Reducing crosstalk in optically-pumped magnetometer arrays
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Optically pumped magnetometers (OPMs) operating in the spin-exchange relaxation-free regime are emerging as alternative sensors to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). As the number of OPMs in a single imaging system increases to rival SQUID MEG systems, cross-talk between nearby sensors limits the measurement accuracy. We experimentally demonstrate a coil geometry, which generates an order of magnitude less cross-talk (less than 0.5%) than a Helmholtz coil (8%). The new coil design is simple and compact, requiring two coaxial coil pairs that add 1 mm to the 6 mm radius and is driven by a single current driver. The new design maintains a magnetic field homogeneity over the volume of the magnetometer of more than 94%, which is sufficient for the zero-field OPM to operate in a 200 nT ambient field environment. Our result increases the feasibility of high-spatial resolution OPM-based bio-magnetic imaging technology due to the reduction of cross-talk at high sensor density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 1×
“Unless two magnetometers are very close and are oriented at an angle that is large, this effect is small (a maximum of 5°) (Boto et al 2018).”
BackgroundHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In order to reach high field sensitivities, the OPMs are operated in the regime where decoherence from spin-exchange collisions is suppressed: at very low ambient magnetic fields and high 87Rb densities (Happer and Tang 1973, Allred et al 2002).”
BackgroundMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 1×
“Recent studies simulating whole-head MEG systems with on-scalp sensors promise greatly increased spatial resolution compared to the current SQUID-based MEG systems (Luessi et al 2014, Boto et al 2016, Iivanainen et al 2017).”
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194 · cited 1×
“Recent studies simulating whole-head MEG systems with on-scalp sensors promise greatly increased spatial resolution compared to the current SQUID-based MEG systems (Luessi et al 2014, Boto et al 2016, Iivanainen et al 2017).”
A microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179 · cited 1×
“A detailed description of the sensor geometry can be found in Sheng et al (2017).”
MethodSelf-citation
Cited by
Borna, A., Iivanainen, J., Carter, T. R., McKay, J., Taulu, S., Stephen, J., & Schwindt, P. D. D. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118818 · Cited by 120
Nugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41
A modular optically pumped magnetometer system
Coussens, T., Gialopsou, A., Abel, C., Bason, M. G., James, T. M., Evans, W., Woodley, M. T. M., Nightingale, D., Nicolau, D., Page, L., et al. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4e60 · Cited by 11
“Commercially available OPMs currently focus on single-sensor designs; when multiple units are operated in close proximity, issues arise from radio frequency (RF) cross-talk [19], cross-axis projection errors [20], as well as from high surface temperatures of the sensors.”
Background
Metadata
- Authors
- Nardelli, N. V., Krzyzewski, S. P., & Knappe, S. A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-11-01
- Volume
- 64
- Issue
- 21
- Pages
- 21NT03
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2979938894
- Cited by
- 80
- References
- 5
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing crosstalk in optically-pumped magnetometer arrays. https://app.cochat.ai/papers/10.1088/1361-6560/ab4c06
- The paper
- Nardelli, N. V., Krzyzewski, S. P., & Knappe, S. A. (2019). Reducing crosstalk in optically-pumped magnetometer arrays. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab4c06
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.