Warren S, 2008, Proc. 17th Int. Conf. on Computer Communications and Networks ICCCN '08, 1
- Krishnan R Natarajan B Warren S, 2008, IEEE Int. Conf. on Acoustics, Speech and Signal Processing, 613
- Lee C M Zhang Y T, 2003, IEEE EMBS Asian-Pacific Conf. on Biomed. Eng., 194
- Lee H W, 2007, Int. J. Control Autom. Syst., 5, 701
- Reddy K A Kumar V J, 2007, Proc. IEEE Instrumentation and Measurement Technology Conf. IMTC, 1
- Relente A R Sison L G, 2002, Proc. 2nd Joint EMBS/BMES Conf., 1769
- Sukanesh R, 2010, Biomed. Softw. Comput. Hum. Sci., 16, 135
- Vullings H J L M Verhaegen M H G Verbruggen H B, 1998, Proc. 20th Annu. Conf. IEEE EMBS, 163
- Yao J Warren S, 2005, IEEE-EMBS 27th Annu. Int. Conf. of the Engineering in Medicine and Biology Society, 3585
- Zong W, 2003, Comput. Cardiol., 30, 259
Cited by
Sorted by citations
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Optimal Signal Quality Index for Photoplethysmogram Signals
Elgendi, M. (2016) · Bioengineering · doi:10.3390/bioengineering3040021 · Cited by 338
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 263
Metadata
- Authors
- Li, Q., & Clifford, G. D.
- Affiliations
- Shandong University (CN)
- University of Oxford (GB)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1491-1501
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1989977532
- Cited by
- 274
- References
- 31
- Citations by year
- 2026: 18 · 2025: 13 · 2024: 17 · 2023: 26 · 2022: 28 · 2021: 25 · 2020: 22 · 2019: 18 · 2018: 25 · 2017: 20 · 2016: 25 · 2015: 15 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, signal quality assessment, dynamic time warping, template matching, multilayer perceptron, arrhythmia detection, intensive care monitoring
- MeSH terms
- Algorithms, Artificial Intelligence, Humans, Quality Control, Time Factors, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review