A careful look at ECG sampling frequency and R-peak interpolation on short-term measures of heart rate variability.
The DOI matches its Crossref record; 88 of the 89 references it cites were found in a registry or an index.
Abstract
As the literature on heart rate variability (HRV) continues to burgeon, so too do the challenges faced with comparing results across studies conducted under different recording conditions and analysis options. Two important methodological considerations are (1) what sampling frequency (SF) to use when digitizing the electrocardiogram (ECG), and (2) whether to interpolate an ECG to enhance the accuracy of R-peak detection. Although specific recommendations have been offered on both points, the evidence used to support them can be seen to possess a number of methodological limitations. The present study takes a new and careful look at how SF influences 24 widely used time- and frequency-domain measures of HRV through the use of a Monte Carlo-based analysis of false positive rates (FPRs) associated with two-sample tests on independent sets of healthy subjects. HRV values from the first sample were calculated at 1000 Hz, and HRV values from the second sample were calculated at progressively lower SFs (and either with or without R-peak interpolation). When R-peak interpolation was applied prior to HRV calculation, FPRs for all HRV measures remained very close to 0.05 (i.e. the theoretically expected value), even when the second sample had an SF well below 100 Hz. Without R-peak interpolation, all HRV measures held their expected FPR down to 125 Hz (and far lower, in the case of some measures). These results provide concrete insights into the statistical validity of comparing datasets obtained at (potentially) very different SFs; comparisons which are particularly relevant for the domains of meta-analysis and mobile health.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, recent development on this topic, relying on Monte Carlo-based analysis of false positive rates, showed that when R-peak interpolation (i.e., mathematical estimation of the digitized signal performed to enhance the R-wave fiducial point) was applied prior to HRV calculation, sampling rate could even be lower than 100 Hz, and without R-peak interpolation the analysis could be considered as”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Ellis et al., 2015
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Why Most Published Research Findings Are False
Ioannidis, J. P. A. (2005) · PLoS Medicine · doi:10.1371/journal.pmed.0020124 · Cited by 10,505
Cohen, J. (1992) · Psychological Bulletin · doi:10.1037//0033-2909.112.1.155 · Cited by 8,771
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 3×
“R-peak detection was accomplished using rpeakdetect.m (Clifford 2003), an instantiation of the classic digital filter–based algorithm by Pan and Tompkins (1985).”
MethodInfluentialWhy Most Published Research Findings Are False
Ioannidis, J. P. A. (2005) · CHANCE · doi:10.1080/09332480.2005.10722754 · Cited by 4,702 · cited 2×
“In the face of heightened attention paid towards the prevalence of publication bias (e.g. Ioannidis 2005), meta-analysis—a set of statistical methods designed to illuminate patterns of similarity across studies—has now reached a favored position in many disciplines (e.g. Cumming 2012).”
BackgroundMethodHeart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962 · cited 5×
“Taken together, these methodological issues suggest that widely cited recommendations concerning minimum SFs and the benefits of R-peak interpolation (e.g. Task Force 1996a, Berntson et al 1997) may be due for a careful re-evaluation.”
BackgroundMethodInfluentialRank transformations as a bridge between parametric and nonparametric statistics
Conover, W. J., & Iman, R. L. (1981) · The American Statistician · doi:10.1080/00031305.1981.10479327 · Cited by 3,922 · cited 1×
“Another option utilizes a rank-based (nonparametric) test (for an overview, see Conover and Iman 1981), eliminating the need for any data transformations; for example, the Mann–Whitney–Wilcoxon U-test.”
MethodThayer, J. F., Åhs, F., Fredrikson, M., Sollers, J. J., & Wager, T. D. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2011.11.009 · Cited by 3,224 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundSelf-citation
Research works printed but not linked: 5
- Abboud S, 1995, Comput. Cardiol., 461
- Castiglioni P, 2003, Comput. Cardiol., 481
- Ellis R J, 2008, Biomed. Sci. Instrum., 44, 392
- Kay M, 2011, World Health Organ.
- 10.1037/1082-989x.5.2.230 · doi:10.1037/1082-989x.5.2.230 · Paper page
Cited by
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“…to enhance the R-wave fiducial point) was applied prior to HRV calculation, sampling rate could even be lower than 100 Hz, and without R-peak interpolation the analysis could be considered as reliable down to 125 Hz for all measures, and far lower in case of specific measures (Ellis et al., 2015).”
MethodSelf-citationErshad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N.-I., Rao, Z., Guevara, R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17619-1 · Cited by 355
Quigley, K. S., Gianaros, P. J., Norman, G. J., Jennings, J. R., Berntson, G. G., & de Geus, E. J. C. (2024) · Psychophysiology · doi:10.1111/psyp.14604 · Cited by 225
Electrocardiogram Sampling Frequency Range Acceptable for Heart Rate Variability Analysis
Kwon, O., Jeong, J., Kim, H. B., Kwon, I. H., Park, S. Y., Kim, J. E., & Choi, Y. (2018) · Healthcare Informatics Research · doi:10.4258/hir.2018.24.3.198 · Cited by 180
“HRV is known to be associated with the interplay of the sympathetic and parasympathetic autonomic nervous systems [15].”
BackgroundMethodHidden Signals—The History and Methods of Heart Rate Variability
Ernst, G. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00265 · Cited by 201
“A recent exploration described stable measures at sampling rates of 125 Hz or lower (88).”
BackgroundHeart rate variability measure in breast cancer patients and survivors: A systematic review
Arab, C., Dias, D. P. M., Barbosa, R. T. D. A., de Carvalho, T. D., Valenti, V. E., Crocetta, T. B., Ferreira, M., de Abreu, L. C., & Ferreira, C. (2016) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2016.02.018 · Cited by 120
“In brief, all methods initially rely on proper data acquisition and processing, including the choice of appropriate sampling rate (Durosier et al., 2014; Ellis et al., 2015; Hejjel and Roth, 2004) and employment of efficient algorithms capable of detecting cardiac cycles in electrocardiogram (ECG) and/or pulsatile art…”
MethodDantas, E. M., Kemp, A. H., Andreão, R. V., da Silva, V. J. D., Brunoni, A. R., Hoshi, R. A., Benseñor, I. M., Lotufo, P. A., Ribeiro, A. L. P., & Mill, J. G. (2018) · Psychophysiology · doi:10.1111/psyp.13052 · Cited by 90
Béres, S., & Hejjel, L. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102589 · Cited by 76
Esco, M. R., Williford, H. N., Flatt, A. A., Freeborn, T. J., & Nakamura, F. Y. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3759-x · Cited by 78
Sigrist, C., Mürner-Lavanchy, I. M., Peschel, S. K. V., Schmidt, S. J., Kaess, M., & Koenig, J. (2020) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2020.10.026 · Cited by 73
Self-citationKommers, D. R., Joshi, R., van Pul, C., Atallah, L., Feijs, L. M. G., Oei, S. G., Oetomo, S. B., & Andriessen, P. (2016) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.11.059 · Cited by 72
“Notably, ECG sampled at 125 Hz have proven to be sufficient for determining HRV-based features (15).”
Garcia-Gancedo, L., Kelly, M. L., Lavrov, A., Parr, J., Hart, R., Marsden, R., Turner, M. R., Talbot, K., Chiwera, T., Shaw, C. E., et al. (2019) · JMIR mHealth and uHealth · doi:10.2196/13433 · Cited by 55
“It was expected that physical activity and tRR data would be continuously captured by this sensor (extracted from 1 kHz ECG data, enough for HRV analysis [24]; full ECG data are not available with the sensor configuration utilized).”
MethodKim, Y.-J., Lee, J., Hong, H., Park, S., & Ryu, W. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202200873 · Cited by 55
How Live Performance Moves the Human Heart
Shoda, H., Adachi, M., & Umeda, T. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154322 · Cited by 65
“However, the recent literature reports that the sampling frequency of 125 Hz is as valid as that of 1000 Hz [12], at least for healthy participants [13].”
BackgroundKoenig, J., Abler, B., Agartz, I., Åkerstedt, T., Andreassen, O. A., Anthony, M., Bär, K., Bertsch, K., Brown, R. C., Brunner, R. M., et al. (2020) · Psychophysiology · doi:10.1111/psyp.13688 · Cited by 58
Self-citationDobbins, C., & Fairclough, S. H. (2018) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2018.2840153 · Cited by 48
“This sampling rate was selected as it was considered to be a suitable frequency at which to obtain a signal that did not suffer from jitter [24].”
BackgroundKemp, A. H., Koenig, J., Thayer, J. F., Bittencourt, M. S., Pereira, A. C., Santos, I. S., Dantas, E. M., Mill, J. G., Chor, D., Ribeiro, A. L. P., et al. (2016) · Psychosomatic Medicine · doi:10.1097/psy.0000000000000359 · Cited by 41
Self-citationAnalysis of sampling frequency and resolution in ECG signals
Krluku, E. A., & Gušev, M. (2017) · Telecommunications Forum (TELFOR) · doi:10.1109/telfor.2017.8249438 · Cited by 42
“[17] give a comprehensive analysis of different approaches to estimate the effect of the sampling frequency on heart rate variability.”
BackgroundReliability of short-term measurements of heart rate variability: Findings from a longitudinal study
Uhlig, S., Meylan, A., & Rudolph, U. (2020) · Biological Psychology · doi:10.1016/j.biopsycho.2020.107905 · Cited by 41
Figueiredo, D. H., Figueiredo, D. H., Moreira, A., Gonçalves, H. R., & Stanganélli, L. C. R. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003127 · Cited by 39
Jungmann, M., Vencatachellum, S., Ryckeghem, D. M. L. V., & Vögele, C. (2018) · JMIR Formative Research · doi:10.2196/10257 · Cited by 45
“Third, although a sampling rate of 256 Hz for ECG data collection is a well-established standard in the field (cf [75,82]), future studies may consider using a higher sampling rate to increase the temporal accuracy of heartbeat detection.”
BackgroundPapini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 37
Uncertainties in the Analysis of Heart Rate Variability: A Systematic Review
Lü, L., Zhu, T., Morelli, D., Creagh, A. P., Liu, Z., Yang, J., Liu, F., Zhang, Y., & Clifton, D. A. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3271595 · Cited by 40
“The sampling frequency at which the ECG signal is digitised is important in deriving HRV indices [97].”
BackgroundXiao, R., Ding, C., & Hu, X. (2022) · Journal of Imaging · doi:10.3390/jimaging8050120 · Cited by 37
“found that ECG collected at 125 Hz is good enough for HRV estimation without compromising accuracy [39].”
BackgroundKemp, A. H., López, S. R., Passos, V. M. A., Bittencourt, M. S., Dantas, E. M., Mill, J. G., Ribeiro, A. L. P., Thayer, J. F., Bensenor, I. M., & Lotufo, P. A. (2016) · Biological Psychology · doi:10.1016/j.biopsycho.2016.04.006 · Cited by 30
Self-citationVLSI Implementation of Lossless ECG Compression Algorithm for Low Power Devices
Tsai, T., & Hussain, M. A. (2020) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2020.2978554 · Cited by 31
“The sampling frequency of ECG devices is in range of a few hundred hertz to one-kilo hertz [5], [6].”
BackgroundAntikainen, E., Njoum, H., Kudelka, J., Branco, D., Rehman, R. Z. U., Macrae, V., Davies, K., Hildesheim, H., Emmert, K., Reilmann, R., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.968185 · Cited by 31
Timing errors and temporal uncertainty in clinical databases—A narrative review
Goodwin, A. J., Eytan, D., Dixon, W., Goodfellow, S. D., Doherty, Z. B., Greer, R. W., McEwan, A. L., Tracy, M. B., Laussen, P. C., Assadi, A., et al. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.932599 · Cited by 33
Srivastava, A., Pratiher, S., Alam, S., Hari, A., Banerjee, N., Ghosh, N., & Patra, A. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac6f40 · Cited by 32
Silva, R., Salvador, G. F. D., Bota, P. J., Fred, A. L. N., & Silva, H. (2022) · Neural Computing and Applications · doi:10.1007/s00521-022-07212-6 · Cited by 29
“[42] analysed the impact of lower SR on a signal originally sampled using a 1000 Hz SR, across 24 widely used time- and frequency-domain measures of HRV on healthy subjects.”
MethodErshad, F., Houston, M., Patel, S. B., Contreras, L., Koirala, B., Lu, Y., Rao, Z., Liu, Y., Dias, N., Haces‐Garcia, A., et al. (2023) · PNAS Nexus · doi:10.1093/pnasnexus/pgac291 · Cited by 30
Sato, S., Hiratsuka, T., Hasegawa, K., Watanabe, K., Obara, Y., Kariya, N., Shinba, T., & Matsui, T. (2023) · Sensors · doi:10.3390/s23083867 · Cited by 25
“The raw PPG data were 4× upsampled [58,59] and the first-order difference operation was applied, followed by a bandpass filter (range: 0.”
MethodUncertainty in heart rate complexity metrics caused by R-peak perturbations
Napoli, N. J., Demas, M., Mendu, S., Stephens, C. L., Kennedy, K. D., Harrivel, A. R., Bailey, R. E., & Barnes, L. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.10.009 · Cited by 23
Brain structural thickness and resting state autonomic function in adolescents with major depression
Koenig, J., Schreiner, M. W., Klimes‐Dougan, B., Ubani, B. N., Mueller, B. A., Kaess, M., & Cullen, K. R. (2018) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsy046 · Cited by 23
“Although pulse oximetry is acceptable for the analyses of HRV, future studies would do well to implement recordings of RVA using ECG at a higher sample-rate (Ellis et al., 2015).”
MethodSelf-citationEstévez‐Báez, M., Machado, C., García-Sánchez, B., Rodríguez, V., Santana, R. Á., Leisman, G., Carrera, J. M. E., Schiavi, A. J., Montes-Brown, J., & Arrufat‐Pié, E. (2019) · Brain Injury · doi:10.1080/02699052.2018.1553312 · Cited by 22
“This problem has been renewed in the last few years, and it has been conclusively shown (107) that it is not necessary to use some ‘recommended’ values of SF of the ECG (500–1000 Hz) for HRV analysis, when the original SF of the ECG recording has been over 125 Hz, and even better, when these signals are submitted to a…”
BackgroundAlbaba, A., Simões‐Capela, N., Wang, Y., Hendriks, R. C., Raedt, W. D., & Hoof, C. A. V. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104164 · Cited by 24
“A frequency of 256 Hz is considered an acceptable acquisition frequency when targeting HR/ HRV applications [24,25] and is also the lowest sampling frequency among datasets.”
Self-citationBrain activation and heart rate variability as markers of autonomic function under stress
Huber, A., Koenig, J., Bruns, B., Bendszus, M., Friederich, H., & Simon, J. J. (2025) · Scientific Reports · doi:10.1038/s41598-025-12430-8 · Cited by 25
Self-citationVLSI Implementation of Multi-Channel ECG Lossless Compression System
Tsai, T., Tung, N.-C., & Lin, D.-B. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3071757 · Cited by 20
Baek, H. J., Shin, J., Jin, G., & Cho, J. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0842-0 · Cited by 22
“showed that when R-peak refinement through interpolation was not utilized, the sampling rate of 125 Hz was required for HRV parameters to be close to the theoretically expected value [22].”
MethodLowering the Sampling Rate: Heart Rate Response during Cognitive Fatigue
Lee, K. F. A., Chan, E., Car, J., Gan, W., & Christopoulos, G. I. (2022) · Biosensors · doi:10.3390/bios12050315 · Cited by 18
“[31] used a subset of healthy controls from the Physikalisch-Technische Bundesanstalt Diagnostic ECG database [46], which did not involve any experimental manipulations.”
MethodResultWerth, J., Long, X., Zwartkruis-Pelgrim, E., Niemarkt, H. J., Chen, W., Aarts, R. M., & Andriessen, P. (2017) · Early Human Development · doi:10.1016/j.earlhumdev.2017.07.004 · Cited by 18
“Sample frequencies of 250 Hz and higher are sufficient for linear HRV analysis [29].”
BackgroundMoretta, T., Kaess, M., & Koenig, J. (2023) · Journal of Neural Transmission · doi:10.1007/s00702-022-02577-3 · Cited by 17
“Further, the estimation of RMSSD is more robust at lower sample rates compared to frequency-domain measures (Ellis et al. 2015).”
BackgroundSelf-citationBoursalie, O., Samavi, R., & Doyle, T. E. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0021-1 · Cited by 19
“Specifically, the ECG signal undergoes four pre-processing steps: filtering [24], detrending, ECG signal quality assessment [25] and R peak detection [26].”
MethodReliability of beat-to-beat blood pressure variability in older adults
Lohman, T., Sible, I. J., Shenasa, F., Engstrom, A. C., Kapoor, A., Alitin, J. P. M., Gaubert, A., Thayer, J. F., Ferrer, F., & Nation, D. A. (2024) · Scientific Reports · doi:10.1038/s41598-024-71183-y · Cited by 18
Self-citationKirti, K., Sohal, H., & Jain, S. (2018) · Biomedical & Pharmacology Journal · doi:10.13005/bpj/1556 · Cited by 15
Moreira, M. F., Gamboa, O. L., & Oliveira, M. A. P. (2023) · Journal of Pain · doi:10.1016/j.jpain.2023.07.026 · Cited by 17
Zhou, Y., Lindsey, B., Snyder, S., Bell, E. M., Reider, L., Vignos, M. F., Bar-Kochba, E., Mousavi, A. S., Parreira, J. D., Hanley, C. L., et al. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad252d · Cited by 16
Bahlinger, K., Lincoln, T. M., Krkovic, K., & Clamor, A. (2020) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2020.07.021 · Cited by 13
Eguchi, K., & Aoki, R. (2023) · IEEE Access · doi:10.1109/access.2023.3253933 · Cited by 15
Effects of R-R time series accuracy on heart rate variability indexes
Cassirame, J., Chevrolat, S., & Mourot, L. (2019) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2019006 · Cited by 11
Ten quick tips for electrocardiogram (ECG) signal processing
Chicco, D., Karaiskou, A.-Ι., & Vos, M. D. (2024) · PeerJ Computer Science · doi:10.7717/peerj-cs.2295 · Cited by 9
“…rates can compromise the precision of detecting R-wave fi ducial points and, therefore, greatly affect your Heart Rate Variability (HRV) analysis ( Garcia-Gonzalez, Fernandez-Chimeno & Ramos-Castro, 2004 ; Mahdiani et al., 2015 ; Ellis et al., 2015 ; Petelczyc et al., 2020 ; Lu et al., 2023 ).”
BackgroundOkwose, N. C., Russell, S. L., Rahman, M., Steward, C. J., Harwood, A. E., McGregor, G., Ninkovic, S. M., Maddock, H. L., Banerjee, P., & Jakovljević, D. G. (2022) · Health Science Reports · doi:10.1002/hsr2.984 · Cited by 9
Heekerens, J. B., Gross, J. J., Kreibig, S. D., Wingenfeld, K., & Roepke, S. (2023) · BMC Psychology · doi:10.1186/s40359-023-01209-z · Cited by 9
“However, current evidence suggests that any bias at sampling rates down to 125 Hz may be negligible [21].”
BackgroundMeasuring the Psychobiological Correlates of Daily Experience in Adolescents
Dockray, S., O’Neill, S. B., & Jump, O. (2019) · Journal of Research on Adolescence · doi:10.1111/jora.12473 · Cited by 8
Non-linear dynamics in ECG: a novel approach for robust classification of cardiovascular disorders
Behera, S. K., Bhattacharya, D., Aithal, N., & Sinha, N. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-024-00038-2 · Cited by 7
Translational perspectives on brain-heart interplay: From methodologies to clinical applications
Saibene, M., Gu, Y., Ballegaard, M., Andersen, T., Bardram, J. E., & Puthusserypady, S. K. (2026) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2026.111522 · Cited by 7
Complexity of heart rate variability during moral judgement of actions and omissions
Arutyunova, K. R., Bakhchina, A. V., Sozinova, I. M., & Alexandrov, Y. I. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e05394 · Cited by 8
“RR-intervals were recorded with a sampling rate of 250 Hz, which is frequently used in studies of HRV and can be considered adequate for the type of analysis performed in our work (Laborde et al., 2017; Ellis et al., 2015; Malik, 1996).”
MethodBrain structure and parasympathetic function during rest and stress in young adult women
Fridman, A., Yang, X., Vilgis, V., Keenan, K. E., Hipwell, A. E., Guyer, A. E., Forbes, E. E., & Casement, M. D. (2021) · Brain Structure and Function · doi:10.1007/s00429-021-02234-7 · Cited by 7
Hagmair, S., Braunisch, M. C., Bachler, M., Schmaderer, C., Hasenau, A.-L., Bauer, A., Rizas, K. D., Wassertheurer, S., & Mayer, C. C. (2016) · Physiological Measurement · doi:10.1088/1361-6579/38/1/1 · Cited by 10
Stoupi, N. A., Weijs, M. L., Imbach, L., & Lenggenhager, B. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1391437 · Cited by 8
Advanced analyses of physiological signals in the neonatal intensive care unit
Huvanandana, J., Thamrin, C., Tracy, M. B., Hinder, M. K., Nguyen, C., & McEwan, A. L. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa8a13 · Cited by 8
Kemp, A. H. (2018) · Minerva Access (University of Melbourne) · Cited by 6
Casanova‐Lizón, A., Sarabia, J. M., Pastor, D., Javaloyes, A., Peña‐González, I., & Moya‐Ramón, M. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20021528 · Cited by 8
“Although several studies have shown that the use of lower sampling rates could be used without significantly affecting HRV indices [54,57,58], the accuracy of measurements at higher sampling rates (1000 Hz) is perfect [59].”
BackgroundBizzego, A., & Furlanello, C. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/118943 · Cited by 6
“Effects of lower sampling frequency on the HRV indicators can be mitigated by signal interpolation [4].”
BackgroundCardiovagal Modulation in Young and Older Male Adults Following Acute Aerobic Exercise
Marôco, J. L., Pinto, M., Laranjo, S. M., Clara, S., Fernhall, B., & Melo, X. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1843-7974 · Cited by 5
“However, it is unlikely that a sample rate of 300 Hz fails to detect subtle changes in HRV following acute aerobic exercise, when combined with a cubic spine interpolation to increase accuracy in R peak detection [61].”
BackgroundNon-Linear Dynamics in ECG: A Novel Approach for Robust Classification of Cardiovascular DisordersPreprint
Bhattacharya, D., Behera, S. K., Aithal, N., & Sinha, N. (2024) · Research Square · doi:10.21203/rs.3.rs-5068005/v1 · Cited by 5
Poulsen, M. B., Julu, P. O. O., Røikjer, J., Drewes, A. M., & Brock, C. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1653881 · Cited by 4
Optimizing the Impact of Resampling on QRS Detection
Gušev, M., & Domazet, E. (2018) · Communications in computer and information science · doi:10.1007/978-3-030-00825-3_10 · Cited by 4
Spangler, D. P., Reis, H., Hsu, C., Zaręba, W., & Lane, R. (2024) · Psychosomatic Medicine · doi:10.1097/psy.0000000000001329 · Cited by 2
Isolation of Informative Features for the Analysis of QRS Complex in ECG Signals
Pashko, A. O., Krak, I. V., Стеля, О., & Khorozov, O. A. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-54215-3_26 · Cited by 4
Data Collection and Analysis of Psychophysiological Metrics During Movement Execution
Antonio, D. S., & Bigliassi, M. (2025) · Springer eBooks · doi:10.1007/978-3-031-90034-1_4 · Cited by 3
Ruffolo, I., Siddiqui, A. A., Nguyen, B., Dixon, W. G., Assadi, A., Greer, R. W., Schwartz, S. M., Brudno, M., Mariakakis, A. T., & Goodwin, A. (2025) · Physiological Measurement · doi:10.1088/1361-6579/ae1b70 · Cited by 3
“Achieving real-time PAT measurements requires making a few adjustments to our proposed approach so that it can be applied prospectively rather than retrospectively.”
Statistical Analysis of HRV Parameters for the Detection of Arrhythmia
Tripathi, K. M., Sohal, H., & Jain, S. (2020) · International Journal of Image and Graphics · doi:10.1142/s0219467820500369 · Cited by 3
Naber, A., Reiß, M., & Nahm, W. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.588120 · Cited by 2
Yokoyama, M., Miyazawa, T., Hanawa, H., Hirata, K., Yokoyama, H., Kubota, K., Fujino, T., Kanemura, N., Kaneko, H., Adili, A., et al. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105841 · Cited by 2
Barmak, O., Krak, I. V., Manziuk, E., Lytvynenko, V. I., & Kalyta, O. (2020) · Cited by 2
Schmaußer, M., Antink, C. H., Kaess, M., & Koenig, J. (2025) · Journal of Biological Rhythms · doi:10.1177/07487304251348516 · Cited by 1
“Previous research has shown that both the manual correction of R-peaks and subsequent interpolation substantially improve the reliability of the ECG signal (Ellis et al., 2015).”
Self-citationEffect of Bézier Interpolation on Similarity of Heartbeats in Electrocardiograms
Gušev, M., Tonkovikj, L., & Petrovski, N. (2022) · Telecommunications Forum (TELFOR) · doi:10.1109/telfor56187.2022.9983678 · Cited by 1
“Moreover, they believe that a sampling frequencies below 100 Hz will result in decreased performance and and that performance discrepancies for sampling frequencies above 125 Hz are especially negligible [13].”
BackgroundKowalsky, J. M. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Optimizing Heartbeat Classification using Bézier Interpolation
Gušev, M., Petrovski, N., & Tonkovikj, L. (2023) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro57284.2023.10159744
“for QRS detection show that sampling frequencies below 100 Hz will result in decreased performance [7], with a large number of wrong QRS detections for sampling frequencies below 200 Hz [8], while [9] concludes negligible performance discrepancies for sampling frequencies above 125 Hz having 120 Hz as a cut-off for su…”
BackgroundExposition personnelle au bruit et variabilité de la fréquence cardiaque
Aarbaoui, T. E. (2019) · theses.fr (ABES) · doi:10.70675/721ada16z0a5dz4305z9983z20fcd31ea414
Thrivikraman, A. S., Yogeshwaran, J., Sricharan, V. V. S., Preejith, S. P., & Sivaprakasam, M. (2024) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah61285.2024.10639557
“Such percentile based spread analysis as a validation methodology to understand best quality HRV measurement has been done in previous studies like [14] although the subject of validation was different in such studies.”
MethodEfficient FPGA Implementation of Hybrid ECG Data Compression for Remote Health Monitoring
Bharath, P., Vaithiyanathan, D., Giri, A., Verma, M. K., Verma, P., & Kaur, B. (2025) · International Conference on Computer, Electronics & Electrical Engineering & their Applications (IC2E3) · doi:10.1109/ic2e365635.2025.11167534
Heekerens, J. B., Gross, J. J., Kreibig, S. D., Wingenfeld, K., & Roepke, S. (2024) · Figshare · doi:10.6084/m9.figshare.26595131
Heekerens, J. B., Gross, J. J., Kreibig, S. D., Wingenfeld, K., & Roepke, S. (2024) · Figshare · doi:10.6084/m9.figshare.26595125
Heekerens, J. B., Gross, J. J., Kreibig, S. D., Wingenfeld, K., & Roepke, S. (2024) · Figshare · doi:10.6084/m9.figshare.26595134
Heekerens, J. B., Gross, J. J., Kreibig, S. D., Wingenfeld, K., & Roepke, S. (2024) · Figshare · doi:10.6084/m9.figshare.26595119
Suvish, Balota, J. E., Sheela, P., & Sundaram, S. (2026) · Electronics · doi:10.3390/electronics15215098
Stress Condition Moderates HRV Coupling in Parent–Child Dyads with Autism Spectrum Disorder
Li, J., Wu, Y., Yang, Y., van Dongen‐Boomsma, M., Staal, W., Long, X., Feng, J., Qiu, S., Han, T., Luo, X., et al. (2026) · Research in Autism · doi:10.1016/j.reia.2026.203057
Metadata
- Authors
- Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y.
- Affiliations
- National University of Singapore (SG)
- Fudan University (CN)
- The Ohio State University (US)
- Corresponding author
- Wang, Ye
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2015-08-03
- Volume
- 36
- Issue
- 9
- Pages
- 1827-1852
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2469606930
- Cited by
- 85
- References
- 89
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 12 · 2023: 11 · 2022: 10 · 2021: 4 · 2020: 11 · 2019: 5 · 2018: 10 · 2017: 8 · 2016: 6
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Singapore Ministry of Education (R-252-000-516-112)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, R-peak detection, false positive rate, statistical validity, time-domain HRV measures, frequency-domain HRV measures, cross-study comparability, mobile health, meta-analysis
- MeSH terms
- Adolescent, Adult, Aged, Electrocardiography, False Positive Reactions, Heart Rate, Humans, Middle Aged, Monte Carlo Method, Signal Processing, Computer-Assisted, Internet, Young Adult, Datasets as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.