Upper esophageal sphincter opening segmentation with convolutional recurrent neural networks in high resolution cervical auscultation

Open access
Khalifa, Yassin, Donohue, Cara, Coyle, James L., Sejdic, Ervin·2021·IEEE Journal of Biomedical and Health Informatics

Abstract

Upper esophageal sphincter is an important anatomical landmark of the swallowing process commonly observed through the kinematic analysis of radiographic examinations that are vulnerable to subjectivity and clinical feasibility issues. Acting as the doorway of esophagus, upper esophageal sphincter allows the transition of ingested materials from pharyngeal into esophageal stages of swallowing and a reduced duration of opening can lead to penetration/aspiration and/or pharyngeal residue. Therefore, in this study we consider a non-invasive high resolution cervical auscultation-based screening tool to approximate the human ratings of upper esophageal sphincter opening and closure. Swallows were collected from 116 patients and a deep neural network was trained to produce a mask that demarcates the duration of upper esophageal sphincter opening. The proposed method achieved more than 90% accuracy and similar values of sensitivity and specificity when compared to human ratings even when tested over swallows from an independent clinical experiment. Moreover, the predicted opening and closure moments surprisingly fell within an inter-human comparable error of their human rated counterparts which demonstrates the clinical significance of high resolution cervical auscultation in replacing ionizing radiation-based evaluation of swallowing kinematics.

Integrity signals

Registry

Crossref · 10.1109/jbhi.2020.3000057

Cites

75 of 75 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

0 of 36 cited sources checked · 0 supported · 0 flagged

  • Findingown data

    The study included 116 patients with suspected dysphagia (72 males, 44 females, mean age 62.7 ± 15.5) who underwent VFSS.

    “A total of one hundred and sixteen patients (72 males, 44 females, age: 62.7 ± 15.5) with suspected dysphagia resulting from a variety of diagnoses, underwent an oropharyngeal swallowing function evaluation by a speech language pathologist using VFSS at the University of Pittsburgh Medical Center Presbyterian Hospital (Pittsburgh, PA).”
    Quote in the paperSubstantial claim
  • Findingown data

    The final dataset included 224 single, 477 multiple, and 9 sequential swallows.

    “The final data included 224 single, 477 multiple, and 9 sequential swallows.”
    Quote in the paperNot a substantial claim
  • Findingown data

    The system performed similarly across subjects of different sex, age, and diagnosis.

    “These results were also achieved regardless of gender, age, or diagnosis of the subjects which assures the wide applicability of the system.”
    Quote in the paperSubstantial claim
  • Findingown data

    When tested on a separate set of swallows from a different participant group with different conditions, none of which were used in training, the system performed robustly.

    “The system also showed robust performance when applied to a completely independent set of swallows that were collected from a different group of participants with different conditions and never seen in the training dataset.”
    Quote in the paperSubstantial claim
  • Findingown data

    Performance was almost the same on a separate test set drawn from an ongoing clinical trial.

    “Moreover, the system showed nearly identical performance when used on an independent testing set from an ongoing clinical trial.”
    Quote in the paperSubstantial claim
  • May combine two claims. 35
  • Classified as probably not a substantial claim. 21
  • May combine two claims.

    Findingown data

    The method reached over 90% accuracy, with sensitivity and specificity close to human ratings, including on swallows from a separate clinical experiment.

    “The proposed method achieved more than 90% accuracy and similar values of sensitivity and specificity when compared to human ratings even when tested over swallows from an independent clinical experiment.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingown data

    Of the 116 patients, 15 had stroke and 101 had other medical conditions unrelated to stroke.

    “Of the sample, 15 patients were diagnosed with stroke while the remaining 101 patients were diagnosed with different medical conditions unrelated to stroke.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    The chosen network architecture was the most stable among tested configurations and fastest to converge, with the smallest number of parameters while achieving detection accuracy that did not sharply change when adding layers or increasing layer sizes.

    “The chosen architecture was found to be the most stable among the tested configurations and the fastest to converge. In other words, it included the smallest number of parameters to be optimized while achieving a detection accuracy that doesn’t sharply change when adding more layers or increasing the layer sizes.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    The study yielded 710 swallows (132 from stroke patients, 578 from other diagnoses) with average pharyngeal bolus transit duration 869.5±221 msec and average DUESO 604.9±150 msec.

    “This study yielded 710 swallows (132 from patients diagnosed with stroke and 578 from patients with other diagnoses) with an average duration of pharyngeal bolus transit of 869.5±221 msec and an average DUESO of 604.9±150 msec.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    In the independent test set, about 84% of swallows had UES opening detected within 100 ms, and about 66% had closure detected within that tolerance.

    “The results showed that UES opening and closure were detected within a 100 msec tolerance in around 84% and 66% of the swallows in the independent test set respectively.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In 82.6% of swallows, the opening of the UES fell within 100 ms of the human ratings, and in 90% it fell within 133 ms.

    “The comparison shows that for 82.6% of the swallows, the opening of UES was detected within a 100 msec (≈ 3 frames at 30 FPS) of the human ratings, and within a 133 msec (≈ 4 frames at 30 FPS) for 90% of the swallows (Fig. 5 (a)).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The proposed system achieved an average accuracy of 0.9039, sensitivity of 0.9145, and specificity of 0.9119 across all folds on the whole dataset.

    “The average accuracy of all folds across the whole dataset was 0.9039 with 0.9145 sensitivity and 0.9119 specificity.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The network's detections of UES opening and closure occurred, on average, 33 ms and 16 ms before the true events, respectively, as determined by swallow kinematic analysis.

    “On average, the network detected UES opening 33 msec earlier and closure 16 msec earlier than true opening and closure as measured by swallow kinematic analysis.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The system detected as much as 93.6% of the true DUESO, with few false positives or negatives, which appeared only at the edges of the DUESO.

    “Based on the results, we can clearly see that the proposed system accurately detected up to 93.6% of the actual DUESO with low rates of false positives and negatives occurring only at the borders of DUESO as shown in Fig. 4 (b).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingown data

    Validation participants reported no neurological disorder, no head or neck surgery, and no possibility of pregnancy.

    “Participants in this validation sample also had no history of neurological disorder, surgery to the head or neck region, or chance of being pregnant based on participant report.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    For the 50 swallows in the independent clinical experiment, the system achieved average per swallow accuracy 0.8880, sensitivity 0.8559, and specificity 0.9356.

    “for the 50 swallows, the system achieved an average per swallow accuracy of 0.8880, an average per swallow sensitivity of 0.8559, and an average per swallow specificity of 0.9356.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The clinical validation included 15 healthy adults (8 males, 7 females, mean age 63.7 ± 6.2) with no reported current or prior swallowing difficulties.

    “In order to evaluate the proposed system in a clinical environment, it was tested during the workflow of an ongoing clinical experiment performed on 15 (8 males, 7 females, age: 63.7 ± 6.2), community dwelling healthy adults who provided informed consent, and who had no reported current or prior swallowing difficulties.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The system achieved average accuracy above 90% of the swallow width and sensitivity above 91% of the DUESO width, with few false positives.

    “The proposed system yielded an average accuracy of more than 90% of the swallow width and more than 91% of the DUESO width (sensitivity) with a low false positive rate.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The system's testing accuracy on the independent set (0.888) was close to the validation accuracy on the original dataset (0.9035), and sensitivity and specificity were similar.

    “In terms of global measurements, the system achieved a close testing accuracy compared to the validation done through the folds of the original dataset (0.888 vs. 0.9035) and the same for sensitivity and specificity.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    For 72.3% of swallows, UES closure was detected by the network within 100 ms, and for over 80% it was detected within 133 ms.

    “Likewise, the network accurately detected UES closure within a 100 msec (≈ 3 frames at 30 FPS) for 72.3% of the swallows and within a 133 msec (≈ 4 frames at 30 FPS) for more than 80% of the swallows (Fig. 5 (b)).”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    UES opening permits ingested material to move from the pharynx into the esophagus.

    “UES opening enables food and liquid to enter the esophagus [19]–[22].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [19]–[22]

      Not checked in the free run.

  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductnone given

    Signals and video were acquired simultaneously with complete end-to-end synchronization.

    “Both signals and video were acquired simultaneously using LabView’s Signal Express (National Instruments, Austin, Texas) with a complete end-to-end synchronization.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    Sensor placement over the cricoid cartilage is reasonable because most pharyngeal swallowing activity arises from structures there, and this site has been reported to give the best signal-to-noise ratio for swallowing signals.

    “Attaching the sensors around the area of cricoid cartilage is logical given that most of the pharyngeal swallowing activity is produced by the anatomical structures present at this level and it has been reported to yield the best signal-to-noise ratio for the acquisition of swallowing signals [35], [36], [56], [57].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [35], [36], [56], [57]

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    UES opening is produced by hyolaryngeal excursion, bolus propulsion, and neural inhibitory relaxation of the UES.

    “UES opening is the product of hyolaryngeal excursion, bolus propulsion, and neural inhibitory relaxation of the UES itself [22], [23].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [22], [23]

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    HRCA has been used to monitor pharyngeal bolus propulsion from when the bolus passes the mandible until the UES closes.

    “HRCA has been used in multiple studies to monitor the pharyngeal bolus propulsion during swallowing from the moment the bolus passes the mandible till the UES closes [33]–[36].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [33]–[36]

      Not checked in the free run.

  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    RNNs have been extensively used for time series modeling because they can carry information from long contexts, selectively transfer information across time steps, and scale affordably compared with stochastic models and feed-forward networks.

    “Recurrent neural networks (RNNs) have been extensively employed for the time series modeling in the recent years, due to their capability of carrying information from arbitrarily long contexts, selective information transfer across time steps, and affordable scalability when compared to stochastic models and feed-forward networks [41]–[44].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [41]–[44]

      Not checked in the free run.

  • May combine two claims.

    Interpretationreasoning

    Because pharyngeal bolus propulsion, hyolaryngeal excursion, and UES closure are parts of the UES opening mechanism, HRCA signals have potential to detect UES opening.

    “The formerly mentioned events are all parts of the UES opening mechanism which proves the potential of HRCA signals in detection of UES opening.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Hyolaryngeal excursion has been investigated as the origin of HRCA signals and later used to track hyoid bone location during swallowing.

    “Furthermore, hyolaryngeal excursion has been investigated to be the origin of HRCA signals in many occasions [37]–[39], and later they were successfully used to actually track the location of the hyoid bone during swallowing [32].”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [37]–[39]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [32] Mao S, Zhang Z, Khalifa Y, Donohue C, Coyle JL, and Sejdić E,´ “ Neck sensor-supported hyoid bone movement tracking during swallowing,” Royal Society Open Science, vol. 6, no. 7, p. 181982, 7 2019. 31417694 PMC6689594 source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Reduced UES opening diameter, delayed opening onset, or premature closure shorten UES opening duration and can cause pharyngeal residue, which may enter the upper or lower airway and is a known risk factor for pneumonia and airway obstruction.

    “Reduced UES opening diameter, delayed onset of opening, or premature closure attenuate UES opening duration and can result in pharyngeal residue that in turn can enter the upper (laryngeal penetration) or lower (aspiration) airway, which are known risk factors for pneumonia and airway obstruction [23].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [23] Kim Y, Park T, Oommen E, and McCullough G, “ Upper esophageal sphincter opening during swallow in stroke survivors,” American Journal of Physical Medicine and Rehabilitation, vol. 94, no. 9, pp. 734– 739, 9 2015. 25768066 source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    The University of Pittsburgh IRB approved the study, and every patient gave informed consent, including consent to publish, before enrollment.

    “Permission for this study was granted by the institutional review board of the University of Pittsburgh and all participating patients provided informed consents including consent to publish before enrollment.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductcitation

    Dropout between layers and early stopping were used to control overfitting to training data.

    “The used architecture employed also dropout between layers as well as early stopping techniques to control the network from over-fitting to the training data [72].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [72] Srivastava N, Hinton G, Krizhevsky A, Sutskever I, and Salakhut-dinov R, “ Dropout: A simple way to prevent neural networks from over-fitting,” Journal of Machine Learning Research, vol. 15, no. 56, pp. 1929– 1958, 6 2014. source

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Three expert judges with training in swallow kinematics marked the first frame of UES opening and the first frame of UES closure in the segmented videos.

    “Three expert judges trained in swallow kinematic judgments, identified the video frame of first UES opening and the video frame of first UES closure in the segmented videos.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    The band-limiting filter cut-off frequencies were chosen to suppress most body sway components below 0.2 Hz and pass signal components containing the vast majority of energy.

    “The cut-off frequencies for the band-limiting filter were chosen so that most of body sway components below 0.2 Hz are suppressed and the signal components with the vast majority of energy are passed [35], [59]–[61].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [35], [59]–[61]

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Earlier work found that swallowing accelerometry signals have their peak energy below 100 Hz and a central frequency near or below 300 Hz.

    “A more intense down-sampling could have been adopted as previous studies reported that the frequency with the maximum energy for swallowing accelerometry signals occurs below 100 Hz and the central frequency almost below 300 Hz [35], [63]–[65].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [35], [63]–[65]

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    VFSS is the most frequent and best modality for clinical assessment of swallow kinematic events such as UES opening because it dynamically visualizes the UES during all swallow phases and gives exact opening and closing moments.

    “VFSSs are most frequently and actually the best modality to clinically assess swallow kinematic events such as UES opening, because of the ability to dynamically visualize the UES during all phases of the swallow and give exact estimates of the moments when UES opens and closes [19], [20].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [19], [20]

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The contact microphone was chosen to have a flat frequency response over the audible range, which was shown to pass most frequencies encountered during swallowing.

    “The contact microphone was chosen as well so that it produces a flat frequency response over the entire range of audible sounds which was proved to pass most of the frequencies encountered during swallowing [57]–[59].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [57]–[59]

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    UES dysfunction can result from neurological diseases that change UES relaxation timing and muscular traction delivery, or from impaired propulsive forces from the oropharyngeal pump.

    “UES dysfunction may occur due to neurological diseases that alter the timing of UES relaxation and the delivery of muscular traction forces that act to distend the relaxed UES during swallowing, or due to impaired propulsive forces applied by the oropharyngeal pump [20], [23].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [20], [23]

      Not checked in the free run.

  • May combine two claims.

    Study design and conductown data

    Raters kept intra- and inter-rater reliability above 0.xx during checks on 10% of swallows and were blinded to demographics, diagnosis, and bolus condition.

    “All raters maintained intra- and inter-rater reliability throughout measurements on 10% of swallows with ICC’s over 0.xx and were blinded to participant demographics and diagnosis and any bolus condition information.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    RNNs are efficient at modeling temporal contexts in time series and have been used for biomedical prediction tasks, but training RNNs on raw signals is very difficult because error signals propagate through many time steps.

    “RNNs are seemingly efficient in modeling temporal contexts in time series data and have been recently used to perform many biomedical prediction tasks of various complexities [45]–[48], but nevertheless using RNNs on raw signals is extremely hard to optimize because of the propagating of error signals through huge number of time steps [49], [50].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [45]–[48]

      Not checked in the free run.

    • cites [49], [50]

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    VFSS uses ionizing radiation, is unavailable or undesirable for many patients, is relatively expensive, and requires specialized instrumentation and trained clinicians, leaving many patients undiagnosed or inaccurately diagnosed and at ongoing risk of dysphagia-related complications.

    “However, VFSSs, which use ionizing radiation to produce radiographic images with full temporal resolution, are unavailable or undesirable to many patients, are relatively expensive, and require specialized instrumentation and trained clinicians to perform and interpret, leaving many patients undiagnosed or inaccurately diagnosed, and exposed to ongoing risk of dysphagia-related complications [19].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [19] Singh S and Hamdy S, “ The upper oesophageal sphincter,” Neurogastroenterology and Motility, vol. 17 Suppl 1, no. Suppl. 1, pp. 3– 12, 6 2005. 15836450 source

      Not checked in the free run.

  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductown data

    Swallows were split at random into ten equal groups; ten-fold cross-validation trained on nine groups and tested on the held-out group, repeated ten times.

    “The dataset was randomly divided into 10 equal subsets in terms of the number of swallows. A holdout method was repeated 10 times by training with 9 subsets and testing with the remaining one (10-fold cross validation).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    When anatomical diagnoses are suspected but imaging is not immediately available, HRCA may offer provisional information to guide care.

    “This point is crucial in that some causes of dysphagia are indeed anatomically based, however in situations in which such diagnoses are suspected and imaging is not available immediately, HRCA certainly shows promise toward providing interim information that can guide management.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Some dysphagia causes are anatomical.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    A single earlier study noted that the acoustic part of HRCA signals changes as the bolus moves through the UES.

    “One study also observed changes in the acoustic component of HRCA signals while the bolus passed through the UES [75].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [75] Moriniere S, Boiron M, Alison D, Makris P, and Beutter P, “ Origin of the sound components during pharyngeal swallowing in normal subjects,” Dysphagia, vol. 23, no. 3, pp. 267– 273, 9 2008. 18071792 source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The largest anterior-posterior UES diameter occurs 70 to 170 ms after the UES opens, with bolus size and other factors influencing the timing.

    “Maximal values of A-P UES diameter were found also to be reached after 70–170 msec of UES opening, depending on the bolus size and other factors [22].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [22] Cook IJ, Dodds WJ, Dantas RO, Massey B, Kern MK, Lang IM, Brasseur JG, and Hogan WJ, “ Opening mechanisms of the human upper esophageal sphincter,” American Journal of Physiology, vol. 257, no. 5 Pt 1, pp. G748– G759, 11 1989. 2596608 source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    The validation experiment used the same equipment and hardware as the main dataset.

    “The experimental setup of this clinical experiment relied on the same equipment and hardware used for the collection of the main dataset as shown in Fig. 1.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The accepted tolerance for human frame selection is approximately ±2.48 frames at 30 FPS.

    “The accepted tolerance for human frame selection ≈ ± 2.48 frames at 30 FPS [62].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [62] Lof GL and Robbins J, “ Test-retest variability in normal swallowing,” Dysphagia, vol. 4, no. 4, pp. 236– 242, 12 1990. 2209099 source

      Not checked in the free run.

  • May combine two claims.

    Premisenone given

    The clinical use of VF is limited by radiation exposure and its lack of availability beyond clinical care settings.

    “We have established the fact that UES opening can be best visualized using VF which is clinically impractical due to the delivered radiation doses and unavailability outside clinical care settings.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Certain earlier studies found that some HRCA signal features reach local peaks around the moments when the UES opens and closes.

    “Some of these studies reported the presence of localized maxima of some HRCA signal features at UES opening and closure times [40], [74].”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [40] Kurosu A, Coyle JL, Dudik JM, and Sejdić E,´ “ Detection of swallow kinematic events from acoustic high-resolution cervical auscultation signals in patients with stroke,” Archives of Physical Medicine and Rehabilitation, vol. 100, no. 3, pp. 501– 508, 3 2019. 30071198 PMC6402604 source

      Not checked in the free run.

    • cites [74] Perlman AL, He X, Barkmeier J, and Van Leer E, “ Bolus location associated with videofluoroscopic and respirodeglutometric events,” Journal of Speech, Language, and Hearing Research, vol. 48, no. 1, pp. 21– 33, 2 2005. 15938058 source

      Not checked in the free run.

  • May combine two claims.

    Interpretationown data

    The system's accurate DUESO detection extends to data it has never seen, indicating strong generalization.

    “This confirms that the high quality of DUESO detection can be carried over to completely unseen data and assures a high degree of generalization in the proposed system.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The Adam optimizer was used to train the network because it converges well without hyperparameter fine-tuning.

    “We used the Adam optimizer to train the network due to its superiority in convergence without fine tuning for hyper-parameters [73].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [73] Bengio Y, “ Practical recommendations for gradient-based training of deep architectures,” in Neural Networks: Tricks of the Trade, 2nd ed., ser. Lecture Notes in Computer Science, Montavon G, Orr GB, and Müller K-R, Eds. Springer, 2012, vol. 7700, pp. 437– 478.

      Not checked in the free run.

45 of 45
  • The paper relies on this without support.

    No prior study has used HRCA signals to measure the timing of UES opening and closure within a swallow.

    “While previous studies have monitored changes in HRCA signal features at the moments of UES opening and closure [40], no studies have used HRCA signals to measure the time of UES opening and closure within a swallow.”
  • The paper relies on this without support.

    Inter-human error in rating UES opening and closure is an acceptable benchmark for demonstrating clinical significance.

    “Moreover, the predicted opening and closure moments surprisingly fell within an inter-human comparable error of their human rated counterparts which demonstrates the clinical significance of high resolution cervical auscultation in replacing ionizing radiation-based evaluation of swallowing kinematics.”
  • The paper relies on this without support.

    The 710-swallow training dataset is representative enough that a model trained on it can generalize to an independent clinical sample.

    “Fifty swallows, selected randomly from this independent clinical experiment, were used to test the system for UES opening detection after being trained over the full 710 swallows dataset.”
  • The paper relies on this without support.

    UES opening is best seen with VF.

    “We have established the fact that UES opening can be best visualized using VF which is clinically impractical due to the delivered radiation doses and unavailability outside clinical care settings.”
  • The paper relies on this without support.

    Human ratings of swallowing kinematics can drift over time, so raters must maintain intra- and inter-rater reliability to keep error within tolerance.

    “Human ratings of swallow kinematic events can also drift over time and necessitates that raters maintain ongoing intra and inter-reliability over time to maintain an appropriate error tolerance.”
  • The paper relies on this without support.

    The proposed system is immune to changes over time.

    “Having an automated system that is capable of rating the swallowing kinematic events with a comparable human rater accuracy and impregnable to changes over time, is advantageous for swallowing analysis when imaging technology is unavailable, not feasible, or otherwise impractical for evaluating swallowing physiology.”
  • The paper relies on this without support.

    The accuracy of a physiological event detector cannot be assessed solely by comparison with human ratings.

    “It is important to bear in mind that the accuracy of any physiological event detector cannot be judged only through comparison with human ratings which are subject to error too.”
  • The paper relies on this without support.

    Some dysphagia causes are anatomical.

    “This point is crucial in that some causes of dysphagia are indeed anatomically based, however in situations in which such diagnoses are suspected and imaging is not available immediately, HRCA certainly shows promise toward providing interim information that can guide management.”
  • The paper relies on this without support.

    The UES plays a critical role in swallowing.

    “We have also demonstrated the critical rule that UES plays during swallowing and how monitoring its opening and closure will help identify the risks leading to unsafe swallowing.”
9 of 9

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Stroke was the most cited underlying disease, present in 12 studies.

    “with stroke being the most cited in 12 studies(16,18,21,22,27,32,36,40,46,48-51)”

    From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [46]

    The Materials and Methods section reports that 15 of 116 patients had a stroke diagnosis, so this paper supports including it among studies involving stroke. It does not compare underlying diseases across studies or establish that stroke was the most cited disease in 12 studies. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • In research, the most addressed pathologies in adults were predominantly neurological, with stroke highlighted.

    “In research, the most addressed pathologies in adults were predominantly related to the neurological area, with stroke being highlighted in several studies(16,21,22,24,27,36,40,46,48-51).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Abstract overstates accuracy on the independent test set

    Major

    The abstract says accuracy exceeded 90% even on the independent clinical experiment, but the reported accuracy for that set was 88.80%.

  • Conflicting counts of fully connected layers

    Minor

    The system design specifies four fully connected layers, including an output layer, whereas the conclusion describes the network as having three.

  • Two values reported for original-dataset accuracy

    Minor

    The results give an average accuracy of 0.9039 across folds, while the discussion uses 0.9035 for that validation result.

3 of 3

Cites

Flagged first, then by citations

10 of the 85 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E.
Affiliations
University of Pittsburgh (US)
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2021-02
Volume
25
Issue
2
Pages
493-503
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W3033575927
Cited by
49
References
85
Citations by year
2026: 3 · 2025: 8 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 9 · 2020: 5
FWCI
10.30
Type
journal article
Language
en
Open access
Locations
  • IEEE Journal of Biomedical and Health Informatics (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
Eunice Kennedy Shriver National Institute of Child Health & Human Development of the National Institutes of Health (R01HD092239, R01HD074819)
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Physiology › Voice and Speech Disorders
Keywords
upper esophageal sphincter, swallowing kinematics, convolutional recurrent neural network, dysphagia screening, penetration-aspiration, pharyngeal residue
MeSH terms
Auscultation, Deglutition, Humans, Manometry, Neural Networks, Computer, Esophageal Sphincter, Upper

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-04.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-04.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review