OBJECTIVE: To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND: Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physical activity and nocturnal cardiovascular measurements. Ring users can follow their autonomic nervous system responses to their daily behavior based on nightly changes in HR and HRV, and adjust their behavior accordingly after self-reflection. As wearable photoplethysmogram (PPG) can be disrupted by several confounding influences, it is crucial to demonstrate the accuracy of ring measurements. APPROACH: Nocturnal HR and HRV were assessed in 49 adults with simultaneous measurements from the Oura ring and the gold standard ECG measurement. Female and male participants with a wide age range (15-72 years) and physical activity status were included. Regression analysis between ECG and the ring outcomes was performed. MAIN RESULTS: = 0.869 ± 0.098 and 0.765 ± 0.178 in HR and HRV, respectively). SIGNIFICANCE: Present findings indicate high validity of the Oura ring in the assessment of nocturnal HR and HRV in healthy adults. The results show the utility of this miniaturised device as a lifestyle management tool in long-term settings. High quality PPG signal results prompt future studies utilizing ring PPG towards clinically relevant health outcomes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/ab840a

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 25 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. Kinnunen H O 1997 Quality of ambulatory heart rate variability data and artifact correction Master's Thesis University of Oulu

Cited by

Sorted by citations

Authors
Kinnunen, H., Rantanen, A., Kenttä, T., & Koskimäki, H.
Affiliations
  • University of Oulu (FI)
  • Oulu University Hospital (FI)
Corresponding author
Kinnunen, Hannu
Venue
Physiological Measurement
Published
2020-04-01
Volume
41
Issue
4
Pages
04NT01
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W3013227193
Cited by
184
References
25
Citations by year
2026: 26 · 2025: 36 · 2024: 35 · 2023: 29 · 2022: 25 · 2021: 27 · 2020: 6
FWCI
6.83
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Tauno Tönningin Säätiö (20190151)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
Oura Ring, photoplethysmography, heart rate variability, resting heart rate, nocturnal heart rate, wearable devices, ECG validation, autonomic nervous system, cardiovascular health, recovery assessment, lifestyle management
MeSH terms
Adolescent, Adult, Aged, Electrocardiography, Feasibility Studies, Female, Heart Rate, Humans, Male, Middle Aged, Monitoring, Physiologic, Signal Processing, Computer-Assisted, Time Factors, Photoplethysmography, Recovery of Function, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review