Real-time intrafraction motion monitoring in external beam radiotherapy
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to ‘see what we treat, as we treat’ and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
(2014) · Climate Change 2013 – The Physical Science Basis · doi:10.1017/cbo9781107415324.004 · Cited by 23,880
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Self-citationHandbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379 · cited 3×
“The high monitoring rate of the RTRT system has permitted to extensively study tumour motion in various anatomical sites (Seppenwoolde et al 2002, Kitamura et al 2003, 2002, Ahn et al 2004, Hashimoto et al 2005, Shirato et al 2007, Kinoshita et al 2008).”
Background4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287
Bentzen, S. M., Constine, L. S., Deasy, J. O., Eisbruch, A., Jackson, A., Marks, L. B., Ten Haken, R. K., & Yorke, E. D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.09.040 · Cited by 1,257
Onishi, H., Shirato, H., Nagata, Y., Hiraoka, M., Fujino, M., 五味, 光., Niibe, Y., Karasawa, K., Hayakawa, K., Takai, Y., et al. (2007) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318074de34 · Cited by 989
The ViewRay System: Magnetic Resonance–Guided and Controlled Radiotherapy
Mutic, S., & Dempsey, J. F. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.008 · Cited by 915
The use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
The Cyberknife: A Frameless Robotic System for Radiosurgery
Adler Jr., J. R., Chang, S. D., Murphy, M. J., Doty, J., Geis, P., & Hancock, S. L. (1997) · Stereotactic and Functional Neurosurgery · doi:10.1159/000099863 · Cited by 671
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23639 · Cited by 606 · cited 1×
“Should neither be acceptable, parallel imaging techniques can be deployed to reconstruct undersampled k-space data using multiple independent coils to record the subject’s MR signal (Deshmane et al 2012).”
BackgroundExecutive Functioning in Highly Talented Soccer Players
Verburgh, L., Scherder, E. J. A., van Lange, P. A. M., & Oosterlaan, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091254 · Cited by 560
Raaymakers, B. W., Jürgenliemk-Schulz, I. M., Bol, G. H., Glitzner, M., Kotte, A. N. T. J., van Asselen, B., de Boer, J. C. J., Bluemink, J. J., Hackett, S. L., Moerland, M. A., et al. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9517 · Cited by 541
Image-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496 · cited 4×
“and has opened “many doors for exploration” (Jaffray 2012).”
BackgroundInfluentialKupelian, P., Willoughby, T., Mahadevan, A., Djemil, T., Weinstein, G., Jani, S., Enke, C., Solberg, T., Flores, N., Liu, D., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.10.026 · Cited by 490 · cited 2×
“Calypso was first used clinically in the prostate (Willoughby et al 2006b), where the ability of continuous monitoring without ionizing radiation has allowed systematic investigation of motion patterns (Kupelian et al 2007).”
MethodResultThe Magnetic Resonance Imaging–Linac System
Lagendijk, J. J. W., Raaymakers, B. W., & van Vulpen, M. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.009 · Cited by 464 · cited 1×
“There are currently two commercially available MR-guided treatment systems: the ViewRay MRIdian and the Elekta Unity system (figure 2(d)) (Raaymakers et al 2009, Lagendijk et al 2014, Mutic and Dempsey 2014, Mutic et al 2016).”
MethodRespiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457 · cited 1×
“If at all, moving targets are treated in breath-hold or with gating (Minohara et al 2000, Bert et al 2009, He et al 2014, Zhang et al 2015, Yamada et al 2016).”
BackgroundKing, C. R., Brooks, J. D., Gill, H. S., & Presti, J. C. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.11.054 · Cited by 428
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385 · cited 3×
“Several studies have investigated the correlation between breathing and target motion, the stability of that correlation, ECMs of different forms, and update strategies (McClelland et al 2013).”
BackgroundSelf-citationThe Australian Magnetic Resonance Imaging–Linac Program
Keall, P. J., Barton, M., & Crozier, S. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.015 · Cited by 351
Self-citationBuch, K., Peters, T., Nawroth, T., Sänger, M., Schmidberger, H., & Langguth, P. (2012) · Radiation Oncology · doi:10.1186/1748-717x-7-1 · Cited by 344
Hoogeman, M., Prévost, J.-B., Nuyttens, J., Pöll, J., Levendag, P., & Heijmen, B. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.12.041 · Cited by 327 · cited 2×
“Fully integrated systems such as robotic linear accelerators (linac) and gimbal steered linacs with imaging suites were specifically designed to combine motion monitoring with mitigation by dynamic tumour tracking and are now routinely used (Hoogeman et al 2009, Depuydt et al 2014).”
Method4D MR imaging of respiratory organ motion and its variability
Siebenthal, M. V., Székely, G., Gamper, U., Boesiger, P., Lomax, A., & Cattin, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/001 · Cited by 324 · cited 1×
“One drawback is that such datasets can take a long time to acquire and process (Von Siebenthal et al 2007).”
BackgroundCorrelation of lung tumor motion with external surrogate indicators of respiration
Hoisak, J. D. P., Sixel, K. E., Tirona, R., Cheung, P. C. F., & Pignol, J.-P. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.07.681 · Cited by 318
Motion in radiotherapy: particle therapy
Bert, C., & Durante, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/r01 · Cited by 315
Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications
Acharya, S., Fischer-Valuck, B. W., Kashani, R., Parikh, P., Yang, D., Zhao, T., Green, O., Wooten, O., Li, H. H., Hu, Y., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.10.015 · Cited by 302 · cited 1×
“Results from initial clinical trials (Acharya et al 2016, Henke et al 2018) and further research studies will provide much needed experience about the potential of MR imaging for intrafractional motion monitoring.”
Seppenwoolde, Y., Berbeco, R. I., Nishioka, S., Shirato, H., & Heijmen, B. (2007) · Medical Physics · doi:10.1118/1.2739811 · Cited by 263 · cited 1×
“On the CyberKnife® system, the hysteresis is addressed by using two quadratic functions without state augmentation: one for the inhale phase and one for the exhale phase (Seppenwoolde et al 2007).”
MethodThe Rotating Biplanar Linac–Magnetic Resonance Imaging System
Fallone, B. G. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.011 · Cited by 260 · cited 1×
“Additionally, two research groups operate prototype systems (Fallone 2014, Keall et al 2014a, Liney et al 2016).”
BackgroundReal-time tumour-tracking radiotherapy
Shirato, H., Shimizu, S., Shimizu, T., Nishioka, T., & Miyasaka, K. (1999) · The Lancet · doi:10.1016/s0140-6736(99)00700-x · Cited by 252 · cited 2×
“Instead the position of a FM is monitored in real-time and the treatment beam is gated (Shirato et al 1999).”
BackgroundMethodReport of AAPM TG 135: Quality assurance for robotic radiosurgery
Dieterich, S., Cavedon, C., Chuang, C. F., Cohen, A. B., Garrett, J. A., Lee, C. L., Lowenstein, J. R., d'souza, M. F., Taylor, D. D., Wu, X., et al. (2011) · Medical Physics · doi:10.1118/1.3579139 · Cited by 251
Aubry, J.-F., Beaulieu, L., Girouard, L.-M., Aubin, S., Tremblay, D., Laverdière, J., & Vigneault, E. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.02.045 · Cited by 163
Stereotactic Body Radiotherapy: An Emerging Treatment Approach for Localized Prostate Cancer
Friedland, J. L., Freeman, D. E., Masterson-McGary, M. E., & Spellberg, D. M. (2009) · Technology in Cancer Research & Treatment · doi:10.1177/153303460900800509 · Cited by 154
The Role of Optical Surface Imaging Systems in Radiation Therapy
Hoisak, J. D. P., & Pawlicki, T. A. (2018) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2018.02.003 · Cited by 152
Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy
Stemkens, B., Tijssen, R. H. N., de Senneville, B. D., Lagendijk, J. J. W., & van den Berg, C. A. T. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/14/5335 · Cited by 151
Image-guided radiosurgery for the spine and pancreas
Murphy, M. J., Adler, J. R., Bodduluri, M., Dooley, J., Forster, K., Hai, J., Le, Q., Luxton, G., Martin, D., & Poen, J. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<278::aid-igs6>3.0.co;2-k · Cited by 144
Hazelaar, C., van Eijnatten, M. A. J. M., Dahele, M. R., Wolff, J., Forouzanfar, T., Slotman, B. J., & Verbakel, W. F. A. R. (2017) · Medical Physics · doi:10.1002/mp.12644 · Cited by 144 · cited 4×
“This is the idea behind Sequential Stereo (Varian Medical System), which was recently used for online real-time 3D spine localization during VMAT SBRT delivery (Hazelaar et al 2018c).”
BackgroundMethodInfluentialPaganelli, C., Whelan, B., Peroni, M., Summers, P. E., Fast, M. F., van de Lindt, T. N., McClelland, J. R., Eiben, B., Keall, P., Lomax, A., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaebcf · Cited by 131 · cited 1×
“Recently, radiotherapy machines with integrated MR imaging have entered clinical practice (Paganelli et al 2018).”
BackgroundSelf-citationSu, T., Liang, P., Liang, J., Lu, H., Jiang, H.-Y., Cheng, T., Huang, Y., Tang, Y., & Deng, X. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.02.095 · Cited by 121 · cited 2×
“Remote probe support and robotic systems are also being developed to optimise probe placement during both patient set up and treatment delivery (Schlosser et al 2012, Sen et al 2017, Su et al 2017a).”
BackgroundPAX3: A Molecule with Oncogenic or Tumor Suppressor Function Is Involved in Cancer
Arasu, A., Murugan, S., Essa, M. M., Velusamy, T., & Guillemin, G. J. (2018) · BioMed Research International · doi:10.1155/2018/1095459 · Cited by 117
Feasibility of MRI guided proton therapy: magnetic field dose effects
Raaymakers, B. W., Raaijmakers, A. J. E., & Lagendijk, J. J. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/20/003 · Cited by 113
Čihorić, N., Tsikkinis, A., Minniti, G. C., Lagerwaard, F. J., Herrlinger, U., Mathier, E., Soldatović, I., Jeremic, B. M., Ghadjar, P., Eliçin, O., et al. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0740-5 · Cited by 102
A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation
Serban, M. F., Heath, E. C., Stroian, G., Collins, D. L., & Seuntjens, J. P. (2008) · Medical Physics · doi:10.1118/1.2836417 · Cited by 100 · cited 2×
“…of patient anatomy during end-to-end tests were also developed (Biederer et al 2006, Nioutsikou et al 2006, Kashani et al 2007, Remmert et al 2007, Serban et al 2008, Steidl et al 2012, Haas et al 2014, Cheung and Sawant 2015, Perrin et al 2017) with some representative examples summarized in…”
BackgroundBooth, J. T., Caillet, V., Hardcastle, N., O'Brien, R. T., Szymura, K., Crasta, C., Harris, B. D. W., Haddad, C. R., Eade, T., & Keall, P. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.08.025 · Cited by 98
Self-citationColvill, E., Booth, J., Nill, S., Fast, M. F., Bedford, J. L., Oelfke, U., Nakamura, M., Poulsen, P. R., Worm, E. S., Hansen, R., et al. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.03.006 · Cited by 97 · cited 2×
“US has been combined with MLC tracking in vitro (Fast et al 2016, Ipsen et al 2016) with a total system latency of ~1 s, therefore demonstrating adequate compensation for the slow motion typically observed in prostate cancer (Fast et al 2016, Colvill et al 2014). A predictive compensation method was demonstrated on si…”
BackgroundSelf-citationEvaluation of different fiducial markers for image-guided radiotherapy and particle therapy
Habermehl, D., Henkner, K., Ecker, S., Jäkel, O., Debus, J., & Combs, S. E. (2013) · Journal of Radiation Research · doi:10.1093/jrr/rrt071 · Cited by 94 · cited 3×
“In the PROMETHEUS trial carried out at the Heidelberg Ion Beam Therapy (HIT) Center, different markers were evaluated for suitability for the treatment of hepatocellular carcinoma using scanned ion beams (Habermehl et al 2013).”
BackgroundMethodInfluentialMalinowski, K. T., McAvoy, T. J., George, R., Dietrich, S., & D'Souza, W. D. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.02.048 · Cited by 90
Intra-fraction motion of the prostate is a random walk
Ballhausen, H., Li, M., Hegemann, N.-S., Ganswindt, U., & Belka, C. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/549 · Cited by 88 · cited 1×
“Characterisations of prostate motion during treatment describe a gradual drift from the isocentre with substantial inter-patients variations showing maximum recorded shifts >10 mm and a mean SI drift of 0.075 mm min−1 (Ballhausen et al 2015, Li et al 2017).”
BackgroundInfluentialFluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking
Tang, X., Sharp, G. C., & Jiang, S. B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/14/005 · Cited by 85
Zagar, T. M., Kaidar‐Person, O., Tang, X., Jones, E. E., Matney, J. E., Das, S. K., Green, R. L., Sheikh, A., Khandani, A. H., McCartney, W. H., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.12.017 · Cited by 82
Failure mode and effect analysis‐based quality assurance for dynamic MLC tracking systems
Sawant, A. R., Dieterich, S., Svatos, M. M., & Keall, P. (2010) · Medical Physics · doi:10.1118/1.3517837 · Cited by 80 · cited 1×
“In order to set-up a program that is both efficient and effective, Sawant et al (2010) used the failure mode and effect analysis (FMEA) framework to determine the frequency of QA tests for Calypso-guided MLC tracking.”
MethodSelf-citationBainbridge, H., Menten, M. J., Fast, M. F., Nill, S., Oelfke, U., & McDonald, F. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.09.009 · Cited by 80
Self-citationIntegrating a low-field open MR scanner with a static proton research beam line: proof of concept
Schellhammer, S. M., Hoffmann, A. L., Gantz, S., Smeets, J., van der Kraaij, E., Quets, S., Pieck, S., Karsch, L., & Pawelke, J. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaece8 · Cited by 75
Huang, C., Tehrani, J. N., Ng, J. A., Booth, J. T., & Keall, P. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.09.040 · Cited by 72 · cited 2×
“…centimetres has been observed in liver (Case et al 2009, Park et al 2012, Worm et al 2013, Xu et al 2014, Bertholet et al 2016), lung (Seppenwoolde et al 2002, Kyriakou and McKenzie 2012, Huang et al 2015, Schmidt et al 2016) and pancreas (Ahn et al 2004, Jones et al 2015, Campbell et al 2017a).”
BackgroundResultSelf-citationOrgan motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
Shirato, H., Shimizu, S., Kitamura, K., & Onimaru, R. (2007) · International Journal of Clinical Oncology · doi:10.1007/s10147-006-0633-y · Cited by 70 · cited 4×
“Shirato et al (2007) reported on the Hokkaido group experience in marker implantation in multiple sites with multiple techniques and reported successful implantation in 90 of 100 lesions without any serious complication.”
BackgroundInfluentialLuca, V. D., Banerjee, J., Hallack, A., Kondo, S., Makhinya, M., Nouri, D., Royer, L., Cifor, A., Dardenne, G., Göksel, O., et al. (2018) · Medical Physics · doi:10.1002/mp.13152 · Cited by 69
Self-citationQuantifying Rigid and Nonrigid Motion of Liver Tumors During Stereotactic Body Radiation Therapy
Xu, Q., Hanna, G. K., Grimm, J., Kubicek, G. J., Pahlajani, N., Asbell, S. O., Fan, J., Chen, Y., & LaCouture, T. A. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.007 · Cited by 64 · cited 1×
“…and quickly extract the position or outline of a volume-of-interest from 2D cine MR images (Cerviño et al 2011, Shi et al 2014, Mazur et al 2015, Paganelli et al 2015, Yun et al 2015, Feng et al 2016, Bourque et al 2016, Yip et al 2018) with an accuracy approaching inter-observer variability.”
BackgroundThomas, D., Lamb, J., White, B., Jani, S. S., Gaudio, S., Lee, P. P., Ruan, D., McNitt‐Gray, M. F., & Low, D. A. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.01.016 · Cited by 62
A limited‐angle intrafraction verification (LIVE) system for radiation therapy
Ren, L., Zhang, Y., & Yin, F.-F. (2014) · Medical Physics · doi:10.1118/1.4861820 · Cited by 60 · cited 1×
“More recently a number of groups have developed sophisticated methods to determine the lung tumour position from these images (Lewis et al 2010, Ren et al 2014, Zhang et al 2014a, Shieh et al 2017, Hazelaar et al 2018a).”
MethodKinoshita, R., Shimizu, S., Taguchi, H., Katoh, N., Fujino, M., Onimaru, R., Aoyama, H., Katoh, F., Omatsu, T., Ishikawa, M., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.10.003 · Cited by 60 · cited 3×
“Important considerations for QA procedures are the latencies and geometric tolerances as well as the complexicity and frequency of the tests. Ng et al (2014) chose a 1 mm geometric tolerance for the KIM QA program as it is well below typical margins and in line with other geometric errors such as isocenters or couch c…”
BackgroundMethodInfluentialKubiak, T. (2016) · British Journal of Radiology · doi:10.1259/bjr.20150275 · Cited by 60 · cited 2×
“Implanted FMs are associated with specific particle therapy-related challenges requiring particular precaution (Kubiak 2016).”
BackgroundMethodMcClelland, J. R., Marc Modat, A., Arridge, S., Grimes, H., D’Souza, D., Thomas, D. H., Connell, D. O., Low, D. A., Kaza, E., Collins, D. J., et al. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6070 · Cited by 53 · cited 1×
“Alternatively, methods have been proposed that fit the motion models directly to unsorted partial or raw imaging data, e.g. cine CT volumes, CT/MR slices (McClelland et al 2017), or CBCT projections (Martin et al 2014).”
Self-citationDelivering Functional Imaging on the MRI-Linac: Current Challenges and Potential Solutions
Datta, A., Aznar, M. C., Dubec, M. J., Parker, G. J. M., & O’Connor, J. P. B. (2018) · Clinical Oncology · doi:10.1016/j.clon.2018.08.005 · Cited by 53 · cited 8×
“Real-time monoscopic target localization in general uses the projected target position in a sequence of training images from different angles to establish a model that allows Phys. Med. Biol. 64 (2019) 15TR01 (33pp)”
BackgroundMethodInfluentialDosimetric feasibility of intensity modulated proton therapy in a transverse magnetic field of 1.5 T
Hartman, J., Kontaxis, C., Bol, G. H., Frank, S. J., Lagendijk, J. J. W., van Vulpen, M., & Raaymakers, B. W. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/15/5955 · Cited by 53 · cited 1×
“…about online MR-guided proton therapy have been published in the recent years (Raaymakers et al 2008, Wolf and Bortfeld 2012, Moteabbed et al 2014, Hartman et al 2015, Oborn et al 2015, Fuchs et al 2017, Schellhammer et al 2018), envisioning new ways to enable motion monitoring and mitigation.”
BackgroundDMLC tracking and gating can improve dose coverage for prostate VMAT
Colvill, E., Poulsen, P. R., Booth, J. T., O'Brien, R. T., Ng, J. A., & Keall, P. (2014) · Medical Physics · doi:10.1118/1.4892605 · Cited by 53 · cited 1×
“US has been combined with MLC tracking in vitro (Fast et al 2016, Ipsen et al 2016) with a total system latency of ~1 s, therefore demonstrating adequate compensation for the slow motion typically observed in prostate cancer (Fast et al 2016, Colvill et al 2014).”
MethodSelf-citationYuen, J., Rodrigues, G., Trenka, K., Coad, T., Yartsev, S., D'Souza, D. P., Lock, M. I., & Bauman, G. S. (2008) · Radiation Oncology · doi:10.1186/1748-717x-3-1 · Cited by 52
Neural‐network based autocontouring algorithm for intrafractional lung‐tumor tracking using Linac‐MR
Yun, J., Yip, E., Gabos, Z., Wachowicz, K., Rathee, S., & Fallone, B. G. (2015) · Medical Physics · doi:10.1118/1.4916657 · Cited by 52 · cited 1×
“…and quickly extract the position or outline of a volume-of-interest from 2D cine MR images (Cerviño et al 2011, Shi et al 2014, Mazur et al 2015, Paganelli et al 2015, Yun et al 2015, Feng et al 2016, Bourque et al 2016, Yip et al 2018) with an accuracy approaching inter-observer variability.”
BackgroundTetar, S., Bruynzeel, A. M. E., Bakker, R., Jeulink, M., Slotman, B. J., Oei, S. S., Haasbeek, C. J. A., Jong, K. D., Senan, S., & Lagerwaard, F. J. (2018) · Cureus · doi:10.7759/cureus.2236 · Cited by 48 · cited 2×
“However, few clinics have begun to deploy on-board MR imaging to guide intrafractional treatment beam gating on the ViewRay MRIdian (Green et al 2018, Henke et al 2018, Tetar et al 2018).”
MethodReal‐time 4D dose reconstruction for tracked dynamic MLC deliveries for lung SBRT
Kamerling, C. P., Fast, M. F., Ziegenhein, P., Menten, M. J., Nill, S., & Oelfke, U. (2016) · Medical Physics · doi:10.1118/1.4965045 · Cited by 47 · cited 3×
“However, ITV and mid-ventilation approaches may result in large irradiated volumes leading to high dose delivery to the organs at risk (OAR) (Wolthaus et al 2008, Ehrbar et al 2016, Kamerling et al 2016a) while target coverage is not guaranteed, especially in the presence of tumour drift.”
BackgroundSelf-citationLocating and targeting moving tumors with radiation beams
Dieterich, S., Cleary, K., D'Souza, W. D., Murphy, M. J., Wong, K. H., & Keall, P. (2008) · Medical Physics · doi:10.1118/1.3020593 · Cited by 46 · cited 1×
“…or passive, will not be discussed in depth in this review; instead we refer the reader to the AAPM Task group 76 report (Keall et al 2006), the paper by Dieterich et al (2008) and, for proton therapy, to the consensus guidelines of the PTCOG thoracic and lymphoma subcommittee (Chang et al 2017).”
MethodSelf-citationNguyen, D. T., O'Brien, R. T., Kim, J., Huang, C., Wilton, L., Greer, P. B., Legge, K., Booth, J., Poulsen, P. R., Martin, J. M., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.02.013 · Cited by 45 · cited 2×
“Recently, the KIM system has been extended for six degrees of freedom (DoF) motion monitoring in prostate patients (Nguyen et al 2017b).”
BackgroundMethodSelf-citationTrnková, P., Knäusl, B., Actis, O., Bert, C., Biegun, A. K., Böhlen, T. T., Furtado, H., McClelland, J. R., Mori, S., Rinaldi, I., et al. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.10.002 · Cited by 43 · cited 1×
“The translation of photon therapy motion monitoring concepts to particle therapy facilities was mentioned in numerous publications (Riboldi et al 2012, Shirato et al 2012, Seco and Spadea 2015, Knopf et al 2016, Kubiak 2016, Trnková et al 2018).”
MethodSelf-citationMazur, T. R., Fischer-Valuck, B. W., Wang, Y., et al. (2015) · Medical Physics · doi:10.1118/1.4938096 · Cited by 41
A comparative study of automatic image segmentation algorithms for target tracking in MR‐IGRT
Feng, Y., Kawrakow, I., Olsen, J., Parikh, P. J., Noel, C. E., Wooten, O., Du, D., Mutic, S., & Hu, Y. (2016) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v17i2.5820 · Cited by 39 · cited 1×
“…and quickly extract the position or outline of a volume-of-interest from 2D cine MR images (Cerviño et al 2011, Shi et al 2014, Mazur et al 2015, Paganelli et al 2015, Yun et al 2015, Feng et al 2016, Bourque et al 2016, Yip et al 2018) with an accuracy approaching inter-observer variability.”
Rydhög, J. S., de Blanck, S. R., Josipović, M., Jølck, R. I., Larsen, K. R., Clementsen, P. F., Andersen, T. L., Poulsen, P. R., Persson, G. F., & af Rosenschöld, P. M. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.02.003 · Cited by 39
Self-citationRadiolucent 4D Ultrasound Imaging: System Design and Application to Radiotherapy Guidance
Schlosser, J., & Hristov, D. H. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2559499 · Cited by 29 · cited 1×
“Another mitigation strategy has been pursued whereby a probe was manufactured using radiolucent materials to reduce interference with the treatment beam (Schlosser and Hristov 2016).”
BackgroundMenten, M. J., Gückenberger, M., Herrmann, C., et al. (2012) · Medical Physics · doi:10.1118/1.4761868 · Cited by 28
Self-citationIon beam tracking using ultrasound motion detection
Prall, M., Kaderka, R., Saito, N., Graeff, C., Bert, C., Durante, M., Parodi, K., Schwaab, J., Sarti, C., & Jenne, J. (2014) · Medical Physics · doi:10.1118/1.4868459 · Cited by 28
Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters
Campbell, W. G., Miften, M. M., & Jones, B. L. (2016) · Medical Physics · doi:10.1002/mp.12073 · Cited by 25
A kernel-based method for markerless tumor tracking in kV fluoroscopic images
Zhang, X., Homma, N., Ichiji, K., Abe, M., Sugita, N., Takai, Y., Narita, Y., & Yoshizawa, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/17/4897 · Cited by 25 · cited 2×
“More recently a number of groups have developed sophisticated methods to determine the lung tumour position from these images (Lewis et al 2010, Ren et al 2014, Zhang et al 2014a, Shieh et al 2017, Hazelaar et al 2018a).”
BackgroundMethodFDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism
Roach, M. C., Turkington, T. G., Higgins, K. A., Hawk, T. C., Hoang, J. K., & Brizel, D. M. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.055 · Cited by 25
Fargier-Voiron, M., Presles, B., Pommier, P., Muñoz, A., Rit, S., Sarrut, D., & Biston, M. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.01.481 · Cited by 24 · cited 1×
“Fargier-Voiron et al (2016) and Li et al (2017) have identified a need to control for anatomical deformation and changes to image quality associated with variations in probe pressure.”
BackgroundRespiratory Motion Estimation from Cone-Beam Projections Using a Prior Model
Vandemeulebroucke, J., Kybic, J., Clarysse, P., & Sarrut, D. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-04271-3_45 · Cited by 24 · cited 1×
“…have also been proposed that indirectly model the relationship between the internal motion and the surrogate data, enabling the use of real-time 2D imaging as surrogate data, such as kV-MV projection images (Vandemeulebroucke et al 2009) or 2D cine MR images (Stemkens et al 2016) (see section 2.5).”
MethodInfluentialBuilding motion models of lung tumours from cone-beam CT for radiotherapy applications
Martin, J., McClelland, J. R., Yip, C., Thomas, C., Hartill, C., Ahmad, S., O’Brien, R., Meir, I., Landau, D., & Hawkes, D. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/6/1809 · Cited by 24
Self-citationReal‐time automatic fiducial marker tracking in low contrast cine‐MV images
Lin, W., Lin, S., Yang, S., Liou, S., Nath, R., & Liu, W. (2012) · Medical Physics · doi:10.1118/1.4771931 · Cited by 22
Wölfelschneider, J., Seregni, M., Fassi, A., et al. (2017) · Medical Physics · doi:10.1002/mp.12243 · Cited by 20
Omari, E. A., Erickson, B. A., Ehlers, C., Quiroz, F. A., Noid, G., Cooper, D. T., Lachaine, M. E., & Li, X. A. (2016) · Medical Physics · doi:10.1118/1.4960004 · Cited by 18
Chen, T., Qin, S., Xu, X., Jabbour, S. K., Haffty, B. G., & Yue, N. J. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.08.007 · Cited by 17 · cited 1×
“Cardiac activity can also have a substantial effect on the position of lung tumours, mediastinal lymph nodes (Seppenwoolde et al 2002, Chen et al 2014, Schmidt et al 2016, Scherman Rydhög et al 2017) or liver tumours (Kitamura et al 2003, Bertholet et al 2016).”
BackgroundVanhanen, A., Syrén, H., & Kapanen, M. K. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.11.007 · Cited by 14 · cited 1×
“…procedures were feasible and safe, but the studies also reported interfractional transmitter position instabilities and recommended to combine real-time prostate motion monitoring by RayPilot with an independent IGRT system for daily prostate localization (Braide et al 2018, Vanhanen et al 2018).”
BackgroundUsing dynamic programming to improve fiducial marker localization
Wan, H., Ge, J., & Parikh, P. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/8/1935 · Cited by 8 · cited 1×
“Template-free methods were also proposed using machine-learning with manually labelled data from the first treatment fraction as training dataset (Lin et al 2013) or using a dynamic programming (DP)-based method (Wan et al 2014, 2016).”
MethodAutomated patient setup and gating using cone beam computed tomography projections
Wan, H., Bertholet, J., Ge, J., Poulsen, P. R., & Parikh, P. J. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/6/2552 · Cited by 7 · cited 1×
“Template-free methods were also proposed using machine-learning with manually labelled data from the first treatment fraction as training dataset (Lin et al 2013) or using a dynamic programming (DP)-based method (Wan et al 2014, 2016).”
MethodSelf-citationA new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy
Chi, Y., Rezaeian, N. H., Shen, C., Zhou, Y., Lu, W., Yang, M., Hannan, R., & Jia, X. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6e37 · Cited by 4 · cited 1×
“Erratic motion of the prostate, including rotation, was also reported in several studies (Aubry et al 2004, Ghilezan et al 2005, Kupelian et al 2007, Langen et al 2008, Poulsen et al 2008b, Ng et al 2012, Huang et al 2015, Hunt et al 2016, Tynan et al 2016, Chi et al 2017).”
Result
Metadata
- Authors
- Bertholet, J., Knopf, A., Eiben, B., McClelland, J., Grimwood, A., Harris, E., Menten, M., Poulsen, P., Nguyen, D. T., Keall, P., & Oelfke, U.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-08-01
- Volume
- 64
- Issue
- 15
- Pages
- 15TR01
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2952945079
- Cited by
- 229
- References
- 95
- FWCI
- 20.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.