CoChat

A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration

Open access
Jiang, Zhuoran, Yin, Fang-Fang, Ge, Yun, Ren, Lei · 2020 · Physics in Medicine & Biology
Cited by 94

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It is trained based on image similarity and deformation vector field (DVF) smoothness, requiring no supervision of ground-truth DVF. The three models are first trained sequentially and separately for their own registration tasks, and then are trained jointly for an end-to-end optimization under the multi-scale framework. In this study, MJ-CNN was trained using public SPARE 4D-CT data. The trained MJ-CNN was then evaluated on public DIR-LAB 4D-CT dataset as well as clinical CT-to-CBCT and CBCT-to-CBCT registration. For 4D-CT inter-phase registration, MJ-CNN achieved comparable accuracy to conventional iteration optimization-based methods, and showed the smallest registration errors compared to recently published deep learning-based DIR methods, demonstrating the efficacy of the proposed multi-scale joint training scheme. Besides, MJ-CNN trained using one dataset (SPARE) could generalize to a different dataset (DIR-LAB) acquired by different scanners and imaging protocols. Furthermore, MJ-CNN trained on 4D-CTs also performed well on CT-to-CBCT and CBCT-to-CBCT registration without any re-training or fine-tuning, demonstrating MJ-CNN’s robustness against applications and imaging techniques. MJ-CNN took about 1.4 s for DVF estimation and required no manual-tuning of parameters during the evaluation. MJ-CNN is able to perform accurate DIR for pulmonary CT with nearly real-time speed, making it very applicable for clinical tasks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/ab5da0

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 94

Metadata

Authors
Jiang, Z., Yin, F.-F., Ge, Y., & Ren, L.
Venue
Physics in Medicine & Biology
Published
2020-01-01
Volume
65
Issue
1
Pages
015011
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2990081072
Cited by
94
References
4
FWCI
4.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration. https://app.cochat.ai/papers/10.1088/1361-6560/ab5da0
The paper
Jiang, Z., Yin, F.-F., Ge, Y., & Ren, L. (2020). A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab5da0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.