Impact of image preprocessing on the scanner dependence of multi-parametric MRI radiomic features and covariate shift in multi-institutional glioblastoma datasets
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Recent advances in radiomics have enhanced the value of medical imaging in various aspects of clinical practice, but a crucial component that remains to be investigated further is the robustness of quantitative features to imaging variations and across multiple institutions. In the case of MRI, signal intensity values vary according to the acquisition parameters used, yet no consensus exists on which preprocessing techniques are favorable in reducing scanner-dependent variability of image-based features. Hence, the purpose of this study was to assess the impact of common image preprocessing methods on the scanner dependence of MRI radiomic features in multi-institutional glioblastoma multiforme (GBM) datasets. Two independent GBM cohorts were analyzed: 50 cases from the TCGA-GBM dataset and 111 cases acquired in our institution, and each case consisted of 3 MRI sequences viz. FLAIR, T1-weighted, and T1-weighted post-contrast. Five image preprocessing techniques were examined: 8-bit global rescaling, 8-bit local rescaling, bias field correction, histogram standardization, and isotropic resampling. A total of 420 features divided into eight categories representing texture, shape, edge, and intensity histogram were extracted. Two distinct imaging parameters were considered: scanner manufacturer and scanner magnetic field strength. Wilcoxon tests identified features robust to the considered acquisition parameters under the selected image preprocessing techniques. A machine learning-based strategy was implemented to measure the covariate shift between the analyzed datasets using features computed using the aforementioned preprocessing methods. Finally, radiomic scores (rad-scores) were constructed by identifying features relevant to patients’ overall survival after eliminating those impacted by scanner variability. These were then evaluated for their prognostic significance through Kaplan–Meier and Cox hazards regression analyses. Our results demonstrate that overall, histogram standardization contributes the most in reducing radiomic feature variability as it is the technique to reduce the covariate shift for three feature categories and successfully discriminate patients into groups of different survival risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Comparison of the predicted and observed secondary structure of T4 phage lysozyme
Matthews, B. W. (1975) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(75)90109-9 · Cited by 5,399
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 2×
“Edge features were calculated through the use of four different types edge filters: Sobel, Laplacian of Gaussian (LoG), Gabor, and Wavelet. The filters were first convolved with those slices of the MRI containing the regions of interest (tumor or lateral ventricles) and four first order statistics (mean, standard devi…”
InfluentialA nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599 · cited 2×
“The discovery cohort consisted of MR images downloaded from the cancer genome atlas glioblastoma multiforme (TCGA-GBM) collection of the Cancer Imaging Archive (TCIA) (Clark et al 2013).”
MethodOptimal classifier for imbalanced data using Matthews Correlation Coefficient metric
Boughorbel, S., Jarray, F., & El-Anbari, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177678 · Cited by 1,222
Glioblastoma Multiforme: Exploratory Radiogenomic Analysis by Using Quantitative Image Features
Gevaert, O., Mitchell, L. A., Achrol, A. S., Xu, J., Echegaray, S., Steinberg, G. K., Cheshier, S. H., Napel, S., Zaharchuk, G., & Plevritis, S. K. (2014) · Radiology · doi:10.1148/radiol.14131731 · Cited by 319 · cited 1×
“Our hypothesis is based on previous studies (Gevaert et al 2014, Zhou et al 2014) that explain differences in tumor appearance arise from variations in underlying tumor biology, including genomics.”
Method
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Carré, A., Klausner, G., Edjlali, M., Lerousseau, M., Briend-Diop, J., Sun, R., Ammari, S., Reuzé, S., Alvarez Andres, E., Estienne, T., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69298-z · Cited by 278
Moradmand, H., Aghamiri, S. M. R., & Ghaderi, R. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12795 · Cited by 173
The effect of preprocessing filters on predictive performance in radiomics
Demircioğlu, A. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00294-w · Cited by 75
Minimising multi-centre radiomics variability through image normalisation: a pilot study
Campello, V. M., Martín-Isla, C., Izquierdo, C., Guala, A., Palomares, J. F. R., Viladés, D., Descalzo, M. L., Karakas, M., Çavuş, E., Raisi-Estabragh, Z., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-16375-0 · Cited by 24
Metadata
- Authors
- Um, H., Tixier, F., Bermudez, D., Deasy, J. O., Young, R. J., & Veeraraghavan, H.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-08-01
- Volume
- 64
- Issue
- 16
- Pages
- 165011
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2954499387
- Cited by
- 120
- References
- 11
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of image preprocessing on the scanner dependence of multi-parametric MRI radiomic features and covariate shift in multi-institutional glioblastoma datasets. https://app.cochat.ai/papers/10.1088/1361-6560/ab2f44
- The paper
- Um, H., Tixier, F., Bermudez, D., Deasy, J. O., Young, R. J., & Veeraraghavan, H. (2019). Impact of image preprocessing on the scanner dependence of multi-parametric MRI radiomic features and covariate shift in multi-institutional glioblastoma datasets. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab2f44
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.