A careful look at ECG sampling frequency and R-peak interpolation on short-term measures of heart rate variability.
The DOI matches its Crossref record; 88 of the 89 references it cites were found in a registry or an index.
Abstract
As the literature on heart rate variability (HRV) continues to burgeon, so too do the challenges faced with comparing results across studies conducted under different recording conditions and analysis options. Two important methodological considerations are (1) what sampling frequency (SF) to use when digitizing the electrocardiogram (ECG), and (2) whether to interpolate an ECG to enhance the accuracy of R-peak detection. Although specific recommendations have been offered on both points, the evidence used to support them can be seen to possess a number of methodological limitations. The present study takes a new and careful look at how SF influences 24 widely used time- and frequency-domain measures of HRV through the use of a Monte Carlo-based analysis of false positive rates (FPRs) associated with two-sample tests on independent sets of healthy subjects. HRV values from the first sample were calculated at 1000 Hz, and HRV values from the second sample were calculated at progressively lower SFs (and either with or without R-peak interpolation). When R-peak interpolation was applied prior to HRV calculation, FPRs for all HRV measures remained very close to 0.05 (i.e. the theoretically expected value), even when the second sample had an SF well below 100 Hz. Without R-peak interpolation, all HRV measures held their expected FPR down to 125 Hz (and far lower, in the case of some measures). These results provide concrete insights into the statistical validity of comparing datasets obtained at (potentially) very different SFs; comparisons which are particularly relevant for the domains of meta-analysis and mobile health.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, recent development on this topic, relying on Monte Carlo-based analysis of false positive rates, showed that when R-peak interpolation (i.e., mathematical estimation of the digitized signal performed to enhance the R-wave fiducial point) was applied prior to HRV calculation, sampling rate could even be lower than 100 Hz, and without R-peak interpolation the analysis could be considered as”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Ellis et al., 2015
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Why Most Published Research Findings Are False
Ioannidis, J. P. A. (2005) · PLoS Medicine · doi:10.1371/journal.pmed.0020124 · Cited by 10,505
Cohen, J. (1992) · Psychological Bulletin · doi:10.1037//0033-2909.112.1.155 · Cited by 8,771
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 3×
“R-peak detection was accomplished using rpeakdetect.m (Clifford 2003), an instantiation of the classic digital filter–based algorithm by Pan and Tompkins (1985).”
MethodInfluentialWhy Most Published Research Findings Are False
Ioannidis, J. P. A. (2005) · CHANCE · doi:10.1080/09332480.2005.10722754 · Cited by 4,702 · cited 2×
“In the face of heightened attention paid towards the prevalence of publication bias (e.g. Ioannidis 2005), meta-analysis—a set of statistical methods designed to illuminate patterns of similarity across studies—has now reached a favored position in many disciplines (e.g. Cumming 2012).”
BackgroundMethodHeart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962 · cited 5×
“Taken together, these methodological issues suggest that widely cited recommendations concerning minimum SFs and the benefits of R-peak interpolation (e.g. Task Force 1996a, Berntson et al 1997) may be due for a careful re-evaluation.”
BackgroundMethodInfluentialRank transformations as a bridge between parametric and nonparametric statistics
Conover, W. J., & Iman, R. L. (1981) · The American Statistician · doi:10.1080/00031305.1981.10479327 · Cited by 3,922 · cited 1×
“Another option utilizes a rank-based (nonparametric) test (for an overview, see Conover and Iman 1981), eliminating the need for any data transformations; for example, the Mann–Whitney–Wilcoxon U-test.”
MethodThayer, J. F., Åhs, F., Fredrikson, M., Sollers, J. J., & Wager, T. D. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2011.11.009 · Cited by 3,224 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundSelf-citationHeart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820 · cited 2×
“The above issues are further compounded when turning to the broader HRV literature, in which a highly heterogeneous set of SF values may be observed—a decade or more after the recommendations of Task Force (1996a, 1996b) and Berntson et al (1997) were published (table 2).”
BackgroundStatistical methods in psychology journals: Guidelines and explanations.
Wilkinson, L., & Task Force on Statistical Inference (1999) · American Psychologist · doi:10.1037/0003-066x.54.8.594 · Cited by 2,791 · cited 1×
“…from the PTBDB database used for the main set of experiments in this paper; thus, all processing steps (SF downsampling, R-peak extraction, HRV measure calculation) are identical to the steps outlined in section 2.2–2.5. advocated across numerous scientific domains; e.g. Kirk 1996, Wilkinson 1999).”
MethodInfluentialA review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
(2011) · Cited by 2,025
Ruxton, G. D. (2006) · Behavioral Ecology · doi:10.1093/beheco/ark016 · Cited by 1,988 · cited 1×
“For sake of comparison and completeness, both a t-test (Matlab’s ttest2.m applying the Welch– Satterthwaite correction for unequal variances; see Ruxton 2006) and a U-test (Matlab’s ranksum.m, on the original values) were performed.”
MethodPractical significance: a concept whose time has come
Kirk, R. E. (1996) · Educational and Psychological Measurement · doi:10.1177/0013164496056005002 · Cited by 1,778 · cited 1×
“…from the PTBDB database used for the main set of experiments in this paper; thus, all processing steps (SF downsampling, R-peak extraction, HRV measure calculation) are identical to the steps outlined in section 2.2–2.5. advocated across numerous scientific domains; e.g. Kirk 1996, Wilkinson 1999).”
MethodInfluentialHeart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290 · cited 1×
“…in the literature and often reported as showing high correlations with other measures which index rapid RR interval changes (such as RMSSD and HFau; e.g. Task Force 1996a, Kleiger et al 2005, Thayer and Fischer 2009, Smith et al 2013b), its statistical properties imply some important caveats.”
BackgroundKemp, A. H., Quintana, D. S., Gray, M. A., Felmingham, K. L., Brown, K., & Gatt, J. M. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2009.12.012 · Cited by 1,286 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242 · cited 3×
“Bandpass filtering of an ECG is typically performed prior to R-peak detection (e.g. Kohler et al 2002).”
MethodInfluentialA dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224 · cited 1×
“We also note that we opted not to use simulated ECGs (e.g. as are available using the compelling and comprehensive ECGSYN model proposed by McSharry and colleagues (McSharry et al 2003, McSharry and Clifford 2006).”
MethodFree, C., Phillips, G., Watson, L., Galli, L., Felix, L., Edwards, P., Patel, V., & Haines, A. (2013) · PLoS Medicine · doi:10.1371/journal.pmed.1001363 · Cited by 1,187 · cited 1×
“…through the use of components (e.g. low-profile external sensors; Patel et al 2012) that interface directly with the smartphone already in a patient’s pocket (e.g. Boulos et al 2011, Kay 2011, Free et al 2013) comes important considerations about system resources (e.g. Tarkoma et al 2014).”
BackgroundAn advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Fay, M. P., & Proschan, M. A. (2010) · Statistics Surveys · doi:10.1214/09-ss051 · Cited by 1,118 · cited 1×
“…not only to differences in distribution location (i.e. the median rank of each sample), but also to differences in distribution shape (Hart 2001); it is also more powerful than a t-test under a variety of non-normal distributional assumptions (e.g. Blair and Higgins 1980, Fay and Proschan 2010).”
BackgroundBoulos, M., Wheeler, S., Tavares, C., & Jones, R. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-24 · Cited by 1,071 · cited 1×
“…through the use of components (e.g. low-profile external sensors; Patel et al 2012) that interface directly with the smartphone already in a patient’s pocket (e.g. Boulos et al 2011, Kay 2011, Free et al 2013) comes important considerations about system resources (e.g. Tarkoma et al 2014).”
BackgroundAnxiety Disorders are Associated with Reduced Heart Rate Variability: A Meta-Analysis
Chalmers, J. A., Quintana, D. S., Abbott, M. J.-A., & Kemp, A. H. (2014) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2014.00080 · Cited by 1,067
Vasey, M. W., & Thayer, J. F. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00324.x · Cited by 1,063 · cited 1×
“…in-depth discussions of FPR in the context of psychophysiology have been largely restricted to techniques designed to maintain a valid familywise error rate when performing multiple comparisons within the context of repeated-measures analysis of variance (e.g. Jennings 1987, Vasey and Thayer 1987).”
MethodSelf-citationDo existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability
Brennan, M., Palaniswami, M., & Kamen, P. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959330 · Cited by 1,044 · cited 2×
“SD1 and SD2 were not examined in Schroeder et al (2004), but would be expected to show similar performance given their close mathematical relationship to SDSD and SDNN (Brennan et al 2001).”
BackgroundA comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“Artifacts (outliers) in an RR interval series can arise from several sources (e.g. Friesen et al 1990).”
BackgroundNUNAN, D., SANDERCOCK, G. R. H., & BRODIE, D. A. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02841.x · Cited by 874
Dekker, J. M., Crow, R. S., Folsom, A. R., Hannan, P. J., Liao, D., Swenne, C. A., & Schouten, E. G. (2000) · Circulation · doi:10.1161/01.cir.102.11.1239 · Cited by 859 · cited 1×
“…2 min’ accurately quantify the low-frequency component of HRV. Demonstrations of the diagnostic sensitivity of two-minute analysis of HRV in both the time-domain (e.g. Dekker et al 2000) and frequency-domain (e.g. Singh et al 1998, Hall et al 2004) are readily found in the literature.”
BackgroundAdvanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Nutzung der EKG-Signaldatenbank CARDIODAT der PTB über das Internet
Bousseljot, R., Kreiseler, D., & Schnabel, A. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.s1.317 · Cited by 623 · cited 1×
“For the present study, the PTB Diagnostic ECG Database (PTBDB; Bousseljot et al 1995) was selected.”
MethodMethods derived from nonlinear dynamics for analysing heart rate variability
Voss, A., Schulz, S., Schroeder, R., Baumert, M., & Caminal, P. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2008.0232 · Cited by 590 · cited 1×
“Another popular nonlinear HRV measure, detrended fluctuation analysis, is typically analyzed using windows of at least 8000 intervals, or roughly 2 h of continuous data (e.g. Huikuri et al 2003, Voss et al 2009).”
MethodMaser, R. E., Mitchell, B. D., Vinik, A. I., & Freeman, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1895 · Cited by 578 · cited 1×
“…results of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al…”
ResultSingh, J. P., Larson, M. G., Tsuji, H., Evans, J. C., O’Donnell, C. J., & Levy, D. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.293 · Cited by 559 · cited 1×
“…2 min’ accurately quantify the low-frequency component of HRV. Demonstrations of the diagnostic sensitivity of two-minute analysis of HRV in both the time-domain (e.g. Dekker et al 2000) and frequency-domain (e.g. Singh et al 1998, Hall et al 2004) are readily found in the literature.”
BackgroundMann-Whitney test is not just a test of medians: differences in spread can be important
Hart, A. (2001) · BMJ · doi:10.1136/bmj.323.7309.391 · Cited by 433 · cited 1×
“…is sensitive not only to differences in distribution location (i.e. the median rank of each sample), but also to differences in distribution shape (Hart 2001); it is also more powerful than a t-test under a variety of non-normal distributional assumptions (e.g. Blair and Higgins 1980, Fay and…”
BackgroundAn Approach to Artifact Identification: Application to Heart Period Data
Berntson, G. G., Quigley, K. S., Jang, J. F., & Boysen, S. T. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb01982.x · Cited by 392 · cited 3×
“A third caveat pertains to the exclusion of ECG records which yielded spurious R-peaks, missing R-peaks, or other potential outliers (as identified using the algorithm by Berntson et al 1990) across the entire set of SFEx values examined (i.e. relative to detected R-peaks in the ECGs at SFOr).”
BackgroundMethodInfluentialThe Fisher, Neyman-Pearson Theories of Testing Hypotheses: One Theory or Two?
Lehmann, E. L. (1993) · Journal of the American Statistical Association · doi:10.1080/01621459.1993.10476404 · Cited by 382
Acute Stress Affects Heart Rate Variability During Sleep
Hall, M., Vasko, R., Buysse, D., Ombao, H., Chen, Q., Cashmere, J. D., Kupfer, D., & Thayer, J. F. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000106884.58744.09 · Cited by 377 · cited 1×
“…2 min’ accurately quantify the low-frequency component of HRV. Demonstrations of the diagnostic sensitivity of two-minute analysis of HRV in both the time-domain (e.g. Dekker et al 2000) and frequency-domain (e.g. Singh et al 1998, Hall et al 2004) are readily found in the literature.”
BackgroundSelf-citationCould Fisher, Jeffreys and Neyman Have Agreed on Testing?
Berger, J. O. (2003) · Statistical Science · doi:10.1214/ss/1056397485 · Cited by 346 · cited 2×
“05); for some context, (see Lehmann 1993, Berger 2003). In this vein, a new question can be stated: ‘For a given population of individuals, if a particular HRV measure was obtained from an ECG recorded at a high SF (e.g. 1000 Hz) in one sample of subjects, and obtained from an ECG recorded at a lower SF (h Hz) in a di…”
BackgroundInfluentialCaby, B., Kieffer, S., de Saint Hubert, M., Cremer, G., & Macq, B. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-1 · Cited by 335
The reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundVanderlei, L. C. M., Silva, R. A., Pastre, C. M., Azevedo, F. M., & Godoy, M. F. (2008) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2008005000039 · Cited by 296 · cited 1×
“The combined advantages of easy and robust electrocardiogram (ECG) recording, affordable and valid ambulatory monitoring devices (e.g. Vanderlei et al 2008), and intuitive and comprehensive open-source analysis software (e.g. Tarvainen et al 2009) suggest that this growth will continue well into…”
BackgroundA systematic review and meta‐analysis of heart rate variability in epilepsy and antiepileptic drugs
Lotufo, P. A., Valiengo, L., Benseñor, I. M., & Brunoni, A. R. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2011.03361.x · Cited by 295 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundQuantifying Errors in Spectral Estimates of HRV Due to Beat Replacement and Resampling
Clifford, G. D., & Tarassenko, L. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844028 · Cited by 285 · cited 1×
“…well-known than FFT and AR approaches, the LS method of PSD estimation is considered superior to FFT and AR methods (for a detailed discussion, see Clifford and Tarassenko 2005), as it operates directly on the observed RR interval values and does not require their projection onto a regular time…”
MethodARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.
Kaufmann, T., Sütterlin, S., Schulz, S. M., & Vögele, C. (2011) · Behavior Research Methods · doi:10.3758/s13428-011-0107-7 · Cited by 284 · cited 1×
“…an RR series at SFOr (1000 Hz) that was free from any outliers (as detected by the widely used algorithm developed by Berntson et al 1990 and implemented by Kaufmann et al 2011), and (2) did not accrue any additional spurious or missed R-peaks relative to the R-peaks detected at SFOr at any SFEx.”
MethodReview and classification of variability analysis techniques with clinical applications
Bravi, A., Longtin, A., & Seely, A. J. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-90 · Cited by 265
The pNNx files: re-examining a widely used heart rate variability measure
Mietus, J. E., Peng, C.-K., Henry, I., Goldsmith, R. L., & Goldberger, A. L. (2002) · Heart · doi:10.1136/heart.88.4.378 · Cited by 262 · cited 2×
“A final exclusion was the ‘pNNx family’ of statistics (Mietus et al 2002): the percentage of RR intervals greater than x ms (typically, with x = 50).”
BackgroundVikman, S., Mäkikallio, T. H., Yli-Mäyry, S., Pikkujämsä, S., Koivisto, A.-M., Reinikainen, P., Airaksinen, K. E. J., & Huikuri, H. V. (1999) · Circulation · doi:10.1161/01.cir.100.20.2079 · Cited by 250 · cited 1×
“…recordings of HRV. Geometric measures (e.g. the HRV triangular index and the triangular interpolation of RR interval histogram) require at least 20 min (and ‘preferably’ 24 h, per TF96), as do entropy measures (e.g. approximate entropy and sample entropy; Hogue et al 1998, Vikman et al 1999).”
MethodSampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
Merri, M., Farden, D. C., Mottley, J. G., & Titlebaum, E. L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43621 · Cited by 248 · cited 2×
“Several studies investigated samples of fewer than five (Merri et al 1990, Pinna et al 1994, Riniolo and Porges 1997, Hejjel and Roth 2004, Bragge T ab le 1 .”
BackgroundResultEditorial Policy on Analyses of Variance With Repeated Measures
Jennings, J. R. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00320.x · Cited by 244 · cited 1×
“…in-depth discussions of FPR in the context of psychophysiology have been largely restricted to techniques designed to maintain a valid familywise error rate when performing multiple comparisons within the context of repeated-measures analysis of variance (e.g. Jennings 1987, Vasey and Thayer 1987).”
MethodTime-variant power spectrum analysis for the detection of transient episodes in HRV signal
Bianchi, A. M., Mainardi, L., Petrucci, E., Signorini, M. G., Mainardi, M., & Cerutti, S. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.212067 · Cited by 222 · cited 2×
“In a few further cases, a separate device was used to record the ECG at one or more SFEx (Bianchi et al 1993, Pinna et al 1994, Chellakumar et al 2005), introducing a possible confound (i.e. if device-induced measurement artifacts were present).”
MethodResultThe Fisher, Neyman-Peerson Theories of Testing Hypotheses: One Theory or Two?
Lehmann, E. L. (2012) · Selected Works of E. L. Lehmann · doi:10.1007/978-1-4614-1412-4_19 · Cited by 220 · cited 1×
“In frequentist statistical inference, the critical value of statistical tests (e.g. t-test, F-test, correlation, regression) is set a priori so as to control the expected rate at which false positives should occur; by convention, 5% (i.e. α = 0.05); for some context, (see Lehmann 1993, Berger 2003).”
InfluentialKubios HRV — A Software for Advanced Heart Rate Variability Analysis
Tarvainen, M. P., Niskanen, J. P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2009) · IFMBE Proceedings · doi:10.1007/978-3-540-89208-3_243 · Cited by 197 · cited 1×
“…advantages of easy and robust electrocardiogram (ECG) recording, affordable and valid ambulatory monitoring devices (e.g. Vanderlei et al 2008), and intuitive and comprehensive open-source analysis software (e.g. Tarvainen et al 2009) suggest that this growth will continue well into the future.”
BackgroundHogue, C. W., Domitrovich, P. P., Stein, P. K., Despotis, G. D., Re, L., Schuessler, R. B., Kleiger, R. E., & Rottman, J. N. (1998) · Circulation · doi:10.1161/01.cir.98.5.429 · Cited by 189 · cited 1×
“…recordings of HRV. Geometric measures (e.g. the HRV triangular index and the triangular interpolation of RR interval histogram) require at least 20 min (and ‘preferably’ 24 h, per TF96), as do entropy measures (e.g. approximate entropy and sample entropy; Hogue et al 1998, Vikman et al 1999).”
MethodDifferent Outcomes of the Wilcoxon—Mann—Whitney Test from Different Statistics Packages
Bergmann, R., Ludbrook, J., & Spooren, W. P. J. M. (2000) · The American Statistician · doi:10.1080/00031305.2000.10474513 · Cited by 177 · cited 2×
“This was not unexpected, due to the noncontinuous relationship between rank-based statistics and their ‘exact’ p-values (see Bergmann et al 2000).”
BackgroundMethodRepeatability of heart rate variability measures
Schroeder, E. B., Whitsel, E. A., Evans, G. W., Prineas, R. J., Chambless, L. E., & Heiss, G. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.04.004 · Cited by 170 · cited 2×
“Schroeder et al (2004) examined several HRV statistics (AVNN, SDNN, RMSSD, HFau, LFau, HFnu, and LFnu) derived from 2 min versus 6 min ECGs at 1000 Hz are highly-correlated (their table 5), and yield a similar breakdown of variance components (e.g. between-person, betweenvisit, within-visit) when…”
BackgroundMeasurement of heart rate variability by methods based on nonlinear dynamics
Huikuri, H. V., Mäkikallio, T. H., & Perkiömäki, J. (2003) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2003.09.021 · Cited by 170 · cited 1×
“Another popular nonlinear HRV measure, detrended fluctuation analysis, is typically analyzed using windows of at least 8000 intervals, or roughly 2 h of continuous data (e.g. Huikuri et al 2003, Voss et al 2009).”
MethodThayer, J. F., & Fischer, J. E. (2009) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2008.02023.x · Cited by 141 · cited 1×
“…in the literature and often reported as showing high correlations with other measures which index rapid RR interval changes (such as RMSSD and HFau; e.g. Task Force 1996a, Kleiger et al 2005, Thayer and Fischer 2009, Smith et al 2013b), its statistical properties imply some important caveats.”
BackgroundSelf-citationTak, L. M., Riese, H., de Bock, G. H., Andiappan, M., Kok, I. C., & Rosmalen, J. G. M. (2009) · Biological Psychology · doi:10.1016/j.biopsycho.2009.05.002 · Cited by 137 · cited 1×
“…of the meta-analysis is thus an open question, but one that has not been addressed by any of the several recent meta-analyses examining HRV (Maser et al 2003, Sandercock et al 2005, Tak et al 2009, Kemp et al 2010, Nunan et al 2010, Lotufo et al 2012, Thayer et al 2012, Chalmers et al 2014).”
BackgroundWhy Most Published Research Findings Are False: Author's Reply to Goodman and Greenland
Ioannidis, J. P. A. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040215 · Cited by 121
Smartphone Energy Consumption: Modeling and Optimization
Tarkoma, S., Siekkinen, M., Lagerspetz, E., & Xiao, Y. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107326279 · Cited by 96 · cited 1×
“…through the use of components (e.g. low-profile external sensors; Patel et al 2012) that interface directly with the smartphone already in a patient’s pocket (e.g. Boulos et al 2011, Kay 2011, Free et al 2013) comes important considerations about system resources (e.g. Tarkoma et al 2014).”
BackgroundDifferent Outcomes of the Wilcoxon-Mann-Whitney Test from Different Statistics Packages
Bergmann, R., Ludbrook, J., & Spooren, W. P. J. M. (2000) · The American Statistician · doi:10.2307/2685616 · Cited by 93
Hejjel, L., & Roth, E. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/6/006 · Cited by 84 · cited 4×
“Several studies investigated samples of fewer than five (Merri et al 1990, Pinna et al 1994, Riniolo and Porges 1997, Hejjel and Roth 2004, Bragge R J Ellis et al Physiol. Meas. 36 (2015) 1827”
BackgroundInfluentialThe effect of missing RR-interval data on heart rate variability analysis in the frequency domain
Kim, K. K., Kim, J. S., Lim, Y. G., & Park, K. S. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/10/005 · Cited by 82 · cited 1×
“A disturbance in the cardiac electrical rhythm (ectopic beats), electrical noise during ECG recording, or errors during QRS detection itself can compromise the accuracy of HRV measures (e.g. Kim et al 2007, 2009).”
BackgroundHeart rate variability indices for very short-term (30 beat) analysis. Part 1: survey and toolbox
Smith, A.-L., Owen, H., & Reynolds, K. J. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9471-4 · Cited by 76 · cited 2×
“(Thorough explanations of these HRV measures are available elsewhere; e.g. TF96; Rajendra Acharya et al 2006, Bravi et al 2011, Tarvainen and Niskanen 2012, Smith et al 2013a).”
BackgroundTesting for robustness in Monte Carlo studies.
Serlin, R. C. (2000) · Psychological Methods · doi:10.1037//1082-989x.5.2.230 · Cited by 71 · cited 1×
“(For a theoretical and practical overview of Monte Carlo–based evaluations of FPR, see Serlin 2000).”
BackgroundImprovement of resolution in measurement of electrocardiogram RR intervals by interpolation
Daskalov, I., & Christov, I. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(96)00067-7 · Cited by 70
Ziemssen, T., Gasch, J., & Ruediger, H. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9117-0 · Cited by 67 · cited 1×
“…analysis include repeated-measures analysis of variance (ANOVA; Pinna et al 1994, Chellakumar et al 2005, Bhatia et al 2010); Bland–Altman plots (Ziemssen et al 2008); and signed error (either in original units or as a percentage; Abboud and Barnea 1995, Daskalov and Christov 1997, Dinh et al…”
MethodData transforms for spectral analyses of heart rate variability.
Ellis, R. J., Sollers, J. J., Edelstein, E. A., & Thayer, J. F. (2008) · PubMed · Cited by 62
Self-citationHeart rate variability indices for very short-term (30 beat) analysis. Part 2: validation
Smith, A.-L., Owen, H., & Reynolds, K. J. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9473-2 · Cited by 62
RINIOLO, T., & PORGES, S. W. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb01748.x · Cited by 59 · cited 1×
“Several studies investigated samples of fewer than five (Merri et al 1990, Pinna et al 1994, Riniolo and Porges 1997, Hejjel and Roth 2004, Bragge T ab le 1 .”
BackgroundDinh, H.-H., Kumar, D., Pah, N. D., & Burton, P. C. M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1020593 · Cited by 57
Power reduction by varying sampling rate
Dieter, W. R., Datta, S., & Kai, W. K. (2005) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1145/1077603.1077658 · Cited by 56 · cited 1×
“However, although halving the sampling frequency (clock rate) of a transistor cuts its power consumption in half (e.g. Dieter et al 2005), it may also decrease the quality recorded physiological signal, thereby adding a source of error during HRV outcome measure calculation.”
BackgroundPinna, G. D., Maestri, R., Cesare, A. D., Colombo, R., & Minuco, G. (1994) · Physiological Measurement · doi:10.1088/0967-3334/15/2/006 · Cited by 49 · cited 5×
“In a few further cases, a separate device was used to record the ECG at one or more SFEx (Bianchi et al 1993, Pinna et al 1994, Chellakumar et al 2005), introducing a possible confound (i.e. if device-induced measurement artifacts were present).”
BackgroundMethodInfluentialThe Power of t and Wilcoxon Statistics: A Comparison
Blair, R. C., & Higgins, J. J. (1980) · Evaluation Review · doi:10.1177/0193841x8000400506 · Cited by 46 · cited 1×
“…not only to differences in distribution location (i.e. the median rank of each sample), but also to differences in distribution shape (Hart 2001); it is also more powerful than a t-test under a variety of non-normal distributional assumptions (e.g. Blair and Higgins 1980, Fay and Proschan 2010).”
BackgroundEffect of missing RR-interval data on heart rate variability analysis in the time domain
Kim, K. K., Lim, Y. G., Kim, J. S., & Park, K. S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/12/003 · Cited by 38 · cited 1×
“A disturbance in the cardiac electrical rhythm (ectopic beats), electrical noise during ECG recording, or errors during QRS detection itself can compromise the accuracy of HRV measures (e.g. Kim et al 2007, 2009).”
BackgroundGarcia-Gonzalez, M. A., Fernández-Chimeno, M., & Ramos-Castro, J. J. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/008 · Cited by 32 · cited 2×
“Some studies added stochastic temporal error to the location of R-peaks detected at SFOr (Garcia-Gonzalez et al 2004, Hejjel and Roth 2004).”
BackgroundGarcia-Gonzalez, M. A., Fernández-Chimeno, M., & Ramos-Castro, J. J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005951 · Cited by 31 · cited 1×
“…2005, Bhatia et al 2010); Bland–Altman plots (Ziemssen et al 2008); and signed error (either in original units or as a percentage; Abboud and Barnea 1995, Daskalov and Christov 1997, Dinh et al 2001, Hejjel and Roth 2004, García-González et al 2009) or normalized bias (Garcia-Gonzalez et al 2004).”
BackgroundBhatia, V. N., Rarick, K. R., & Stauss, H. M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/009 · Cited by 29 · cited 3×
“First, a piecewise cubic spline (e.g. Daskalov and Christov 1997) was fit to each downsampled ECG (using Matlab’s spline.m), and resampled at 1000 Hz (as in Daskalov and Christov 1997, Bhatia et al 2010).”
BackgroundMethodRiniolo, T. C., & Porges, S. W. (2000) · Psychophysiology · doi:10.1111/1469-8986.3710021 · Cited by 28 · cited 1×
“Because distributions of HRV values vary widely in terms of their (non)normality (e.g. positively skewed SDSD, RMSSD, LFau, and HFau), assessment of between-sample differences typically follow one of two analysis options (see Riniolo and Porges 2000, Ellis et al 2008).”
BackgroundAbboud, S., & Barnea, O. (2002) · Computers in cardiology · doi:10.1109/cic.1995.482685 · Cited by 27 · cited 2×
“…s; k ‘i nfi ni te -r es ol ut io n’ R R in te rv al s er ie s w er e ge ne ra te d by a dd in g un if or m n oi se to o bs er ve d R -p ea ks . et al 2005) or ten (Abboud and Barnea 1995, Chellakumar et al 2005) subjects from the same population (i.e. either healthy control or a patient…”
BackgroundHeart rate variability: comparison among devices with different temporal resolutions
Chellakumar, P. J., Brumfield, A., Kunderu, K., & Schopper, A. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/008 · Cited by 18
High-resolution QRS fiducial point corrections in sparsely sampled ECG recordings
Bragge, T., Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/013 · Cited by 16
Interpolation technique for extracting features from ECG signals sampled at low sampling rates
Castiglioni, P., Piccini, L., & Rienzo, M. D. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291197 · Cited by 11 · cited 2×
“Only a few studies have performed a true decimation of the ECG digitized at SFOr (Daskalov and Christov 1997, Castiglioni et al 2003, Bragge et al 2005, Bhatia et al 2010).”
BackgroundCimalla, P., Graf, D., Duscha, P., Meyer, T., Kuß, J., Steinmeier, R., Koch, E., & Morgenstern, U. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_343 · Cited by 7
Power reduction by varying sampling rate
Dieter, W. R., Datta, S., & Kai, W. K. (2005) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1109/lpe.2005.195519 · Cited by 6
The effect of electrocardiographic lead choice on RR time series
Garcia-Gonzalez, M. A., Ramos-Castro, J. J., & Fernández-Chimeno, M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090546 · Cited by 4 · cited 1×
“Because ECG lead configuration can induce systematic effects on HRV (García-González et al 2011), only lead II ECGs were examined.”
Background
Research works printed but not linked: 5
- Abboud S, 1995, Comput. Cardiol., 461
- Castiglioni P, 2003, Comput. Cardiol., 481
- Ellis R J, 2008, Biomed. Sci. Instrum., 44, 392
- Kay M, 2011, World Health Organ.
- 10.1037/1082-989x.5.2.230 · doi:10.1037/1082-989x.5.2.230 · Paper page
Cited by
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“…to enhance the R-wave fiducial point) was applied prior to HRV calculation, sampling rate could even be lower than 100 Hz, and without R-peak interpolation the analysis could be considered as reliable down to 125 Hz for all measures, and far lower in case of specific measures (Ellis et al., 2015).”
MethodSelf-citationErshad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N.-I., Rao, Z., Guevara, R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17619-1 · Cited by 355
Quigley, K. S., Gianaros, P. J., Norman, G. J., Jennings, J. R., Berntson, G. G., & de Geus, E. J. C. (2024) · Psychophysiology · doi:10.1111/psyp.14604 · Cited by 225
Electrocardiogram Sampling Frequency Range Acceptable for Heart Rate Variability Analysis
Kwon, O., Jeong, J., Kim, H. B., Kwon, I. H., Park, S. Y., Kim, J. E., & Choi, Y. (2018) · Healthcare Informatics Research · doi:10.4258/hir.2018.24.3.198 · Cited by 180
“HRV is known to be associated with the interplay of the sympathetic and parasympathetic autonomic nervous systems [15].”
BackgroundMethodHidden Signals—The History and Methods of Heart Rate Variability
Ernst, G. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00265 · Cited by 201
“A recent exploration described stable measures at sampling rates of 125 Hz or lower (88).”
Background
Metadata
- Authors
- Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y.
- Affiliations
- National University of Singapore (SG)
- Fudan University (CN)
- The Ohio State University (US)
- Corresponding author
- Wang, Ye
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2015-08-03
- Volume
- 36
- Issue
- 9
- Pages
- 1827-1852
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2469606930
- Semantic Scholar
- 6fda1efdcc541bb6c50e23ddac2d546c8ac26c99
- Cited by
- 85
- References
- 89
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 12 · 2023: 11 · 2022: 10 · 2021: 4 · 2020: 11 · 2019: 5 · 2018: 10 · 2017: 8 · 2016: 6
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Singapore Ministry of Education (R-252-000-516-112)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, R-peak detection, false positive rate, statistical validity, time-domain HRV measures, frequency-domain HRV measures, cross-study comparability, mobile health, meta-analysis
- MeSH terms
- Adolescent, Adult, Aged, Electrocardiography, False Positive Reactions, Heart Rate, Humans, Middle Aged, Monte Carlo Method, Signal Processing, Computer-Assisted, Internet, Young Adult, Datasets as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.