Microvascular imaging: techniques and opportunities for clinical physiological measurements
Open accessThe DOI matches its Crossref record; 140 of the 140 references it cites were found in a registry or an index.
Abstract
The microvasculature presents a particular challenge in physiological measurement because the vessel structure is spatially inhomogeneous and perfusion can exhibit high variability over time. This review describes, with a clinical focus, the wide variety of methods now available for imaging of the microvasculature and their key applications. Laser Doppler perfusion imaging and laser speckle contrast imaging are established, commercially-available techniques for determining microvascular perfusion, with proven clinical utility for applications such as burn-depth assessment. Nailfold capillaroscopy is also commercially available, with significant published literature that supports its use for detecting microangiopathy secondary to specific connective tissue diseases in patients with Raynaud's phenomenon. Infrared thermography measures skin temperature and not perfusion directly, and it has only gained acceptance for some surgical and peripheral microvascular applications. Other emerging technologies including imaging photoplethysmography, optical coherence tomography, photoacoustic tomography, hyperspectral imaging, and tissue viability imaging are also described to show their potential as techniques that could become established tools for clinical microvascular assessment. Growing interest in the microcirculation has helped drive the rapid development in perfusion imaging of the microvessels, bringing exciting opportunities in microvascular research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008 · cited 5×
“TiVi and LSCI provided less deep measurements than the laser Doppler instrument, which could not detect the vasodilatation caused by methylnicotinate in the superficial skin. Petersen et al (2010) have also reported the evidence that TiVi may be more sensitive to vasoconstrictive pharmacological stimuli than laser Dop…”
BackgroundMethodInfluentialPhotoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 3×
“Traditional photoplethysmography (PPG) is a non-invasive contact optical method to detect the cardiovascular pulse wave, usually from the peripheral tissues (Allen 2007).”
BackgroundMethodInfluentialSelf-citationMedical hyperspectral imaging: a review
Lu, G., & Fei, B. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.010901 · Cited by 2,291
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205 · cited 1×
“An excellent review of the technology is given by Beard (2011).”
BackgroundTearney, G. J., Regar, E., Akasaka, T., Adriaenssens, T., Barlis, P., Bezerra, H. G., Bouma, B., Bruining, N., Cho, J.-M., Chowdhary, S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.079 · Cited by 1,874
Transplantation of ex vivo expanded endothelial progenitor cells for therapeutic neovascularization
Kalka, C., Masuda, H., Takahashi, T., Kalka-Moll, W. M., Silver, M., Kearney, M., Li, T., Isner, J. M., & Asahara, T. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.7.3422 · Cited by 1,863 · cited 1×
“Often animal model studies are performed to study perfusion in the processes of angiogenesis and tumour development (Kalka et al 2000, Iimuro et al 2004, Ferraro et al 2010), as well as studying responses to therapy (Yang et al 2009).”
BackgroundRemote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719 · cited 1×
“The time-varying intensity modulation is strongly affected by relative movement of the camera and body so image processing methods are used to reduce the effect of motion artefacts e.g. by averaging of pixels or Fourier analysis techniques (Wieringa et al 2005, Verkruysse et al 2008).”
MethodOptical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138 · cited 2×
“A Michelson interferometer is often used to perform the low-coherence interferometry for OCT (Fujimoto et al 2000).”
MethodLaser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Infrared thermal imaging in medicine
Ring, E. F. J., & Ammer, K. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/r33 · Cited by 1,034 · cited 1×
“The falling price and improving performance of infrared imaging technology makes thermography one of the most accessible microvascular imaging techniques available to researchers (Ring and Ammer 2012).”
Background
Cited by
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Usability of four commercially-oriented EEG systems
David Hairston, W., Whitaker, K. W., Ries, A. J., Vettel, J. M., Cortney Bradford, J., Kerick, S. E., & McDowell, K. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046018 · Cited by 215
New insights into the origin of remote PPG signals in visible light and infrared
Moço, A. V., Stuijk, S., & de Haan, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-26068-2 · Cited by 168
“Multispectral PPG data, in VIS–IR, may find clinical value in skin health assessments 9,10 .”
Metadata
- Authors
- Allen, J., & Howell, K.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-06-09
- Volume
- 35
- Issue
- 7
- Pages
- R91-R141
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2017624386
- Cited by
- 208
- References
- 140
- FWCI
- 21.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.