Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Open accessAbstract
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some other examples are mentioned here: Bayesian network for classifying stress level [26,39] or for predicting patient's state [72], Fuzzy state machine for estimating the health status to provide alerts [68], logistic regression models [42] and association rules [41] to predict stress level and hospitalization of hemodialysis patients, respectively.”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [72]
In the citing paper
“Several approaches have been proposed, including statistical analysis of pulse wave shape [56], assessing the level of perfusion through the perfusion index (the ratio of the amplitude of the pulsatile component of the PPG to its baseline) [56], assessing the similarity of successive pulse wave shapes using template matching [86] or dynamic time warping [87], and deep learning [88].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [87]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Faires, J. D. (1978) · Cited by 6,711
The Levenberg-Marquardt algorithm: Implementation and theory
Morè, J. J. (1978) · Lecture notes in mathematics · doi:10.1007/bfb0067700 · Cited by 5,796
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Exact indexing of dynamic time warping
Keogh, E., & Ratanamahatana, C. A. (2004) · Knowledge and Information Systems · doi:10.1007/s10115-004-0154-9 · Cited by 1,962
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291140 · Cited by 326
Saeed, M., Lieu, C., RABER, G., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166854 · Cited by 273
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Signal processing methods for heart rate variability
Clifford, G. D. (2002) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-noa0mqzyn · Cited by 131
Self-citation
Research works printed but not linked: 14
- Addison P S Watson J N, 2010
- Clifford G D, 2011, Comput. Cardiol., 38, 285
- Graybeal J M Petterson M T, 2004, Proc. 26th Annu. Int. Conf. IEEE EMBS, 5363
- Huang B Kinsner W, 2002, Proc. 2002 IEEE Canadian Conf. on Electrical and Computer Engineering, 1105
- Krishnan R Natarajan B Warren S, 2008, Proc. 17th Int. Conf. on Computer Communications and Networks ICCCN '08, 1
- Krishnan R Natarajan B Warren S, 2008, IEEE Int. Conf. on Acoustics, Speech and Signal Processing, 613
- Lee C M Zhang Y T, 2003, IEEE EMBS Asian-Pacific Conf. on Biomed. Eng., 194
- Lee H W, 2007, Int. J. Control Autom. Syst., 5, 701
- Reddy K A Kumar V J, 2007, Proc. IEEE Instrumentation and Measurement Technology Conf. IMTC, 1
- Relente A R Sison L G, 2002, Proc. 2nd Joint EMBS/BMES Conf., 1769
- Sukanesh R, 2010, Biomed. Softw. Comput. Hum. Sci., 16, 135
- Vullings H J L M Verhaegen M H G Verbruggen H B, 1998, Proc. 20th Annu. Conf. IEEE EMBS, 163
- Yao J Warren S, 2005, IEEE-EMBS 27th Annu. Int. Conf. of the Engineering in Medicine and Biology Society, 3585
- Zong W, 2003, Comput. Cardiol., 30, 259
Cited by
Sorted by citations
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Optimal Signal Quality Index for Photoplethysmogram Signals
Elgendi, M. (2016) · Bioengineering · doi:10.3390/bioengineering3040021 · Cited by 338
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 263
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Current progress of photoplethysmography and SPO2 for health monitoring
TAMURA, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 274
Data, M. C. (2020) · OAPEN (The OAPEN Foundation) · doi:10.1007/978-3-319-43742-2 · Cited by 273
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V., Gederi, E., Osipov, M., Behar, J. A., Malhotra, A., Penzel, T., & Clifford, G. D. (2013) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 234
Self-citationWearable-Based Affect Recognition—A Review
Schmidt, P., Reiss, A., Dürichen, R., & Laerhoven, K. V. (2019) · Sensors · doi:10.3390/s19194079 · Cited by 291
Ghassemi, M., Pimentel, M. A. F., Naumann, T., Brennan, T. J., Clifton, D. A., Szolovits, P., & Feng, M. (2015) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v29i1.9209 · Cited by 202
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 233
Self-citationMejía‐Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00779 · Cited by 178
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
A review of current sleep screening applications for smartphones
Behar, J. A., Roebuck, A., Domingos, J. S., Gederi, E., & Clifford, G. D. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/7/r29 · Cited by 134
Self-citationThe PhysioNet/Computing in Cardiology Challenge 2015: Reducing false arrhythmia alarms in the ICU
Clifford, G. D., Silva, I., Moody, B., Li, Q., Kella, D., Shahin, A., Kooistra, T., Perry, D., & Mark, R. G. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7408639 · Cited by 136
Self-citationSignal quality and data fusion for false alarm reduction in the intensive care unit
Li, Q., & Clifford, G. D. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2012.07.015 · Cited by 125
Self-citationA systematic literature review on vision based gesture recognition techniques
Al‐Shamayleh, A. S., Ahmad, R. B., Abushariah, M. A. M., Alam, K. A., & Jomhari, N. (2018) · Multimedia Tools and Applications · doi:10.1007/s11042-018-5971-z · Cited by 130
A Review of IoT-Enabled Mobile Healthcare: Technologies, Challenges, and Future Trends
Yang, Y., Wang, H., Jiang, R., Guo, X., Cheng, J., & Chen, Y. J. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3144400 · Cited by 126
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 121
Diagnostic assessment of a deep learning system for detecting atrial fibrillation in pulse waveforms
Poh, M., Poh, Y. C., Chan, P., Wong, C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Chu, D. W., & Siu, C. (2018) · Heart · doi:10.1136/heartjnl-2018-313147 · Cited by 118
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
SleepAp: An Automated Obstructive Sleep Apnoea Screening Application for Smartphones
Behar, J. A., Roebuck, A., Shahid, M., Daly, J., Hallack, A., Palmius, N., Stradling, J. R., & Clifford, G. D. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2307913 · Cited by 112
Self-citationA Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things
Naeini, E. K., Azimi, I., Rahmani, A. M., Liljeberg, P., & Dutt, N. D. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.04.074 · Cited by 92
An Algorithm for Real-Time Pulse Waveform Segmentation and Artifact Detection in Photoplethysmograms
Fischer, C., Dömer, B., Wibmer, T., & Penzel, T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2518202 · Cited by 95
Epidemiology of Coronavirus COVID-19: Forecasting the Future Incidence in Different Countries
Stübinger, J., & Schneider, L. (2020) · Healthcare · doi:10.3390/healthcare8020099 · Cited by 88
Wrapper method for feature selection to classify cardiac arrhythmia
Mustaqeem, A., Anwar, S. M., Majid, M., & Khan, A. R. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037650 · Cited by 82
A Supervised Approach to Robust Photoplethysmography Quality Assessment
Pereira, T., Gadhoumi, K., Ma, M., Liu, X., Xiao, R., Colorado, R. A., Keenan, K. J., Meisel, K. M., & Hu, X. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2909065 · Cited by 80
Robust PPG motion artifact detection using a 1-D convolution neural network
Goh, C., Tan, L. K., Lovell, N. H., Ng, S., Tan, M. P., & Lim, E. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105596 · Cited by 83
Objective Assessment of Upper Limb Mobility for Post-stroke Rehabilitation
Zhang, Z., Fang, Q., & Gu, X. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2477095 · Cited by 80
Real-Time PPG Signal Quality Assessment System for Improving Battery Life and False Alarms
Vadrevu, S., & Manikandan, M. S. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2891636 · Cited by 83
Non-invasive Fetal ECG Signal Quality Assessment for Multichannel Heart Rate Estimation
Andreotti, F., Gräßer, F., Malberg, H., & Zaunseder, S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2675543 · Cited by 78
Roy, M. S., Gupta, R., Chandra, J. K., Sharma, K. D., & Talukdar, A. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2829488 · Cited by 76
Evaluation of the Time Stability and Uniqueness in PPG-Based Biometric System
Hwang, D. Y., Taha, B., Lee, D. S., & Hatzinakos, D. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.3006313 · Cited by 76
Signal recovery in imaging photoplethysmography
Holton, B. D., Mannapperuma, K., Lesniewski, P. J., & Thomas, J. C. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/11/1499 · Cited by 73
Yue, M., Yang, Y., Fu, R., Lü, C., Zhao, L., Hu, Y., Li, C., Wu, Y., Liu, H., & Chen, W. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800257 · Cited by 72
Reddy, G. N. K., Manikandan, M. S., & Murty, N. V. L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2971132 · Cited by 73
Schmidt, M. U., Baumert, M., Porta, A., Malberg, H., & Zaunseder, S. (2014) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2014.2354313 · Cited by 64
Probabilistic Estimation of Respiratory Rate from Wearable Sensors
Pimentel, M. A. F., Charlton, P. H., & Clifton, D. A. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_10 · Cited by 59
Zhang, Y., Wei, S., Li, Z., & Liu, C. (2018) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-018-0411-0 · Cited by 58
Optimized Signal Quality Assessment for Photoplethysmogram Signals Using Feature Selection
Mohagheghian, F., Han, D., Peitzsch, A. G., Nishita, N., Ding, E., Dickson, E. L., DiMezza, D., Otabil, E. M., Noorishirazi, K., Scott, J., et al. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3158582 · Cited by 57
Transfer learning from ECG to PPG for improved sleep staging from wrist-worn wearables
Li, Q., Li, Q., Cakmak, A. S., Poian, G. D., Bliwise, D. L., Vaccarino, V., Shah, A. J., & Clifford, G. D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf1b0 · Cited by 55
Self-citationImplementation of Artifact Detection in Critical Care: A Methodological Review
Nizami, S., Green, J. R., & McGregor, C. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243724 · Cited by 52
Chromik, J., Klopfenstein, S. A. I., Pfitzner, B., Sinno, Z.-C., Bert Arnrich, A., Balzer, F., & Poncette, A.-S. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.843747 · Cited by 67
On-line and dynamic time warping for time series data mining
Li, H. (2014) · International Journal of Machine Learning and Cybernetics · doi:10.1007/s13042-014-0254-0 · Cited by 53
Pereira, T., Ding, C., Gadhoumi, K., Tran, N., Colorado, R. A., Meisel, K. M., & Hu, X. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab5b84 · Cited by 53
Robust detection of heart beats in multimodal data
Silva, I., Moody, B., Behar, J. A., Johnson, A. E. W., Oster, J., Clifford, G. D., & Moody, G. B. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/8/1629 · Cited by 53
Self-citationpyPPG: a Python toolbox for comprehensive photoplethysmography signal analysis
Goda, M. Á., Charlton, P. H., & Behar, J. A. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad33a2 · Cited by 59
Creation of a Robust and Generalizable Machine Learning Classifier for Patient Ventilator Asynchrony
Rehm, G. B., Han, J., Kuhn, B. T., Delplanque, J., Anderson, N., Adams, J. Y., & Chuah, C. (2018) · Methods of Information in Medicine · doi:10.3414/me17-02-0012 · Cited by 51
Convertino, V. A., Schauer, S. G., Weitzel, E. K., Cardin, S., Stackle, M. E., Talley, M. J., Sawka, M. N., & Inan, O. T. (2020) · Sensors · doi:10.3390/s20226413 · Cited by 49
Evaluation of the signal quality of wrist-based photoplethysmography
Pradhan, N., Rajan, S., & Adler, A. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab225a · Cited by 50
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
Zia, J., Kimball, J., Hersek, S., Shandhi, M. M. H., Semiz, B., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931348 · Cited by 48
“work has utilized the DTW distance between ECG signals and reference templates as a feature for classifying ECG segments [21]–[23].”
MethodMoscato, S., Giudice, S. L., Massaro, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22155831 · Cited by 51
False alarm reduction in critical care
Clifford, G. D., Silva, I., Moody, B., Li, Q., Kella, D., Chahin, A. B., Kooistra, T., Perry, D., & Mark, R. G. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/8/e5 · Cited by 49
Self-citationAutomated signal quality assessment of mobile phone-recorded heart sound signals
Springer, D., Brennan, T. J., Ntusi, N., Abdelrahman, H. Y., Zuhlke, L. J., Mayosi, B. M., Tarassenko, L., & Clifford, G. D. (2016) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1213902 · Cited by 46
Self-citationRobust PPG-Based Mental Workload Assessment System Using Wearable Devices
Beh, W.-K., Wu, Y., & Wu, A.-Y. A. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3138639 · Cited by 52
Signal quality in cardiorespiratory monitoring
Clifford, G. D., & Moody, G. B. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/e01 · Cited by 45
Self-citationRespiratory rate estimation during triage of children in hospitals
Shah, S. A., Fleming, S., Thompson, M., & Tarassenko, L. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1105316 · Cited by 44
Non-Contact Vital Sign Monitoring in the Clinic
Villarroel, M., Jorge, J., Pugh, C. W., & Tarassenko, L. (2017) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2017.43 · Cited by 46
Statistical arbitrage with optimal causal paths on high-frequency data of the S&P 500
Stübinger, J. (2018) · Quantitative Finance · doi:10.1080/14697688.2018.1537503 · Cited by 44
Roh, D., & Shin, H. (2021) · Sensors · doi:10.3390/s21062188 · Cited by 43
Mejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00447-y · Cited by 42
Guo, Z., Ding, C., Hu, X., & Rudin, C. D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac3b3d · Cited by 40
Deep convolutional neural network-based signal quality assessment for photoplethysmogram
Shin, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105430 · Cited by 42
Akhbari, M., Shamsollahi, M. B., Jutten, C., Armoundas, A. A., & Sayadi, O. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/2/203 · Cited by 41
Zheng, Y., Wu, C., Cai, P., Zhong, Z., Huang, H., & Jiang, Y. (2023) · Internet of Things · doi:10.1016/j.iot.2023.101007 · Cited by 40
Sabeti, E., Reamaroon, N., Mathis, M. R., Gryak, J., Sjoding, M. W., & Najarian, K. (2019) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2019.100222 · Cited by 40
A Deep Learning–based PPG Quality Assessment Approach for Heart Rate and Heart Rate Variability
Naeini, E. K., Sarhaddi, F., Azimi, I., Liljeberg, P., Dutt, N. D., & Rahmani, A. M. (2023) · ACM Transactions on Computing for Healthcare · doi:10.1145/3616019 · Cited by 39
Using Lempel–Ziv Complexity to Assess ECG Signal Quality
Zhang, Y., Wei, S., Maria, C. D., & Liu, C. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0165-5 · Cited by 39
Quality Assessment for the Photoplethysmogram (PPG)
Orphanidou, C. (2017) · SpringerBriefs in bioengineering · doi:10.1007/978-3-319-68415-4_3 · Cited by 39
Adaptive template matching of photoplethysmogram pulses to detect motion artefact
Lim, P. K., Ng, S., Lovell, N. H., Yu, Y. P., Tan, M. P., McCombie, D. B., Lim, E., & Redmond, S. J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadf1e · Cited by 39
Determinants of photoplethysmography signal quality at the wrist
Charlton, P. H., Marozas, V., Mejía‐Mejía, E., Kyriacou, P. A., & Mant, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000585 · Cited by 38
Vadrevu, S., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2917157 · Cited by 39
Waveform Analysis to Estimate Respiratory Rate
Charlton, P. H., Villarroel, M., & Salguiero, F. (2016) · Springer eBooks · doi:10.1007/978-3-319-43742-2_26 · Cited by 39
Papini, G. B., Fonseca, P. M., Aubert, X. L., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036776 · Cited by 36
Arterial path selection to measure pulse wave velocity as a surrogate marker of blood pressure
Radha, M., Zhang, G., Gelissen, J., de Groot, K., Haakma, R., & Aarts, R. M. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa5b40 · Cited by 36
Chan, M., Ganti, V. G., & Inan, O. T. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3144990 · Cited by 37
Chiang, P.-Y., Chao, P. C.-P., Tarng, D., & Yang, C. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701780 · Cited by 35
Escobar, B., Villa, R. A. T., & Kyriacou, P. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01848 · Cited by 35
Cakmak, A. S., Alday, E. A. P., Poian, G. D., Rad, A. B., Metzler, T. J., Neylan, T. C., House, S. L., Beaudoin, F. L., An, X., Stevens, J. S., et al. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3053909 · Cited by 35
Self-citationMejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106222 · Cited by 36
Chen, J., Sun, K., Sun, Y., & Li, X. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630758 · Cited by 34
Robust classification of neonatal apnoea-related desaturations
Monasterio, V., Burgess, F., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1503 · Cited by 34
Self-citationPapini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 32
Huthart, S., Elgendi, M., Zheng, D., Stansby, G. P., & Allen, J. (2020) · Frontiers in Digital Health · doi:10.3389/fdgth.2020.619692 · Cited by 35
A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods
Desquins, T., Bousefsaf, F., Pruski, A., & Maaoui, C. (2022) · Applied Sciences · doi:10.3390/app12199582 · Cited by 35
Reddy, G. N. K., Manikandan, M. S., Murty, N. V. L. N., & Cenkeramaddi, L. R. (2023) · IEEE Access · doi:10.1109/access.2023.3269584 · Cited by 32
Dynamic ECG Signal Quality Evaluation Based on the Generalized bSQI Index
Liu, F., Liu, C., Zhao, L., Jiang, X., Zhang, Z., Li, J., Wei, S., & Zhang, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2860056 · Cited by 31
Alam, S., Gupta, R., & Sharma, K. D. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3067238 · Cited by 30
Gazi, A. H., Sundararaj, S., Harrison, A. B., Gurel, N. Z., Wittbrodt, M. T., Alkhalaf, M. L., Soudan, M., Levantsevych, O. M., Haffar, A., Shah, A. J., et al. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630415 · Cited by 30
Remote Heart Rate Estimation by Signal Quality Attention Network
Gao, H., Wu, X., Geng, J., & Lv, Y. (2022) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw56347.2022.00230 · Cited by 28
Feli, M., Azimi, I., Anzanpour, A., Rahmani, A. M., & Liljeberg, P. (2023) · Smart Health · doi:10.1016/j.smhl.2023.100390 · Cited by 29
Roy, M. S., Roy, B., Gupta, R., & Sharma, K. D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3028935 · Cited by 29
Cardiac arrhythmia classification using multi-modal signal analysis
Kalidas, V., & Tamil, L. S. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/8/1253 · Cited by 28
Transfer learning of CNN-based signal quality assessment from clinical to non-clinical PPG signals
Zanelli, S., El‐Yacoubi, M. A., Hallab, M., & Ammi, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629640 · Cited by 28
Beat-Based PPG-ABP Cleaning Technique for Blood Pressure Estimation
Salah, M., Omer, O. A., Hassan, L., Ragab, M., Hassan, A. M., & Abdelreheem, A. A. (2022) · IEEE Access · doi:10.1109/access.2022.3175436 · Cited by 29
Respiratory rate monitoring from the photoplethysmogram via sparse signal reconstruction
Zhang, X., & Ding, Q. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/7/1105 · Cited by 28
Semi-supervised detection of intracranial pressure alarms using waveform dynamics
Scalzo, F., & Hu, X. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/4/465 · Cited by 27
Machine and Deep Learning Algorithms for Wearable Health Monitoring
Fei, C., Liu, R., Li, Z., Wang, T., & Baig, F. N. (2021) · Health information science · doi:10.1007/978-3-030-68723-6_6 · Cited by 28
Zaunseder, S., Vehkaoja, A. T., Fleischhauer, V., & Antink, C. H. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103538 · Cited by 26
Metadata
- Authors
- Li, Q., & Clifford, G. D.
- Affiliations
- Shandong University (CN)
- University of Oxford (GB)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1491-1501
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1989977532
- Cited by
- 274
- References
- 31
- Citations by year
- 2026: 18 · 2025: 13 · 2024: 17 · 2023: 26 · 2022: 28 · 2021: 25 · 2020: 22 · 2019: 18 · 2018: 25 · 2017: 20 · 2016: 25 · 2015: 15 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, signal quality assessment, dynamic time warping, template matching, multilayer perceptron, arrhythmia detection, intensive care monitoring
- MeSH terms
- Algorithms, Artificial Intelligence, Humans, Quality Control, Time Factors, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review