Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

ECG signal classification for the detection of cardiac arrhythmias using a convolutional recurrent neural network

Open access
Xiong, Zhaohan, Nash, Martyn P, Cheng, Elizabeth, Fedorov, Vadim V, Stiles, Martin K, Zhao, Jichao · 2018 · Physiological Measurement

Abstract

OBJECTIVE: The electrocardiogram (ECG) provides an effective, non-invasive approach for clinical diagnosis in patients with cardiac diseases such as atrial fibrillation (AF). AF is the most common cardiac rhythm disturbance and affects ~2% of the general population in industrialized countries. Automatic AF detection in clinics remains a challenging task due to the high inter-patient variability of ECGs, and unsatisfactory existing approaches for AF diagnosis (e.g. atrial or ventricular activity-based analyses). APPROACH: We have developed RhythmNet, a 21-layer 1D convolutional recurrent neural network, trained using 8528 single-lead ECG recordings from the 2017 PhysioNet/Computing in Cardiology (CinC) Challenge, to classify ECGs of different rhythms including AF automatically. Our RhythmNet architecture contained 16 convolutions to extract features directly from raw ECG waveforms, followed by three recurrent layers to process ECGs of varying lengths and to detect arrhythmia events in long recordings. Large 15 × 1 convolutional filters were used to effectively learn the detailed variations of the signal within small time-frames such as the P-waves and QRS complexes. We employed residual connections throughout RhythmNet, along with batch-normalization and rectified linear activation units to improve convergence during training. MAIN RESULTS: accuracy of 82% for classifying sinus rhythm, AF, and other arrhythmias. RhythmNet was also ranked 5th in the 2017 CinC Challenge. SIGNIFICANCE: Potentially, our approach could aid AF diagnosis in clinics and be used for patient self-monitoring to improve the early detection and effective treatment of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/aad9ed

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Research works printed but not linked: 47

  1. Alcaraz, 2010, Optimal parameters study for sample entropy-based atrial fibrillation organization analysis, Comput. Methods Prog. Biomed., 99, 124, 10.1016/j.cmpb.2010.02.009 · DOI
  2. Alcaraz, 2006, Wavelet sample entropy: a new approach to predict termination of atrial fibrillation, Comput. Cardiol., 33, 597
  3. Babaeizadeh, 2009, Improvements in atrial fibrillation detection for real-time monitoring, J. Electrocardiol., 42, 522, 10.1016/j.jelectrocard.2009.06.006 · DOI · Paper page
  4. Baccouche, 2011, Sequential deep learning for human action recognition, 29, 10.1007/978-3-642-25446-8_4 · DOI · Paper page
  5. Bengio, 1993, The problem of learning long-term dependencies in recurrent networks, 1183, 10.1109/ICNN.1993.298725 · DOI · Paper page
  6. Carrara, 2015, Heart rate dynamics distinguish among atrial fibrillation, normal sinus rhythm and sinus rhythm with frequent ectopy, Physiol. Meas., 36, 1873, 10.1088/0967-3334/36/9/1873 · DOI
  7. Cervigón, 2010, Entropy measurements in paroxysmal and persistent atrial fibrillation, Physiol. Meas., 31, 1011, 10.1088/0967-3334/31/7/010 · doi:10.1088/0967-3334/31/7/010
  8. Cortes, 1995, Support vector machine, Mach. Learn., 20, 273, 10.1023/A:1022627411411 · DOI
  9. Datta, 2017, Identifying normal AF and other abnormal ECG rhythms using a cascaded binary classifier, Computing, 44, 1
  10. Demazumder, 2013, Dynamic analysis of cardiac rhythms for discriminating atrial fibrillation from lethal ventricular arrhythmias, Circulation, 6, 555
  11. Du, 2014, A novel method for real‐time atrial fibrillation detection in electrocardiograms using multiple parameters, Ann. Noninvasive Electrocardiol., 19, 217, 10.1111/anec.12111 · DOI
  12. García, 2016, Application of the relative wavelet energy to heart rate independent detection of atrial fibrillation, Comput. Methods Prog. Biomed., 131, 157, 10.1016/j.cmpb.2016.04.009 · DOI
  13. Haissaguerre, 1998, Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins, New Engl. J. Med., 339, 659, 10.1056/NEJM199809033391003 · DOI · Paper page
  14. Haïssaguerre, 2008, The substrate maintaining persistent atrial fibrillation, Circulation, 1, 2
  15. Hansen, 2015, Atrial fibrillation driven by micro-anatomic intramural re-entry revealed by simultaneous sub-epicardial and sub-endocardial optical mapping in explanted human hearts, Eur. Heart J., 36, 2390, 10.1093/eurheartj/ehv233 · DOI · Paper page
  16. Hershey, 2017, CNN architectures for large-scale audio classification, 131, 10.1109/ICASSP.2017.7952132 · DOI · Paper page
  17. Hong, 2017, ENCASE: an ensemble classifier for ECG classification using expert features and deep neural networks, 1, 10.22489/CinC.2017.178-245 · DOI · Paper page
  18. Huang, 2011, A novel method for detection of the transition between atrial fibrillation and sinus rhythm, IEEE Trans. Biomed. Eng., 58, 1113, 10.1109/TBME.2010.2096506 · DOI · Paper page
  19. Kim, 2014, Convolutional neural networks for sentence classification, 10.3115/v1/D14-1181 · DOI · Paper page
  20. Ladavich, 2015, Rate-independent detection of atrial fibrillation by statistical modeling of atrial activity, Biomed. Signal Process. Control, 18, 274, 10.1016/j.bspc.2015.01.007 · DOI
  21. Lake, 2010, Accurate estimation of entropy in very short physiological time series: the problem of atrial fibrillation detection in implanted ventricular devices, Am. J. Physiol., 300, H319
  22. Li, 2014a, A machine learning approach to multi-level ECG signal quality classification, Comput. Methods Prog. Biomed., 117, 435, 10.1016/j.cmpb.2014.09.002 · DOI · Paper page
  23. Li, 2014b, Ventricular fibrillation and tachycardia classification using a machine learning approach, IEEE Trans. Biomed. Eng., 61, 1607, 10.1109/TBME.2013.2275000 · DOI · Paper page
  24. Lim, 2017, Complexity and distribution of drivers in relation to duration of persistent atrial fibrillation, J. Am. Coll. Cardiol., 69, 1257, 10.1016/j.jacc.2017.01.014 · DOI · Paper page
  25. Linker, 2016, Accurate, automated detection of atrial fibrillation in ambulatory recordings, Cardiovascular Eng. Technol., 7, 182, 10.1007/s13239-016-0256-z · DOI
  26. Lip, 2016, Atrial fibrillation, Nat. Rev. Dis. Primers, 2, 16016, 10.1038/nrdp.2016.16 · DOI · Paper page
  27. Nademanee, 2004, A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate, J. Am. Coll. Cardiol., 43, 2044, 10.1016/j.jacc.2003.12.054 · DOI · Paper page
  28. Narayan, 2017, Ablation of focal impulses and rotational sources: what can be learned from differing procedural outcomes?, Curr. Cardiovascular Risk Rep., 11, 27, 10.1007/s12170-017-0552-7 · DOI
  29. Navoret, 2013, Detection of complex fractionated atrial electrograms using recurrence quantification analysis, IEEE Trans. Biomed. Eng., 60, 1975, 10.1109/TBME.2013.2247402 · doi:10.1109/tbme.2013.2247402
  30. Osowski, 2004, Support vector machine-based expert system for reliable heartbeat recognition, IEEE Trans. Biomed. Eng., 51, 582, 10.1109/TBME.2004.824138 · DOI · Paper page
  31. Oster, 2015, Impact of the presence of noise on RR interval-based atrial fibrillation detection, J. Electrocardiol., 48, 947, 10.1016/j.jelectrocard.2015.08.013 · DOI
  32. Park, 2009, Atrial fibrillation detection by heart rate variability in Poincare plot, Biomed. Eng., 8, 38
  33. Pathik, 2017, Transient rotor activity during prolonged three-dimensional phase mapping in human persistent atrial fibrillation, JACC Clin. Electrophysiol., 4, 72, 10.1016/j.jacep.2017.06.005 · DOI
  34. Petrėnas, 2015, Low-complexity detection of atrial fibrillation in continuous long-term monitoring, Comput. Biol. Med., 65, 184, 10.1016/j.compbiomed.2015.01.019 · DOI
  35. Piczak, 2015, Environmental sound classification with convolutional neural networks, 1, 10.1109/MLSP.2015.7324337 · DOI · Paper page
  36. Pürerfellner, 2014, P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors, Heart Rhythm, 11, 1575, 10.1016/j.hrthm.2014.06.006 · DOI
  37. Ródenas, 2015, Wavelet entropy automatically detects episodes of atrial fibrillation from single-lead electrocardiograms, Entropy, 17, 6179, 10.3390/e17096179 · DOI
  38. Sarkar, 2008, A detector for a chronic implantable atrial tachyarrhythmia monitor, IEEE Trans. Biomed. Eng., 55, 1219, 10.1109/TBME.2007.903707 · DOI · Paper page
  39. Srivastava, 2014, Dropout: a simple way to prevent neural networks from overfitting, J. Mach. Learn. Res., 15, 1929
  40. Tateno, 2001, Automatic detection of atrial fibrillation using the coefficient of variation and density histograms of RR and ΔRR intervals, Med. Biol. Eng. Comput., 39, 664, 10.1007/BF02345439 · DOI · Paper page
  41. Teijeiro, 2017, Arrhythmia classification from the abductive interpretation of short single-lead ECG records, 10.22489/CinC.2017.166-054 · DOI
  42. Xiong, 2017, Robust ECG signal classification for detection of atrial fibrillation using a novel neural network, Computing, 44, 1
  43. Yang, 2011, Multiscale recurrence quantification analysis of spatial cardiac vectorcardiogram signals, IEEE Trans. Biomed. Eng., 58, 339, 10.1109/TBME.2010.2063704 · DOI · Paper page
  44. Zabihi, 2017, Detection of atrial fibrillation in ECG hand-held devices using a random forest classifier, Computing, 44, 1
  45. Zhao, 2017, Three‐dimensional integrated functional, structural, and computational mapping to define the structural ‘fingerprints’ of heart‐specific atrial fibrillation drivers in human heart ex vivo, J. Am. Heart Assoc., 6, 10.1161/JAHA.117.005922 · DOI
  46. Zhao, 2015a, Integration of high-resolution optical mapping and 3-dimensional micro-computed tomographic imaging to resolve the structural basis of atrial conduction in the human heart, Circulation, 8, 1514, 10.1161/CIRCEP.115.003064 · doi:10.1161/circep.115.003064
  47. Zhao, 2015b, Progressive modification of rotors in persistent atrial fibrillation by stepwise linear ablation, HeartRhythm Case Rep., 1, 22, 10.1016/j.hrcr.2014.10.004 · doi:10.1016/j.hrcr.2014.10.004

Cited by

See all 161

Metadata

Authors
Xiong, Z., Nash, M. P., Cheng, E., Fedorov, V. V., Stiles, M. K., & Zhao, J.
Venue
Physiological Measurement
Published
2018-09-24
Volume
39
Issue
9
Pages
094006
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2887679614
Cited by
161
References
11
FWCI
14.28
Type
journal article
Language
en
Open access
bronze
Licence
Funders
  • National Institutes of Health (HL135109)
  • Health Research Council of New Zealand (16/385)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG signal classification for the detection of cardiac arrhythmias using a convolutional recurrent neural network. https://app.cochat.ai/papers/10.1088/1361-6579/aad9ed
The paper
Xiong, Z., Nash, M. P., Cheng, E., Fedorov, V. V., Stiles, M. K., & Zhao, J. (2018). ECG signal classification for the detection of cardiac arrhythmias using a convolutional recurrent neural network. Physiological Measurement. https://doi.org/10.1088/1361-6579/aad9ed

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.