Non-invasive blood glucose detection system based on conservation of energy method
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The most common method used for minimizing the occurrence of diabetes complications is frequent glucose testing to adjust the insulin dose. However, using blood glucose (BG) meters presents a risk of infection. It is of great importance to develop non-invasive BG detection techniques. To realize high-accuracy, low-cost and continuous glucose monitoring, we have developed a non-invasive BG detection system using a mixed signal processor 430 (MSP430) microcontroller. This method is based on the combination of the conservation-of-energy method with a sensor integration module, which collects physiological parameters, such as the blood oxygen saturation (SPO 2 ), blood flow velocity and heart rate. New methods to detect the basal metabolic rate (BMR) and BV are proposed, which combine the human body heat balance and characteristic signals of photoplethysmography as well dual elastic chambers theory. Four hundred clinical trials on real-time non-invasive BG monitoring under suitable experiment conditions were performed on different individuals, including diabetic patients, senior citizens and healthy adults. A multisensory information fusion model was applied to process these samples. The algorithm (we defined it as DCBPN algorithm) applied in the model combines a decision tree and back propagation neural network, which classifies the physiological and environmental parameters into three categories, and then establishes a corresponding prediction model for the three categories. The DCBPN algorithm provides an accuracy of 88.53% in predicting the BG of new samples. Thus, this system demonstrates a great potential to reliably detect BG values in a non-invasive setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Monte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Noninvasive glucose monitoring using saliva nano-biosensor
Zhang, W., Du, Y., & Wang, M. L. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.02.002 · Cited by 232
Cited by
Artificial intelligence for diabetes management and decision support: Literature review
Contreras, I., & Vehi, J. (2018) · Journal of Medical Internet Research · doi:10.2196/10775 · Cited by 560
“2017 [78] DT, ANN SMBG 2 h 1 day 500 T1D, T2D 0 min”
Artificial intelligence in diabetes management: Advancements, opportunities, and challenges
Guan, Z., Li, H., Liu, R., Cai, C., Liu, Y., Li, J., Wang, X., Huang, S., Wu, L., Liu, D., et al. (2023) · Cell Reports Medicine · doi:10.1016/j.xcrm.2023.101213 · Cited by 412
“78 For detecting hypoglycemia, Kodama et al. summarized that the pooled estimates of sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were 0.79, 0.80, 8.05, and 0.18, respectively.”
BackgroundInfluentialMachine Learning and Smart Devices for Diabetes Management: Systematic Review
Makroum, M. A., Adda, M., Bouzouane, A., & Ibrahim, H. (2022) · Sensors · doi:10.3390/s22051843 · Cited by 145
“[83] Development of a non-invasive blood glucose detection device with high accuracy, low cost, and continuous glucose monitoring.”
BackgroundIn-Vivo Estimation of Glucose Level Using PPG Signal
Gupta, S. S., Hossain, S., Haque, C. A., & Kim, K.-D. (2020) · 2020 International Conference on Information and Communication Technology Convergence (ICTC) · doi:10.1109/ictc49870.2020.9289629 · Cited by 12
“Based on human body heat balance and PPG signals authors of [14], proposed a non-invasive technique to measure blood glucose with Sp02, blood flow velocity and heart rate.”
Method
Metadata
- Authors
- Zhang, Y., Zhu, J.-M., Liang, Y.-B., Chen, H.-B., Yin, S.-M., & Chen, Z.-C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2017-01-20
- Volume
- 38
- Issue
- 2
- Pages
- 325-342
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2571597664
- Cited by
- 32
- References
- 5
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.