Automatic evaluation of fetal head biometry from ultrasound images using machine learning
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objective : Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are frequently used to evaluate gestational age and diagnose fetal central nervous system pathology. Because manual measurements are operator-dependent and time-consuming, much research is being actively conducted on automated methods. However, the existing automated methods are still not satisfactory in terms of accuracy and reliability, owing to difficulties dealing with various artefacts in ultrasound images. Approach : Using the proposed method, a labeled dataset containing 102 ultrasound images was used for training, and validation was performed with 70 ultrasound images. Main results : A success rate of 91.43% and 100% for HC and BPD estimations, respectively, and an accuracy of 87.14% for the plane acceptance check. Significance : This paper focuses on fetal head biometry and proposes a deep-learning-based method for estimating HC and BPD with a high degree of accuracy and reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
He, K., Gkioxari, G., Dollar, P., & Girshick, R. (2020) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2018.2844175 · Cited by 3,457
Attention-Based Models for Speech Recognition
Chorowski, J., Bahdanau, D., Serdyuk, D., Cho, K., & Bengio, Y. (2015) · arXiv · doi:10.48550/arxiv.1506.07503 · Cited by 2,021
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006 · cited 2×
“Li et al (2017) utilized a random forest classifier to localize the fetal head, then used phase symmetry and Ellifit (a least squares-based geometric ellipse fitting method) (Prasad et al 2013) to fit the HC ellipse for measurement. However, their method requires prior knowledge of the gestational age and ultrasound s…”
MethodHe, K., Gkioxari, G., Dollár, P., & Girshick, R. (2017) · arXiv · doi:10.48550/arxiv.1703.06870 · Cited by 406
FUIQA: Fetal Ultrasound Image Quality Assessment with Deep Convolutional Networks
Wu, L., Cheng, J.-Z., Li, S., Lei, B., Wang, T., & Ni, D. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2671898 · Cited by 242 · cited 1×
“Wu et al. [14] assessed image quality of fetal ultrasound image using two deep convolutional neural network (CNN) moedels.”
MethodCarneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205
Li, J., Wang, Y., Lei, B., Cheng, J.-Z., Qin, J., Wang, T., Li, S., & Ni, D. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2703890 · Cited by 120 · cited 1×
“biometric prarameters by classifying segment structures in ultrasound images. Although this approach showed some notable results, it requires complex, well-annotated data to train the tree. Li et al. [13] utilized a random forest classifier to licalize the fetal head, then used phase symmetry and Ellifit to fit the HC el…”
Method
Research works printed but not linked: 16
- Bennett, 1999, A method to detect and characterize ellipses using the Hough transform, IEEE Trans. Pattern Anal. Mach. Intell., 21, 652, 10.1109/34.777377 · DOI
- Chalana, 1996, Automatic fetal head measurements from sonographic images, Acad. Radiol., 3, 628, 10.1016/S1076-6332(96)80187-5 · DOI
- Cohen, 1960, A coefficient of agreement for nominal scales, Educ. Psychol. Meas., 20, 37, 10.1177/001316446002000104 · DOI · Paper page
- Espinoza, 2013, Does the use of automated fetal biometry improve clinical work flow efficiency?, J. Ultrasound Med., 32, 847, 10.7863/jum.2013.32.5.847 · DOI · Paper page
- Foi, 2014, Difference of gaussians revolved along elliptical paths for ultrasound fetal head segmentation, Comput. Med. Imaging Graph., 38, 774, 10.1016/j.compmedimag.2014.09.006 · DOI
- Hadlock, 1982, Fetal biparietal diameter: a critical re-evaluation of the relation to menstrual age by means of real-time ultrasound, J. Ultrasound Med., 1, 10.7863/jum.1982.1.3.97 · DOI · Paper page
- He, 2017, Mask R-CNN, 10.1109/ICCV.2017.322 · DOI · Paper page
- ISUOG (International Society of Ultrasound in Obstetrics & Gynecology Education Committee), 2007, Sonographic examination of the fetal central nervous system: guidelines for performing the ‘basic examination’ and the ‘fetal neurosonogram’, Ultrasound Obstetrics Gynecol., 29, 109, 10.1002/uog.3909 · DOI · Paper page
- LeCun, 1989, Backpropagation applied to hand-written zip code recognition, Neural Comput., 1, 541, 10.1162/neco.1989.1.4.541 · DOI · Paper page
- Lu, 2005, Automated fetal head detection and measurement in ultrasound images by iterative randomized Hough transform, Ultrasound Med. Biol., 31, 929, 10.1016/j.ultrasmedbio.2005.04.002 · DOI
- McLaughlin, 1998, Randomized Hough transform: improved ellipse detection with comparison, Pattern Recogn. Lett., 19, 299, 10.1016/S0167-8655(98)00010-5 · DOI · Paper page
- Prasad, 2013, Ellifit: an unconstrained non-iterative, least squares based geometric ellipse fitting method, Pattern Recogn., 46, 1449, 10.1016/j.patcog.2012.11.007 · DOI · Paper page
- Rueda, 2014, Evaluation and comparison of current fetal ultrasound image segmentation methods for biometric measurements: a grand challenge, IEEE Trans. Med. Imaging, 33, 797, 10.1109/TMI.2013.2276943 · DOI · Paper page
- Shepard, 1982, A standardized plane for biparietal diameter measurement, J. Ultrasound Med., 1, 10.7863/jum.1982.1.4.145 · DOI
- Xu, 1990, A new curve detection method: randomized Hough transform (RHT), Pattern Recogn. Lett., 11, 331, 10.1016/0167-8655(90)90042-Z · DOI · Paper page
- Yu, 2008, Fetal ultrasound image segmentation system and its use in fetal weight estimation, Med. Biol. Eng. Comput., 46, 1227, 10.1007/s11517-008-0407-y · DOI
Cited by
A review on deep-learning algorithms for fetal ultrasound-image analysis
Fiorentino, M. C., Villani, F. P., Di Cosmo, M., Frontoni, E., & Moccia, S. (2023) · Medical Image Analysis · doi:10.1016/j.media.2022.102629 · Cited by 200
“In [134], a region proposal network is used as post processing procedure once the fetal head is segmented by U-Net on polar transformed images.”
MethodUsing deep-learning algorithms to classify fetal brain ultrasound images as normal or abnormal
Xie, H. N., Wang, N., He, M., Zhang, L. H., Cai, H. M., Xian, J. B., Lin, M. F., Zheng, J., & Yang, Y. Z. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.21967 · Cited by 176
Machine Learning in Fetal Cardiology: What to Expect
Garcia-Canadilla, P., Sanchez-Martinez, S., Crispi, F., & Bijnens, B. (2020) · Fetal Diagnosis and Therapy · doi:10.1159/000505021 · Cited by 123
Artificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
Artificial Intelligence in Prenatal Ultrasound Diagnosis
He, F., Wang, Y., Xiu, Y., Zhang, Y., & Chen, L. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.729978 · Cited by 62
“Fetal factors—such as abnormalities, low contrast, speckle noise, boundary occlusion, or other artifacts—may affect intelligent detection and measurement; such conditions having been accounted for in the studies (22, 24, 26, 28).”
BackgroundMethod[Retracted] An Automated Deep Learning Model for the Cerebellum Segmentation from Fetal Brain Images
Sreelakshmy, R., Titus, A., Sasirekha, N., Logashanmugam, E., Begam, R. B., Ramkumar, G., & Raju, R. (2022) · BioMed Research International · doi:10.1155/2022/8342767 · Cited by 51
“Kim et al. [22] have developed a DL-based approach for calculating biparietal diameter (BPD) and head circumference (HC) with excellent reliability and accuracy.”
RetractedUse of artificial intelligence in obstetrics: Not quite ready for prime time
Sarno, L., Neola, D., Carbone, L., Saccone, G., Carlea, A., Miceli, M., Iorio, G. G., Mappa, I., Rizzo, G., Girolamo, R. D., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2022.100792 · Cited by 47
Automated ultrasound assessment of amniotic fluid index using deep learning
Cho, H. C., Sun, S., Min Hyun, C., Kwon, J.-Y., Kim, B., Park, Y., & Seo, J. K. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101951 · Cited by 43
Self-citationDevelopment of a Machine Learning Model for Sonographic Assessment of Gestational Age
Lee, C., Willis, A., Chen, C., Sieniek, M., Watters, A., Stetson, B., Uddin, A., Wong, J., Pilgrim, R., Chou, K., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.48685 · Cited by 42
DeepGA for automatically estimating fetal gestational age through ultrasound imaging
Dan, T., Chen, X., He, M., Guo, H., He, X., Chen, J., Xian, J., Hu, Y., Zhang, B., Wang, N., et al. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102453 · Cited by 25
Recognition of Fetal Facial Ultrasound Standard Plane Based on Texture Feature Fusion
Wang, X., Liu, Z., Du, Y., Diao, Y., Liu, P., Lv, G., & Zhang, H. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/6656942 · Cited by 23
“Besides, in recent years, researches on the measurement of biological parameters [36 – 38] and the detection of vital anatomical structures [39, 40] of fetal ultrasound images have emerged one after another.”
BackgroundZhang, J., Petitjean, C., & Ainouz, S. (2022) · Journal of Imaging · doi:10.3390/jimaging8020023 · Cited by 21
“Other approaches build upon deep segmentation models also in a two-step process, contour prediction, and ellipse fitting [15].”
Method
Metadata
- Authors
- Kim, H. P., Lee, S. M., Kwon, J.-Y., Park, Y., Kim, K. C., & Seo, J. K.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2019-06-01
- Volume
- 40
- Issue
- 6
- Pages
- 065009
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2963417582
- Cited by
- 54
- References
- 9
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 31 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 31 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.