Automatic bearing fault diagnosis of permanent magnet synchronous generators in wind turbines subjected to noise interference
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
An automatic bearing fault diagnosis method is proposed for permanent magnet synchronous generators (PMSGs), which are widely installed in wind turbines subjected to low rotating speeds, speed fluctuations, and electrical device noise interferences. The mechanical rotating angle curve is first extracted from the phase current of a PMSG by sequentially applying a series of algorithms. The synchronous sampled vibration signal of the fault bearing is then resampled in the angular domain according to the obtained rotating phase information. Considering that the resampled vibration signal is still overwhelmed by heavy background noise, an adaptive stochastic resonance filter is applied to the resampled signal to enhance the fault indicator and facilitate bearing fault identification. Two types of fault bearings with different fault sizes in a PMSG test rig are subjected to experiments to test the effectiveness of the proposed method. The proposed method is fully automated and thus shows potential for convenient, highly efficient and in situ bearing fault diagnosis for wind turbines subjected to harsh environments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most studies are carried out using physically damaged bearings by cutting, drilling or electrically engraved pitting of the component [117], [120], [121], [125], [127], [129], [138]- [140].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [117]
Citations
Cites
Digital Signal Processing : A Computer-Based Approach
Mitra, S. (1997) · Cited by 2,115
Wavelets for fault diagnosis of rotary machines: A review with applications
Yan, R., Gao, R. X., & Chen, X. (2014) · Signal Processing · doi:10.1016/j.sigpro.2013.04.015 · Cited by 1,446 · cited 1×
“Second, at a constant rotation speed, established techniques, such as fast Fourier transform (FFT) and the demodulated resonance technique, can be used to analyze the bearing signal in the frequency domain in order to obtain the fault characteristic frequency (FCF) for fault identification [19].”
MethodComputing the discrete-time "analytic" signal via FFT
Marple, L. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.782222 · Cited by 753
A review on small scale wind turbines
Tummala, A., Velamati, R. K., Sinha, D. K., Indraja, V., & Krishna, V. H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.027 · Cited by 591
Immovilli, F., Bellini, A., Rubini, R., & Tassoni, C. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049623 · Cited by 382
A review of wind turbine bearing condition monitoring: State of the art and challenges
de Azevedo, H. D. M., Araújo, A. M., & Bouchonneau, N. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.032 · Cited by 382
Chen, J., Pan, J., Li, Z., Zi, Y., & Chen, X. (2016) · Renewable Energy · doi:10.1016/j.renene.2015.12.010 · Cited by 361
Planetary gearbox fault diagnosis using an adaptive stochastic resonance method
Lei, Y., Han, D., Lin, J., & He, Z. (2013) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.06.021 · Cited by 299 · cited 1×
“Given this, the computation time of ASR could be reduced by using some intelligent algorithms such as a genetic algorithm [29], fish swarm algorithm [35] or ant colony algorithm [36].”
MethodQiao, Z., Lei, Y., Lin, J., & Jia, F. (2017) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2016.08.030 · Cited by 268
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212 · cited 1×
“PMSGs have simple mechanical structures, exhibit high reliability, and are thus often installed on wind turbines [3, 4].”
Background
Cited by
Liu, Z., & Zhang, L. (2020) · Measurement · doi:10.1016/j.measurement.2019.107002 · Cited by 535
A review of stochastic resonance in rotating machine fault detection
Lu, S., He, Q., & Wang, J. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.032 · Cited by 382
Self-citationFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“However, the influence of the supply voltage frequency changes is a little greater for EPVA than in the case of DWT of current ENV.”
BackgroundMethodInfluentialApplications of stochastic resonance to machinery fault detection: A review and tutorial
Qiao, Z., Lei, Y., & Li, N. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.12.032 · Cited by 308
Lu, S., Yan, R., Liu, Y., & Wang, Q. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2902806 · Cited by 271
“ing to the estimated speed for TOT [82].”
BackgroundSelf-citation
Metadata
- Authors
- Guo, J., Lu, S., Zhai, C., & He, Q.
- Affiliations
- Anhui University (CN)
- University of Science and Technology of China (CN)
- Corresponding author
- Lu, Siliang
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2018-01-09
- Volume
- 29
- Issue
- 2
- Pages
- 025002
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2764085635
- Cited by
- 25
- References
- 38
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 5 · 2019: 8 · 2018: 1
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Measurement Science and Technology (publishedVersion)
- Funders
- National Natural Science Foundation of China (51605002)
- Natural Science Foundation of Anhui Province (1608085QE110)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Mechanical Engineering › Gear and Bearing Dynamics Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- bearing fault diagnosis, permanent magnet synchronous generator, wind turbines, noise interference, phase current, low-speed operation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic bearing fault diagnosis of permanent magnet synchronous generators in wind turbines subjected to noise interference. https://app.cochat.ai/papers/10.1088/1361-6501/aa92d6
- The paper
- Guo, J., Lu, S., Zhai, C., & He, Q. (2018). Automatic bearing fault diagnosis of permanent magnet synchronous generators in wind turbines subjected to noise interference. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aa92d6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.