Robust sound speed estimation for ultrasound-based hepatic steatosis assessment
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Hepatic steatosis is a common condition, the prevalence of which is increasing along with non-alcoholic fatty liver disease (NAFLD).Currently, the most accurate noninvasive imaging method for diagnosing and quantifying hepatic steatosis is MRI, which estimates the proton-density fat fraction (PDFF) as a measure of fractional fat content.However, MRI suffers several limitations including cost, contra-indications and poor availability.Although conventional ultrasound is widely used by radiologists for hepatic steatosis assessment, it remains qualitative and operator dependent.Interestingly, the speed of sound within soft tissues is known to vary slightly from muscle (1.575 mm • µs -1 ) to fat (1.450 mm • µs -1 ).Building upon this fact, steatosis could affect liver sound speed when the fat content increases.The main objectives of this study are to propose a robust method for sound speed estimation (SSE) locally in
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106
Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study
Foucher, J. (2006) · Gut · doi:10.1136/gut.2005.069153 · Cited by 1,284
Sasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
Sumida, Y. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i2.475 · Cited by 689
Validity of real time ultrasound in the diagnosis of hepatic steatosis: A prospective study
Dasarathy, S., Dasarathy, J., Khiyami, A., Joseph, R., Lopez, R., & McCullough, A. J. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.09.001 · Cited by 656
Synthetic aperture imaging for small scale systems
Karaman, M., Li, P.-C., & O'Donnell, M. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.384453 · Cited by 575
Histopathology of nonalcoholic fatty liver disease
Brunt, E. M. (2010) · World Journal of Gastroenterology · doi:10.3748/wjg.v16.i42.5286 · Cited by 449 · cited 8×
“Impact of the aberration correction on the SSE. Results are presented for two patients. (a) Correlation maps at the first iteration. (b) Correlation maps after 10 iterations of the correction aberration algorithm. (c) Evolution of the area under the coherence function curve throughout iterations. (d) Conventional B-mo…”
BackgroundMethodInfluentialShort-lag spatial coherence of backscattered echoes: imaging characteristics
Lediju, M. A., Trahey, G. E., Byram, B. C., & Dahl, J. J. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1957 · Cited by 445
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Self-citationHepatic Steatosis: Quantification by Proton Density Fat Fraction with MR Imaging versus Liver Biopsy
Idilman, I. S., Aniktar, H., Idilman, R., Kabacam, G., Savas, B., Elhan, A., Celik, A., Bahar, K., & Karcaaltincaba, M. (2013) · Radiology · doi:10.1148/radiol.13121360 · Cited by 389
Foucher, J., Cast??ra, L., Bernard, P.-H., Adhoute, X., Laharie, D., Bertet, J., Couzigou, P., & de L??dinghen, V. (2006) · European Journal of Gastroenterology & Hepatology · doi:10.1097/00042737-200604000-00015 · Cited by 382
Sonography of Diffuse Liver Disease
Tchelepi, H., Ralls, P. W., Radin, R., & Grant, E. G. (2002) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2002.21.9.1023 · Cited by 327
Diagnosis of Nonalcoholic Fatty Liver Disease: Invasive versus Noninvasive
Wieckowska, A., & Feldstein, A. (2008) · Seminars in Liver Disease · doi:10.1055/s-0028-1091983 · Cited by 300
Deffieux, T., Gennisson, J.-L., Bousquet, L., Corouge, M., Cosconea, S., Amroun, D., Tripon, S., Terris, B., Mallet, V., Sogni, P., et al. (2015) · Journal of Hepatology · doi:10.1016/j.jhep.2014.09.020 · Cited by 255 · cited 1×
“Ultrasonic imaging has been explored for many years for its ability to detect and characterize liver disease and is highly accurate to diagnose liver cirrhosis (Tchelepi et al 2002, Mishra and Younossi 2007, Deffieux et al 2015). Yet, current conventional ultrasonic techniques do not allow for quantification of the de…”
Self-citationNon-invasive means of measuring hepatic fat content
Mehta, S. R., Thomas, E. L., Bell, J. D., Johnston, D. G., & Taylor-Robinson, S. D. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.3476 · Cited by 255
Lin, S. C., Heba, E., Wolfson, T., Ang, B., Gamst, A., Han, A., Erdman, J. W., O’Brien, W. D., Andre, M. P., Sirlin, C. B., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.11.027 · Cited by 254 · cited 2×
“Where [ ] T T 1 2 is the temporal window centered on the focal time and Si is the time-delayed signal received on transducer i . When the ultrasonic wave is focused on a point-like target in the medium, the coherence function is equal to 1 all along the array. In the case of a homogeneous medium made of randomly distr…”
BackgroundInfluentialAbdominal Ultrasound for Diagnosis of Nonalcoholic Fatty Liver Disease (NAFLD)
Mishra, P., & Younossi, Z. M. (2007) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2007.01520.x · Cited by 207
Xia, M., Yan, H., He, W., Li, X., Li, C., Yao, X., Li, R., Zeng, M., & Gao, X. (2012) · Obesity · doi:10.1038/oby.2011.302 · Cited by 165
Fatty liver disease in severe obese patients: Diagnostic value of abdominal ultrasound
Almeida, A.-M. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.1415 · Cited by 135
Histologic Variation of Grade and Stage of Non-alcoholic Fatty Liver Disease in Liver Biopsies
Janiec, D. J., Jacobson, E. R., Freeth, A., Spaulding, L., & Blaszyk, H. (2005) · Obesity Surgery · doi:10.1381/0960892053723268 · Cited by 135
Quantification of the triglyceride fatty acid composition with 3.0 T MRI
Leporq, B., Lambert, S. A., Ronot, M., Vilgrain, V., & BEERS, B. E. V. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3175 · Cited by 79
Self-citationHepatic Steatosis: Assessment with Acoustic Structure Quantification of US Imaging
Son, J. Y., Lee, J. Y., Yi, N., Lee, K., Suh, K., Kim, K. G., Lee, J. M., Han, J. K., & Choi, B. I. (2015) · Radiology · doi:10.1148/radiol.2015141779 · Cited by 76
Chassat, F. (1989) · Journal of Optics · doi:10.1088/0150-536x/20/1/002 · Cited by 72
Clinical Sound Speed Measurement in Liver and Spleen in Vivo
Chen, C., Robinson, D. E., Wilson, L. S., Griffiths, K. A., Manoharan, A., & Doust, B. D. (1987) · Ultrasonic Imaging · doi:10.1177/016173468700900401 · Cited by 61
Donor Selection for Adult-to-Adult Living Donor Liver Transplantation: Well Begun Is Half Done
Sharma, A. K., Ashworth, A., Behnke, M. K., COTTERELL, A. H., Posner, M. P., & Fisher, R. A. (2012) · Transplantation · doi:10.1097/tp.0b013e318274aba1 · Cited by 59
A motion-based approach to abdominal clutter reduction
Lediju, M. A., Pihl, M. J., Hsu, S. J., Dahl, J., Gallippi, C. M., & Trahey, G. E. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1331 · Cited by 51
Synthetic focus imaging using partial datasets
Cooley, & Робинсон (1994) · doi:10.1109/ultsym.1994.401884 · Cited by 48
Cited by
Ultrasound-based techniques for the diagnosis of liver steatosis
Ferraioli, G., & Monteiro, L. B. S. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i40.6053 · Cited by 506
So you think you can DAS? A viewpoint on delay-and-sum beamforming
Perrot, V., Polichetti, M., Varray, F., & Garcia, D. (2021) · Ultrasonics · doi:10.1016/j.ultras.2020.106309 · Cited by 377
Pirmoazen, A. M., Khurana, A., El Kaffas, A., & Kamaya, A. (2020) · Theranostics · doi:10.7150/thno.40249 · Cited by 165
Quantification of Liver Fat Content with Ultrasound: A WFUMB Position Paper
Ferraioli, G., Berzigotti, A., Barr, R. G., Choi, B. I., Cui, X. W., Dong, Y., Gilja, O. H., Lee, J. Y., Lee, D. H., Moriyasu, F., et al. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.06.002 · Cited by 159
Jang, W., & Song, J. S. (2023) · Diagnostics · doi:10.3390/diagnostics13111852 · Cited by 55
Metadata
- Authors
- Imbault, M., Faccinetto, A., Osmanski, B.-F., Tissier, A., Deffieux, T., Gennisson, J.-L., Vilgrain, V., & Tanter, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2017-04-05
- Volume
- 62
- Issue
- 9
- Pages
- 3582-3598
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2591130690
- Cited by
- 181
- References
- 27
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.