Classification methods to detect sleep apnea in adults based on respiratory and oximetry signals: a systematic review
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Sleep apnea (SA), a common sleep disorder, can significantly decrease the quality of life, and is closely associated with major health risks such as cardiovascular disease, sudden death, depression, and hypertension. The normal diagnostic process of SA using polysomnography is costly and time consuming. In addition, the accuracy of different classification methods to detect SA varies with the use of different physiological signals. If an effective, reliable, and accurate classification method is developed, then the diagnosis of SA and its associated treatment will be time-efficient and economical. This study aims to systematically review the literature and present an overview of classification methods to detect SA using respiratory and oximetry signals and address the automated detection approach. APPROACH: Sixty-two included studies revealed the application of single and multiple signals (respiratory and oximetry) for the diagnosis of SA. MAIN RESULTS: Both airflow and oxygen saturation signals alone were effective in detecting SA in the case of binary decision-making, whereas multiple signals were good for multi-class detection. In addition, some machine learning methods were superior to the other classification methods for SA detection using respiratory and oximetry signals. SIGNIFICANCE: To deal with the respiratory and oximetry signals, a good choice of classification method as well as the consideration of associated factors would result in high accuracy in the detection of SA. An accurate classification method should provide a high detection rate with an automated (independent of human action) analysis of respiratory and oximetry signals. Future high-quality automated studies using large samples of data from multiple patient groups or record batches are recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, P. E., Young, T., Barnet, J. H., Palta, M., Hagen, E. W., & Hla, K. M. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws342 · Cited by 4,618
Phoneme recognition using time-delay neural networks
Waibel, A., Hanazawa, T., Hinton, G., Shikano, K., & Lang, K. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.21701 · Cited by 2,643 · cited 1×
“A TDNN is able to recognize features independent of time-shift (Waibel et al 1989).”
BackgroundKushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
The Influence of Increasing Ventilatory Effort on Arousal from Sleep
Gleeson, K., Zwillich, C. W., & White, D. P. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.2.295 · Cited by 411
The Visual Scoring of Sleep and Arousal in Infants and Children
Grigg-Damberger, M., Gozal, D., Marcus, C. L., Quan, S. F., Rosen, C. L., Chervin, R. D., Wise, M., Picchietti, D. L., Sheldon, S. H., & Iber, C. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26819 · Cited by 361 · cited 1×
“Sleep technologists monitor and manually review the overnight study for designating sleep stages and apneic type and length according to the American Academy of Sleep Medicine (AASM) guidelines (Grigg-Damberger et al 2007).”
MethodObstructive Sleep Apnea Syndrome
BETTEGA, G., PÉPIN, J.-L., VEALE, D., DESCHAUX, C., RAPHAËL, B., & LÉVY, P. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9904058 · Cited by 215
Berger, M., Oksenberg, A., Silverberg, D., Arons, E., Radwan, H., & Iaina, A. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000510 · Cited by 75
Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea
del Campo, F., Hornero, R., Zamarrón, C., Abasolo, D. E., & Álvarez, D. (2006) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2005.10.005 · Cited by 56 · cited 2×
“…articles used nonlinear analysis of nocturnal oximetry signal to distinguish OSA positive and OSA negative patients (Álvarez et al 2006a, 2006b, del Campo et al 2006, Álvarez et al 2007a, 2007b, Hornero et al 2007, Marcos et al 2011), whereas Marcos et al (2007) and Álvarez et al (2010b) added…”
BackgroundMethod
Cited by
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“Oximetry alone demonstrates significant variability in diagnostic accuracy, with reported sensitivity ranging from 31–98% and specificity 41–100% (38).”
BackgroundFeasibility of Single Channel Oximetry for Mass Screening of Obstructive Sleep Apnea
Behar, J. A., Palmius, N., Li, Q., Garbuio, S., Rizzatti, F. P. G., Bittencourt, L., Tufik, S., & Clifford, G. D. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.05.015 · Cited by 37
Behar, J. A., Palmius, N., Zacharie, S., Chocron, A., Penzel, T., Bittencourt, L., & Tufik, S. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab8856 · Cited by 20
Getting More from the Sleep Recording
McNicholas, W. T. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.001 · Cited by 3
Metadata
- Authors
- Uddin, M. B., Chow, C. M., & Su, S. W.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2018-03-26
- Volume
- 39
- Issue
- 3
- Pages
- 03TR01
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2789916407
- Cited by
- 76
- References
- 9
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.