Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Garber, C. E., Blissmer, B., Deschenes, M. R., Franklin, B. A., Lamonte, M. J., Lee, I.-M., Nieman, D. C., & Swain, D. P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318213fefb · Cited by 9,319
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1×
“Afterward, this the speed was increased by 1 km h−1 every 2 min until reaching 85% of the heart rate (HRmax) previously calculated using the equation proposed by Tanaka et al (2001).”
MethodFall in skin temperature of exercising man.
Torii, M., Yamasaki, M., Sasaki, T., & Nakayama, H. (1992) · British Journal of Sports Medicine · doi:10.1136/bjsm.26.1.29 · Cited by 145
Thermoregulatory and thermal control in the human cutaneous circulation
Kellogg, D. L. (2010) · Frontiers in Bioscience · doi:10.2741/s105 · Cited by 137
Describing individual variation in local sweating during exercise in a temperate environment
Bain, A. R., Deren, T. M., & Jay, O. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1788-9 · Cited by 47 · cited 2×
“…with the thermocouples at 15 min in the pre-exercise condition (31.8 ± 0.5 ◦C) with those of other studies, similar MTSK values of 31.8 ± 0.3 ◦C (Burdon et al 2010), 31.7 ± 0.3 ◦C (Bain and Jay 2011), and 31.8 ± 0.7 ◦C (Bain et al 2011) are found in studies with similar environmental conditions.”
MethodResultInfluential
Cited by
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Self-citationMoreira, D. G., Costello, J. T., Brito, C. J., Adamczyk, J. G., Ammer, K., Bach, A. J. E., Costa, C. M. A., Eglin, C., Fernandes, A. A., Fernández-Cuevas, I., et al. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.07.006 · Cited by 406
Self-citationWearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“Surface temperature has been used to monitor athletic performance [149], fatigue [130], emotional state [150]–[152], ovulation cycle [153], and sleep states [131].”
3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Ota, H., Chao, M., Gao, Y., Wu, E., Tai, L.-C., Chen, K., Matsuoka, Y., Iwai, K., Fahad, H. M., Gao, W., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00247 · Cited by 154
Surgeons' and surgical trainees' acute stress in real operations or simulation: A systematic review
Georgiou, K., Larentzakis, A., & Papavassiliou, A. G. (2017) · The Surgeon · doi:10.1016/j.surge.2017.06.003 · Cited by 69
Metadata
- Authors
- Fernandes, A. D. A., Amorim, P. R. D. S., Brito, C. J., de Moura, A. G., Moreira, D. G., Costa, C. M. A., Sillero-Quintana, M., & Marins, J. C. B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-01-07
- Volume
- 35
- Issue
- 2
- Pages
- 189-203
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2164336336
- Cited by
- 145
- References
- 6
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography. https://app.cochat.ai/papers/10.1088/0967-3334/35/2/189
- The paper
- Fernandes, A. D. A., Amorim, P. R. D. S., Brito, C. J., de Moura, A. G., Moreira, D. G., Costa, C. M. A., Sillero-Quintana, M., & Marins, J. C. B. (2014). Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography. Physiological Measurement. https://doi.org/10.1088/0967-3334/35/2/189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.